Literature DB >> 16684041

Risk factors for requirement of permanent pacemaker implantation after aortic valve replacement.

Hasan Basri Erdogan1, Nihan Kayalar, Hasan Ardal, Suat Nail Omeroglu, Kaan Kirali, Mustafa Guler, Esat Akinci, Cevat Yakut.   

Abstract

BACKGROUND: The aim of this study was to evaluate the frequency of requirement for permanent pacing and related risk factors after aortic valve replacement.
METHODS: Among 465 patients operated between 1994 and 2004, 19(4.1%) patients with a mean age 49.9 +/- 17.2 years required the implantation of a permanent pacemaker. Eleven of them were female (57.9%). The main indication was aortic stenosis (89.5%). Severe annular calcification was documented in 78.9% of them, and the aortic valve was bicuspid in 57.9%.
RESULTS: Risk factors for permanent pacing after aortic valve replacement (AVR) identified by univariate analysis were female sex, hypertension, preoperative ejection fraction, aortic stenosis, annular calcification, bicuspid aorta, presence of right bundle branch block (RBBB) or left bundle branch block (LBBB), prolonged aortic cross-clamp and perfusion times, and preoperative use of calcium channel blockers. Multivariate analysis showed that female sex (p = 0.01, OR; 5.21, 95% CI: 1.48-18.34), annular calcification (p < 0.001, OR; 0.05, 95% CI: 0.01-0.24), bicuspid aortic valve (p = 0.02, OR; 0.24, 95% CI: 0.07-0.84), presence of RBBB (p = 0.009, OR; 0.03, 95% CI: 0.003-0.44) or LBBB (p = 0.01, OR; 0.13, 95% CI: 0.02-0.69), hypertension (p = 0.03, OR; 0.22, 95%CI: 0.05-0.89), and total perfusion time (p = 0.002, OR; 1.05, 95% CI: 1.01-1.08) were associated risk factors.
CONCLUSION: Irreversible atrioventricular block requiring a permanent pacemaker implantation is an uncommon complication after AVR. Risk factors are annular calcification, bicuspid aorta, female sex, presence of RBBB or LBBB, prolonged total perfusion time, and hypertension.

Entities:  

Mesh:

Year:  2006        PMID: 16684041     DOI: 10.1111/j.1540-8191.2006.00216.x

Source DB:  PubMed          Journal:  J Card Surg        ISSN: 0886-0440            Impact factor:   1.620


  15 in total

1.  Subclavicular screwed wire transient pacing to increase safety of transcatheter aortic valve implantation with the CoreValve system.

Authors:  Thomas Cuisset; Jacques Quilici
Journal:  J Cardiol Cases       Date:  2011-04-06

2.  Need for Permanent Pacemaker After Surgical Aortic Valve Replacement Reduces Long-Term Survival.

Authors:  J Hunter Mehaffey; Nathan S Haywood; Robert B Hawkins; John A Kern; Nicholas R Teman; Irving L Kron; Leora T Yarboro; Gorav Ailawadi
Journal:  Ann Thorac Surg       Date:  2018-03-22       Impact factor: 4.330

3.  Incidence rate and predictors of permanent pacemaker implantation after transcatheter aortic valve implantation with self-expanding CoreValve prosthesis.

Authors:  Valeria Calvi; Sergio Conti; Giusi Paola Pruiti; Davide Capodanno; Euglena Puzzangara; Donatella Tempio; Angelo Di Grazia; Gian Paolo Ussia; Corrado Tamburino
Journal:  J Interv Card Electrophysiol       Date:  2011-11-26       Impact factor: 1.900

4.  Ongoing requirement for pacing post-transcatheter aortic valve implantation and surgical aortic valve replacement.

Authors:  Alexander D Simms; Andrew J Hogarth; Elizabeth A Hudson; Victoria L Worsnop; Daniel J Blackman; David J O'Regan; Muzahir H Tayebjee
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-04-25

Review 5.  New conduction abnormalities after TAVI--frequency and causes.

Authors:  Robert M van der Boon; Rutger-Jan Nuis; Nicolas M Van Mieghem; Luc Jordaens; Josep Rodés-Cabau; Ron T van Domburg; Patrick W Serruys; Robert H Anderson; Peter P T de Jaegere
Journal:  Nat Rev Cardiol       Date:  2012-05-01       Impact factor: 32.419

6.  Conduction disorders after aortic valve replacement: what is the real impact of sutureless and rapid deployment valves?

Authors:  Paolo Berretta; Luca Montecchiani; Fabio Vagnarelli; Mariano Cefarelli; Jacopo Alfonsi; Carlo Zingaro; Filippo Capestro; Michele D Pierri; Alessandro D'alfonso; Marco Di Eusanio
Journal:  Ann Cardiothorac Surg       Date:  2020-09

7.  Predictors and frequency of conduction disturbances after open-heart surgery.

Authors:  Zahra Emkanjoo; Mansour Mirza-Ali; Abollfath Alizadeh; Saied Hosseini; Mohammad Vahid Jorat; Mohammad Hossein Nikoo; Mohammad Ali Sadr-Ameli
Journal:  Indian Pacing Electrophysiol J       Date:  2008-02-01

8.  Incidence and Risk Factors for Permanent Pacemaker Implantation Following Mitral or Aortic Valve Surgery.

Authors:  Gil Moskowitz; Kimberly N Hong; Gennaro Giustino; A Marc Gillinov; Gorav Ailawadi; Joseph J DeRose; Alexander Iribarne; Alan J Moskowitz; Annetine C Gelijns; Natalia N Egorova
Journal:  J Am Coll Cardiol       Date:  2019-11-26       Impact factor: 24.094

9.  Pacemaker dependency after isolated aortic valve replacement: do conductance disorders recover over time?

Authors:  Hassina Baraki; Ammar Al Ahmad; Stefan Jeng-Singh; Shunsuke Saito; Jan Dieter Schmitto; Bernhard Fleischer; Axel Haverich; Ingo Kutschka
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-01-08

Review 10.  Atrioventricular and intraventricular block after transcatheter aortic valve implantation.

Authors:  Jane J Lee; Nora Goldschlager; Vaikom S Mahadevan
Journal:  J Interv Card Electrophysiol       Date:  2018-06-24       Impact factor: 1.900

View more