Literature DB >> 16686415

Tri-polar concentric ring electrode development for laplacian electroencephalography.

Walter G Besio1, Kanthaiah Koka, Rajesh Aakula, Weizhong Dai.   

Abstract

Brain activity generates electrical potentials that are spatio-temporal in nature. Electroencephalography (EEG) is the least costly and most widely used noninvasive technique for diagnosing many brain problems. It has high temporal resolution, but lacks high spatial resolution. In an attempt to increase the spatial selectivity, researchers introduced a bipolar electrode configuration utilizing a five-point finite difference method (FPM) and others applied a quasi-bipolar (tri-polar with two elements shorted) concentric electrode configuration. To further increase the spatial resolution, the authors report on a tri-polar concentric electrode configuration for approximating the analytical Laplacian based on a nine-point finite difference method (NPM). For direct comparison, the FPM, quasi-bipolar method (a hybrid NPM), and NPM were calculated over a 400 x 400 mesh with 1/400 spacing using a computer model. A closed-form analytical computer model was also developed to evaluate and compare the properties of concentric bipolar, quasi-bipolar, and tri-polar electrode configurations, and the results were verified with tank experiments. The tri-polar configuration and the NPM were found to have significantly improved accuracy in Laplacian estimation and localization. Movement-related potential (MRP) signals were recorded from the left prefrontal lobes on the scalp of human subjects while they performed fast repetitive movements. Disc, bipolar, quasi-bipolar, and tri-polar electrodes were used. MRP signals were plotted for all four electrode configurations. The signal-to-noise ratio and spatial selectivity of the MRP signals acquired with the tri-polar electrode configuration were significantly better than the other configurations.

Entities:  

Mesh:

Year:  2006        PMID: 16686415     DOI: 10.1109/TBME.2005.863887

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  12 in total

1.  Toward a noninvasive automatic seizure control system in rats with transcranial focal stimulations via tripolar concentric ring electrodes.

Authors:  Oleksandr Makeyev; Xiang Liu; Hiram Luna-Munguía; Gabriela Rogel-Salazar; Samuel Mucio-Ramirez; Yuhong Liu; Yan L Sun; Steven M Kay; Walter G Besio
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2012-07       Impact factor: 3.802

2.  Effects of transcranial focal electrical stimulation via tripolar concentric ring electrodes on pentylenetetrazole-induced seizures in rats.

Authors:  W G Besio; O Makeyev; A Medvedev; K Gale
Journal:  Epilepsy Res       Date:  2013-01-03       Impact factor: 3.045

3.  Improving the accuracy of Laplacian estimation with novel multipolar concentric ring electrodes.

Authors:  Oleksandr Makeyev; Quan Ding; Walter G Besio
Journal:  Measurement (Lond)       Date:  2016-02-01       Impact factor: 3.927

4.  High-Frequency Oscillations Recorded on the Scalp of Patients With Epilepsy Using Tripolar Concentric Ring Electrodes.

Authors:  Walter G Besio; Iris E Martínez-Juárez; Oleksandr Makeyev; John N Gaitanis; Andrew S Blum; Robert S Fisher; Andrei V Medvedev
Journal:  IEEE J Transl Eng Health Med       Date:  2014-06-30       Impact factor: 3.316

5.  Noninvasive transcranial focal stimulation via tripolar concentric ring electrodes lessens behavioral seizure activity of recurrent pentylenetetrazole administrations in rats.

Authors:  Oleksandr Makeyev; Hiram Luna-Munguía; Gabriela Rogel-Salazar; Xiang Liu; Walter G Besio
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2012-06-05       Impact factor: 3.802

6.  Non-invasive auditory brainstem responses to FM sweeps in awake big brown bats.

Authors:  Andrea Megela Simmons; Amaro Tuninetti; Brandon M Yeoh; James A Simmons
Journal:  J Comp Physiol A Neuroethol Sens Neural Behav Physiol       Date:  2022-06-28       Impact factor: 2.389

7.  The effects of concentric ring electrode electrical stimulation on rat skin.

Authors:  W Besio; V Sharma; J Spaulding
Journal:  Ann Biomed Eng       Date:  2010-01-20       Impact factor: 3.934

8.  Automatic seizure detection in rats using Laplacian EEG and verification with human seizure signals.

Authors:  Amal Feltane; G Faye Boudreaux-Bartels; Walter Besio
Journal:  Ann Biomed Eng       Date:  2012-10-17       Impact factor: 3.934

9.  Improving the Accuracy of Laplacian Estimation with Novel Variable Inter-Ring Distances Concentric Ring Electrodes.

Authors:  Oleksandr Makeyev; Walter G Besio
Journal:  Sensors (Basel)       Date:  2016-06-10       Impact factor: 3.576

10.  Solving the general inter-ring distances optimization problem for concentric ring electrodes to improve Laplacian estimation.

Authors:  Oleksandr Makeyev
Journal:  Biomed Eng Online       Date:  2018-08-30       Impact factor: 2.819

View more