Literature DB >> 16681061

Assessment of the anterior structures of eyes in a normal Northern Thai group using the Orbscan II.

Napaporn Tananuvat1, Nalinee Pansatiankul.   

Abstract

OBJECTIVES: To evaluate the anterior structures of the eyes in normal Northern Thais include the corneal topography and thickness, as well as the anterior chamber depth (ACD) and the white-to-white (WTW) using the Orbscan II system. MATERIAL AND
METHOD: One hundred and six eyes of 56 normal subjects were investigated using the Orbscan II. The simulated keratometry (SimK), astigmatism, corneal thickness, ACD and WTW were collected. The axial power maps as well as anterior and posterior elevation maps were read and categorized. Corneal thickness was measured in different regions and the pachymetry patterns were classified.
RESULTS: The mean SimK was 44.18 (1.41)/43.30 (1.46) diopters (D) and the mean astigmatism was 0.93 (0.58) D. Symmetric bow tie was the most common axial power pattern in the anterior cornea (57.6%), followed by asymmetric bow tie (19.8%), irregular patterns (12.3%), round (9.4%), and oval (0.9%). Incomplete ridge (40.6%) and island (34%) were common elevation patterns observed in the anterior corneal surface, and island (92.5%) was the most common topographic pattern in the posterior. The thinnest point on the cornea had an average thickness of 512.49 (35) micron and was located at an average of 0.43 (0.24) mm from visual axis. In the pachymetry maps, round (47.2%) and oval (45.3%) were common patterns. The mean ACD and WTW was 2.79 (0.35) and 11.61 (0.36) mm, respectively.
CONCLUSION: The present study demonstrated the normal variations of anterior segment structures of the eyes in normal Northern Thais using the Orbscan II topography system. This information may be useful for comparison with further quantitative studies of various abnormal states.

Entities:  

Mesh:

Year:  2005        PMID: 16681061

Source DB:  PubMed          Journal:  J Med Assoc Thai        ISSN: 0125-2208


  7 in total

1.  White-to-white corneal diameter: normal values in healthy Iranian population obtained with the Orbscan II.

Authors:  Hamid Gharaee; Mojtaba Abrishami; Masoud Shafiee; Asieh Ehsaei
Journal:  Int J Ophthalmol       Date:  2014-04-18       Impact factor: 1.779

2.  Corneal elevation topography: best fit sphere, elevation distance, asphericity, toricity, and clinical implications.

Authors:  Damien Gatinel; Jacques Malet; Thanh Hoang-Xuan; Dimitri T Azar
Journal:  Cornea       Date:  2011-05       Impact factor: 2.651

3.  Determining vertical fusion values from digital photographs of healthy eyes.

Authors:  Supaporn Tengtrisorn; Mayuree Montriwet; Kornkamon Sertsom
Journal:  Int Ophthalmol       Date:  2022-07-07       Impact factor: 2.031

4.  Day to Day Clinically Relevant Corneal Elevation, Thickness, and Curvature Parameters Using the Orbscan II Scanning Slit Topographer and the Pentacam Scheimpflug Imaging Device.

Authors:  Hassan Hashemi; Shiva Mehravaran
Journal:  Middle East Afr J Ophthalmol       Date:  2010-01

5.  The prevalence of astigmatism and its determinants in a rural population of Iran: the "Nooravaran Salamat" mobile eye clinic experience.

Authors:  Hassan Hashemi; Farhad Rezvan; Abbas Ali Yekta; Maryam Hashemi; Reza Norouzirad; Mehdi Khabazkhoob
Journal:  Middle East Afr J Ophthalmol       Date:  2014 Apr-Jun

6.  The distribution of orbscan indices in young population.

Authors:  Hassan Hashemi; Mehdi Khabazkhoob; Negareh Yazdani; Hadi Ostadimoghaddam; Payam Nabovati; Raheleh Moravej; AbbasAli Yekta
Journal:  J Curr Ophthalmol       Date:  2016-08-31

7.  Corneal topography patterns in the Tehran eye study: warning about the high prevalence of patterns with a skewed radial axis.

Authors:  Hassan Hashemi; Asghar Beiranvand; Mehdi Khabazkhoob; Akbar Fotouhi
Journal:  Middle East Afr J Ophthalmol       Date:  2014 Jan-Mar
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.