Third-generation blood pumps with mechanical noncontact magnetic bearings.

Hideo Hoshi1, Tadahiko Shinshi, Setsuo Takatani.   

Abstract

This article reviews third-generation blood pumps, focusing on the magnetic-levitation (maglev) system. The maglev system can be categorized into three types: (i) external motor-driven system, (ii) direct-drive motor-driven system, and (iii) self-bearing or bearingless motor system. In the external motor-driven system, Terumo (Ann Arbor, MI, U.S.A.) DuraHeart is an example where the impeller is levitated in the axial or z-direction. The disadvantage of this system is the mechanical wear in the mechanical bearings of the external motor. In the second system, the impeller is made into the rotor of the motor, and the magnetic flux, through the external stator, rotates the impeller, while the impeller levitation is maintained through another electromagnetic system. The Berlin Heart (Berlin, Germany) INCOR is the best example of this principle where one-axis control combination with hydrodynamic force achieves high performance. In the third system, the stator core is shared by the levitation and drive coil to make it as if the bearing does not exist. Levitronix CentriMag (Zürich, Switzerland), which appeared recently, employs this concept to achieve stable and safe operation of the extracorporeal system that can last for a duration of 14 days. Experimental systems including HeartMate III (Thoratec, Woburn, MA, U.S.A.), HeartQuest (WorldHeart, Ottawa, ON, Canada), MagneVAD (Gold Medical Technologies, Valhalla, NY, U.S.A.), MiTiHeart (MiTi Heart, Albany, NY, U.S.A.), Ibaraki University's Heart (Hitachi, Japan) and Tokyo Medical and Dental University/Tokyo Institute of Technology's disposable and implantable maglev blood pumps are also reviewed. In reference to second-generation blood pumps, such as the Jarvik 2000 (Jarvik Heart, New York, NY, U.S.A.), which is showing remarkable achievement, a question is raised whether a complicated system such as the maglev system is really needed. We should pay careful attention to future clinical outcomes of the ongoing clinical trials of the second-generation devices before making any further remarks. What is best for patients is the best for everyone. We should not waste any efforts unless they are actually needed to improve the quality of life of heart-failure patients.

Entities:  

Mesh:

Year:  2006        PMID: 16683949     DOI: 10.1111/j.1525-1594.2006.00222.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  24 in total

1.  Homopolar Bearingless Slice Motor with Flux-biasing Halbach Arrays.

Authors:  Minkyun Noh; David L Trumper
Journal:  IEEE Trans Ind Electron       Date:  2019-09-25       Impact factor: 8.236

Review 2.  The use of computational fluid dynamics in the development of ventricular assist devices.

Authors:  Katharine H Fraser; M Ertan Taskin; Bartley P Griffith; Zhongjun J Wu
Journal:  Med Eng Phys       Date:  2010-11-13       Impact factor: 2.242

3.  Optimization of a Hybrid Magnetic Bearing for a Magnetically Levitated Blood Pump via 3-D FEA.

Authors:  Shanbao Cheng; Mark W Olles; Aaron F Burger; Steven W Day
Journal:  Mechatronics (Oxf)       Date:  2011-10       Impact factor: 3.498

4.  The future of adult cardiac assist devices: novel systems and mechanical circulatory support strategies.

Authors:  Carlo R Bartoli; Robert D Dowling
Journal:  Cardiol Clin       Date:  2011-11       Impact factor: 2.213

5.  Estimation of changes in dynamic hydraulic force in a magnetically suspended centrifugal blood pump with transient computational fluid dynamics analysis.

Authors:  Toru Masuzawa; Akiko Ohta; Nobuatu Tanaka; Yi Qian; Tomonori Tsukiya
Journal:  J Artif Organs       Date:  2009-09-19       Impact factor: 1.731

6.  Development of a miniaturized mass-flow meter for an axial flow blood pump based on computational analysis.

Authors:  Ryo Kosaka; Masahiro Nishida; Osamu Maruyama; Takashi Yamane
Journal:  J Artif Organs       Date:  2011-05-03       Impact factor: 1.731

7.  Passive magnetic bearing in the 3rd generation miniature axial flow pump-the valvo pump 2.

Authors:  Eiji Okamoto; Yuya Ishida; Tetsuya Yano; Yoshinori Mitamura
Journal:  J Artif Organs       Date:  2014-11-19       Impact factor: 1.731

Review 8.  Treatment strategies for patients with an INTERMACS I profile.

Authors:  Walid K Abu Saleh; Odeaa Al Jabbari; Ashrith Guha; Matthias Loebe; Brian A Bruckner
Journal:  Methodist Debakey Cardiovasc J       Date:  2015 Jan-Mar

9.  Novel temporary left ventricular assist system with hydrodynamically levitated bearing pump for bridge to decision: initial preclinical assessment in a goat model.

Authors:  Satoru Kishimoto; Yoshiaki Takewa; Tomonori Tsukiya; Toshihide Mizuno; Kazuma Date; Hirohito Sumikura; Yutaka Fujii; Kentaro Ohnuma; Konomi Togo; Nobumasa Katagiri; Noritsugu Naito; Yuichiro Kishimoto; Yoshinobu Nakamura; Motonobu Nishimura; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2017-09-12       Impact factor: 1.731

10.  A mini axial and a permanent maglev radial heart pump.

Authors:  Kun-Xi Qian; Wei-Min Ru; Hao Wang; Teng Jing
Journal:  Open Biomed Eng J       Date:  2007-05-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.