Development of a miniaturized mass-flow meter for an axial flow blood pump based on computational analysis.

Ryo Kosaka1, Masahiro Nishida, Osamu Maruyama, Takashi Yamane.   

Abstract

In order to monitor the condition of patients with implantable left ventricular assist systems (LVAS), it is important to measure pump flow rate continuously and noninvasively. However, it is difficult to measure the pump flow rate, especially in an implantable axial flow blood pump, because the power consumption has neither linearity nor uniqueness with regard to the pump flow rate. In this study, a miniaturized mass-flow meter for discharged patients with an implantable axial blood pump was developed on the basis of computational analysis, and was evaluated in in-vitro tests. The mass-flow meter makes use of centrifugal force produced by the mass-flow rate around a curved cannula. An optimized design was investigated by use of computational fluid dynamics (CFD) analysis. On the basis of the computational analysis, a miniaturized mass-flow meter made of titanium alloy was developed. A strain gauge was adopted as a sensor element. The first strain gauge, attached to the curved area, measured both static pressure and centrifugal force. The second strain gauge, attached to the straight area, measured static pressure. By subtracting the output of the second strain gauge from the output of the first strain gauge, the mass-flow rate was determined. In in-vitro tests using a model circulation loop, the mass-flow meter was compared with a conventional flow meter. Measurement error was less than ±0.5 L/min and average time delay was 0.14 s. We confirmed that the miniaturized mass-flow meter could accurately measure the mass-flow rate continuously and noninvasively.

Entities:  

Mesh:

Year:  2011        PMID: 21537972     DOI: 10.1007/s10047-011-0569-5

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  12 in total

1.  HeartMate II left ventricular assist system: from concept to first clinical use.

Authors:  B P Griffith; R L Kormos; H S Borovetz; K Litwak; J F Antaki; V L Poirier; K C Butler
Journal:  Ann Thorac Surg       Date:  2001-03       Impact factor: 4.330

2.  An ultradurable and compact rotary blood pump with a magnetically suspended impeller in the radial direction.

Authors:  T Masuzawa; T Kita; Y Okada
Journal:  Artif Organs       Date:  2001-05       Impact factor: 3.094

3.  Flow rate and pressure head estimation in a centrifugal blood pump.

Authors:  Akio Funakubo; Shahriar Ahmed; Ichiro Sakuma; Yasuhiro Fukui
Journal:  Artif Organs       Date:  2002-11       Impact factor: 3.094

4.  First clinical experience with the DeBakey VAD continuous-axial-flow pump for bridge to transplantation.

Authors:  G M Wieselthaler; H Schima; M Hiesmayr; R Pacher; G Laufer; G P Noon; M DeBakey; E Wolner
Journal:  Circulation       Date:  2000-02-01       Impact factor: 29.690

5.  In vivo test of pressure head and flow rate estimation in a continuous-flow artificial heart.

Authors:  Akira Tanaka; Makoto Yoshizawa; Ken-ichi Abe; Hiroshi Takeda; Tomoyuki Yambe; Shin-ichi Nitta
Journal:  Artif Organs       Date:  2003-01       Impact factor: 3.094

Review 6.  Mechanical circulatory support devices (MCSD) in Japan: current status and future directions.

Authors:  Setsuo Takatani; Hikaru Matsuda; Akihisa Hanatani; Chisato Nojiri; Kenji Yamazaki; Tadashi Motomura; Katsuhiro Ohuchi; Tohru Sakamoto; Takashi Yamane
Journal:  J Artif Organs       Date:  2005       Impact factor: 1.731

Review 7.  Third-generation blood pumps with mechanical noncontact magnetic bearings.

Authors:  Hideo Hoshi; Tadahiko Shinshi; Setsuo Takatani
Journal:  Artif Organs       Date:  2006-05       Impact factor: 3.094

8.  Improvement of hemocompatibility in centrifugal blood pump with hydrodynamic bearings and semi-open impeller: in vitro evaluation.

Authors:  Ryo Kosaka; Osamu Maruyama; Masahiro Nishida; Toru Yada; Sakae Saito; Shusaku Hirai; Takashi Yamane
Journal:  Artif Organs       Date:  2009-07-22       Impact factor: 3.094

9.  Use of motor current in flow rate measurement for the magnetically suspended centrifugal blood pump.

Authors:  T Tsukiya; T Akamatsu; K Nishimura; T Yamada; T Nakazeki
Journal:  Artif Organs       Date:  1997-05       Impact factor: 3.094

10.  Recent progress in the development of Terumo implantable left ventricular assist system.

Authors:  C Nojiri; T Kijima; J Maekawa; K Horiuchi; T Kido; T Sugiyama; T Mori; N Sugiura; T Asada; H Shimane; T Ozaki; M Suzuki; T Akamatsu; T Akutsu
Journal:  ASAIO J       Date:  1999 May-Jun       Impact factor: 2.872

View more
  1 in total

Review 1.  Journal of Artificial Organs 2011: the year in review.

Authors:  Y Sawa; E Tatsumi; A Funakubo; T Horiuchi; K Iwasaki; A Kishida; T Masuzawa; K Matsuda; A Myoui; M Nishimura; T Nishimura; S Tokunaga; Y Tomizawa; T Tomo; T Tsukiya; T Yamaoka
Journal:  J Artif Organs       Date:  2012-02-29       Impact factor: 1.731

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.