Literature DB >> 35796908

Determining vertical fusion values from digital photographs of healthy eyes.

Supaporn Tengtrisorn1, Mayuree Montriwet2, Kornkamon Sertsom3,4.   

Abstract

PURPOSE: To determine the mean difference of vertical corneal light reflex (VCLR) among healthy eyes via digital photography. STUDY
DESIGN: Retrospective study.
METHODS: The study enrolled 155, healthy eyes participants, 71 males and 84 females with a mean age of 14.7 years (range 12-19 years). The participants received complete eye examinations and 2 digital photographs were taken, with the flash on, while participants fixated their eyes on a near and a distant target. Two hundred and eighty qualified photographs were analyzed by Photo-Hirschberg testing using computer software. The vertical corneal light reflex ratio (VCLRR) was calculated as the distance of the corneal light reflex (CLR) to the inferior limbus or to the pupillary border divided by the horizontal corneal diameter, defined as VCLRR1 or VCLRR2. VCLRR was analyzed using Spearman's correlation.
RESULTS: The mean ± SD of horizontal corneal diameter in near and distance photographs was 11.47 ± 0.62 and 11.37 ± 0.58 mm, respectively. For correlation analysis, at 1 m fixation and 6 m fixation, the number of participants within an acceptable range of vertical fusion were 94.6% and 100% of participants. The 95th percentiles (estimated as the mean ± 1.64SD) in VCLRR1 between the two eyes at near and at distance fixation were 0.0316 and 0.0272, respectively; whereas the corresponding values for VCLRR2 were 0.0309 and 0.0240, respectively.
CONCLUSIONS: The normal range of the vertical corneal light reflex ratio suggests that the Photo-Hirschberg test could be used for screening vertical strabismus cases depending on iris pigment.
© 2022. The Author(s), under exclusive licence to Springer Nature B.V.

Entities:  

Keywords:  Photo-Hirschberg test; Photograph; Vertical fusion; Vertical strabismus

Year:  2022        PMID: 35796908     DOI: 10.1007/s10792-022-02405-3

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  11 in total

1.  Vertical fusion amplitude in normal adults.

Authors:  K Sharma; A S Abdul-Rahim
Journal:  Am J Ophthalmol       Date:  1992-11-15       Impact factor: 5.258

2.  Assessment of the anterior structures of eyes in a normal Northern Thai group using the Orbscan II.

Authors:  Napaporn Tananuvat; Nalinee Pansatiankul
Journal:  J Med Assoc Thai       Date:  2005-11

3.  The normal range of central corneal light reflex ratio in Thai children.

Authors:  Supaporn Tengtrisorn
Journal:  J Med Assoc Thai       Date:  2012-03

4.  The central corneal light reflex ratio from photographs derived from a digital camera in young adults.

Authors:  Suampa Duangsang; Supaporn Tengtrisorn
Journal:  J Med Assoc Thai       Date:  2012-05

5.  The Calibration of the Corneal Light Reflex to Estimate the Degree of an Angle of Deviation.

Authors:  Supaporn Tengtrisorn; Sitthi Tangkijwongpaisarn; Somporn Burachokvivat
Journal:  J Med Assoc Thai       Date:  2015-12

6.  Photographic calibration of the Hirschberg test.

Authors:  S E Brodie
Journal:  Invest Ophthalmol Vis Sci       Date:  1987-04       Impact factor: 4.799

7.  Individual case photogrammetric calibration of the Hirschberg Ratio (HR) for corneal light reflection test strabometry.

Authors:  Paul E Romano
Journal:  Binocul Vis Strabismus Q       Date:  2006

8.  Videographic Hirschberg measurement of simulated strabismic deviations.

Authors:  J M Miller; M Mellinger; J Greivenkemp; K Simons
Journal:  Invest Ophthalmol Vis Sci       Date:  1993-10       Impact factor: 4.799

9.  Cost effectiveness analysis of a visual screening program for primary school children in Thailand.

Authors:  Supaporn Tengtrisorn; Pasuree Sangsupawanitch; Wannee Chansawang
Journal:  J Med Assoc Thai       Date:  2009-08

10.  Calibration of the Hirschberg test in human infants.

Authors:  P M Riddell; L Hainline; I Abramov
Journal:  Invest Ophthalmol Vis Sci       Date:  1994-02       Impact factor: 4.799

View more