Literature DB >> 25407124

Passive magnetic bearing in the 3rd generation miniature axial flow pump-the valvo pump 2.

Eiji Okamoto1, Yuya Ishida, Tetsuya Yano, Yoshinori Mitamura.   

Abstract

The new miniature axial flow pump (valvo pump 2) that is installed at the base of the ascending aorta consists of a six-phase stator, an impeller in which four neodymium magnets are incorporated, and passive magnetic bearings that suspend the impeller for axial levitation. The impeller is sustained by hydrodynamic force between the blade tip of the impeller and the inner housing of the stator. The passive magnetic bearing consists of a ring neodymium magnet and a columnar neodymium magnet. The ring neodymium magnet is set in the stationary side and the columnar neodymium magnet is incorporated in the impeller shaft. Both neodymium magnets are coaxially mounted, and the anterior and posterior passive magnetic bearings suspend the impeller by repulsion force against the hydrodynamic force that acts to move the impeller in the inflow port direction. The passive magnetic bearing was evaluated by a tensile test, and the levitation force of 8.5 N and stiffness of 2.45 N/mm was obtained. Performance of the axial flow pump was evaluated by an in vitro experiment. The passive magnetic bearing showed sufficient levitation capacity to suspend the impeller in an axial direction. In conclusion, the passive magnetic bearing is promising to be one of levitation technology for the third-generation axial flow blood pump.

Mesh:

Year:  2014        PMID: 25407124     DOI: 10.1007/s10047-014-0806-9

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  11 in total

1.  Axial type self-bearing motor for axial flow blood pump.

Authors:  Yohji Okada; Toru Masuzawa; Ken-Ichi Matsuda; Kunihiro Ohmori; Takashi Yamane; Yoshiaki Konishi; Shinya Fukahori; Satoshi Ueno; Seung-Jong Kim
Journal:  Artif Organs       Date:  2003-10       Impact factor: 3.094

2.  A magnetic fluid seal for rotary blood pumps: effects of seal structure on long-term performance in liquid.

Authors:  Yoshinori Mitamura; Sayaka Takahashi; Shuichi Amari; Eiji Okamoto; Shun Murabayashi; Ikuya Nishimura
Journal:  J Artif Organs       Date:  2010-12-29       Impact factor: 1.731

3.  A novel permanent maglev rotary LVAD with passive magnetic bearings.

Authors:  K X Qian; H Y Yuan; P Zeng; W M Ru
Journal:  J Med Eng Technol       Date:  2005 Sep-Oct

4.  Use of aortic valvo-pumps placed in valve annulus for long-term left ventricular assist.

Authors:  Kun-Xi Qian; Dongfang Wang; Stephen R Topaz; Wei-Min Ru; Pei Zeng; Hai-Yu Yuan; Hao Wang; Fang-Qung Wang; Zi-Gang Feng; Joseph B Zwischenberger
Journal:  ASAIO J       Date:  2005 Nov-Dec       Impact factor: 2.872

Review 5.  Third-generation blood pumps with mechanical noncontact magnetic bearings.

Authors:  Hideo Hoshi; Tadahiko Shinshi; Setsuo Takatani
Journal:  Artif Organs       Date:  2006-05       Impact factor: 3.094

6.  The valvo-pump. An axial, nonpulsatile blood pump.

Authors:  Y Mitamura; R Yozu; T Tanaka; K Yamazaki
Journal:  ASAIO Trans       Date:  1991 Jul-Sep

7.  High efficiency magnetic bearing for a rotary blood pump.

Authors:  H M Chen; W A Smith; J F Walton
Journal:  ASAIO J       Date:  1998 Sep-Oct       Impact factor: 2.872

8.  Initial in vivo evaluation of the newly developed axial flow turbo pump with hydrodynamic bearings.

Authors:  Hideyuki Tanaka; Tomonori Tsukiya; Eisuke Tatsumi; Toshihide Mizuno; Tatsuya Hidaka; Takeshi Okubo; Toshiyuki Osada; Shinji Miyamoto; Yoshiyuki Taenaka
Journal:  J Artif Organs       Date:  2011-01-05       Impact factor: 1.731

9.  First clinical experience with the Incor left ventricular assist device.

Authors:  Christof Schmid; Tonny D T Tjan; Christian Etz; Christoph Schmidt; Frauke Wenzelburger; Markus Wilhelm; Markus Rothenburger; Gabi Drees; Hans H Scheld
Journal:  J Heart Lung Transplant       Date:  2005-09       Impact factor: 10.247

10.  Fifth INTERMACS annual report: risk factor analysis from more than 6,000 mechanical circulatory support patients.

Authors:  James K Kirklin; David C Naftel; Robert L Kormos; Lynne W Stevenson; Francis D Pagani; Marissa A Miller; J T Baldwin; J Timothy Baldwin; James B Young
Journal:  J Heart Lung Transplant       Date:  2013-02       Impact factor: 10.247

View more
  3 in total

Review 1.  Artificial hearts-recent progress: republication of the article published in the Japanese Journal of Artificial Organs.

Authors:  Masahiro Nishida
Journal:  J Artif Organs       Date:  2017-06-15       Impact factor: 1.731

2.  Measurement of hemodynamic changes with the axial flow blood pump installed in descending aorta.

Authors:  Eiji Okamoto; Tetsuya Yano; Hidekazu Miura; Yasuyuki Shiraishi; Tomoyuki Yambe; Yoshinori Mitamura
Journal:  J Artif Organs       Date:  2017-09-08       Impact factor: 1.731

3.  Development of a novel shrouded impeller pediatric blood pump.

Authors:  Talha Irfan Khan; Haris Sheh Zad; Ismail Lazoglu; Ozlem Yalcin
Journal:  J Artif Organs       Date:  2018-02-24       Impact factor: 1.731

  3 in total