Literature DB >> 16690436

A gradient feature weighted Minimax algorithm for registration of multiple portal images to 3DCT volumes in prostate radiotherapy.

Sudhakar Chelikani1, Kailasnath Purushothaman, Jonathan Knisely, Zhe Chen, Ravinder Nath, Ravi Bansal, James Duncan.   

Abstract

PURPOSE: To develop an accurate, fast, and robust algorithm for registering portal and computed tomographic (CT) images for radiotherapy using a combination of sparse and dense field data that complement each other. METHODS AND MATERIALS: Gradient Feature Weighted Minimax (GFW Minimax) method was developed to register multiple portal images to three-dimensional CT images. Its performance was compared with that of three others: Minimax, Mutual Information, and Gilhuijs' method. Phantom and prostate cancer patient images were used. Effects of registration errors on tumor control probability (TCP) and normal tissue complication probability (NTCP) were investigated as a relative measure.
RESULTS: Registration of four portals to CTs resulted in 30% lower error when compared with registration with two portals. Computation time increased by nearly 50%. GFW Minimax performed the best, followed by Gilhuijs' method, the Minimax method, and Mutual Information.
CONCLUSIONS: Using four portals instead of two lowered the registration error. Reduced fields of view images with full feature sets gave similar results in shorter times as full fields of view images. In clinical situations where soft tissue targets are of importance, GFW Minimax algorithm was significantly more accurate and robust. With registration errors lower than 1 mm, margins may be scaled down to 4 mm without adversely affecting TCP and NTCP.

Entities:  

Mesh:

Year:  2006        PMID: 16690436      PMCID: PMC2791048          DOI: 10.1016/j.ijrobp.2005.12.032

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  28 in total

1.  A minimax entropy registration framework for patient setup verification in radiotherapy.

Authors:  R Bansal; L Staib; Z Chen; A Rangarajan; J Knisely; R Nath; J Duncan
Journal:  Comput Aided Surg       Date:  1999

2.  Inclusion of geometric uncertainties in treatment plan evaluation.

Authors:  Marcel van Herk; Peter Remeijer; Joos V Lebesque
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-04-01       Impact factor: 7.038

3.  Survival and cell cycle kinetics of human prostate cancer cell lines after single- and multifraction exposures to ionizing radiation.

Authors:  Susan L Scott; Paul H Gumerlock; Laurel Beckett; Yueju Li; Zelanna Goldberg
Journal:  Int J Radiat Oncol Biol Phys       Date:  2004-05-01       Impact factor: 7.038

4.  A grey-level image alignment algorithm for registration of portal images and digitally reconstructed radiographs.

Authors:  D H Hristov; B G Fallone
Journal:  Med Phys       Date:  1996-01       Impact factor: 4.071

5.  An image correlation procedure for digitally reconstructed radiographs and electronic portal images.

Authors:  L Dong; A L Boyer
Journal:  Int J Radiat Oncol Biol Phys       Date:  1995-12-01       Impact factor: 7.038

6.  Implementation of a model for estimating tumor control probability for an inhomogeneously irradiated tumor.

Authors:  A Niemierko; M Goitein
Journal:  Radiother Oncol       Date:  1993-11       Impact factor: 6.280

7.  Automatic on-line inspection of patient setup in radiation therapy using digital portal images.

Authors:  K G Gilhuijs; M van Herk
Journal:  Med Phys       Date:  1993 May-Jun       Impact factor: 4.071

8.  Analysis of biopsy outcome after three-dimensional conformal radiation therapy of prostate cancer using dose-distribution variables and tumor control probability models.

Authors:  S Levegrün; A Jackson; M J Zelefsky; E S Venkatraman; M W Skwarchuk; W Schlegel; Z Fuks; S A Leibel; C C Ling
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-07-15       Impact factor: 7.038

9.  Patient setup error measurement using 3D intensity-based image registration techniques.

Authors:  Sébastien Clippe; David Sarrut; Claude Malet; Serge Miguet; Chantal Ginestet; Christian Carrie
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-05-01       Impact factor: 7.038

10.  A comparison of four patient immobilization devices in the treatment of prostate cancer patients with three dimensional conformal radiotherapy.

Authors:  P Y Song; M Washington; F Vaida; R Hamilton; D Spelbring; B Wyman; J Harrison; G T Chen
Journal:  Int J Radiat Oncol Biol Phys       Date:  1996-01-01       Impact factor: 7.038

View more
  7 in total

1.  A frequency-based approach to locate common structure for 2D-3D intensity-based registration of setup images in prostate radiotherapy.

Authors:  Reshma Munbodh; Zhe Chen; David A Jaffray; Douglas J Moseley; Jonathan P S Knisely; James S Duncan
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

2.  A CONSTRAINED NON-RIGID REGISTRATION ALGORITHM FOR APPLICATION IN PROSTATE RADIOTHERAPY.

Authors:  W H Greene; S Chelikani; X Papademetris; J P S Knisely; J Duncan
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2007

3.  TRACKING ORGAN OVERLAP FOR A CONSTRAINED NON-RIGID REGISTRATION ALGORITHM.

Authors:  W H Greene; S Chelikani; X Papademetris; L H Staib; J P S Knisely; J Duncan
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2008

4.  An integrated approach to segmentation and nonrigid registration for application in image-guided pelvic radiotherapy.

Authors:  Chao Lu; Sudhakar Chelikani; Xenophon Papademetris; Jonathan P Knisely; Michael F Milosevic; Zhe Chen; David A Jaffray; Lawrence H Staib; James S Duncan
Journal:  Med Image Anal       Date:  2011-05-20       Impact factor: 8.545

5.  A unified framework for joint segmentation, nonrigid registration and tumor detection: application to MR-guided radiotherapy.

Authors:  Chao Lu; Sudhakar Chelikani; James S Duncan
Journal:  Inf Process Med Imaging       Date:  2011

6.  Simultaneous nonrigid registration, segmentation, and tumor detection in MRI guided cervical cancer radiation therapy.

Authors:  Chao Lu; Sudhakar Chelikani; David A Jaffray; Michael F Milosevic; Lawrence H Staib; James S Duncan
Journal:  IEEE Trans Med Imaging       Date:  2012-02-06       Impact factor: 10.048

7.  Constrained non-rigid registration for use in image-guided adaptive radiotherapy.

Authors:  W H Greene; S Chelikani; K Purushothaman; J P S Knisely; Z Chen; X Papademetris; L H Staib; J S Duncan
Journal:  Med Image Anal       Date:  2009-07-16       Impact factor: 8.545

  7 in total