Literature DB >> 16670475

The effects of eye drops on corneal thickness in adult myopia.

Lei Gao1, Huijun Fan, Arthur C K Cheng, Zhonghao Wang, Dennis S C Lam.   

Abstract

PURPOSE: To study the effects of Complex Tropicamide (0.5% Tropicamide and 0.5% phenylephrine HCI) and Saline solution on corneal thickness in adult myopic patients with the Orbscan II system.
SETTING: Department of Ophthalmology, Yantai Yuhuangding Hospital.
DESIGN: Prospective, nonrandomized, clinical trial.
METHODS: The thinnest pachymetry of the cornea was obtained before and 1.5 hours after administration of three drops of Complex Tropicamide to the left eyes of 58 patients (58 eyes) and Saline solution to their 31 right eyes, respectively. The corneal thickness of the other 27 right eyes before and 1.5 hours after eyelid closure without exposure to eye drops was used as the control group.
RESULTS: The thinnest pachymetry of the cornea was significantly higher after exposure to eye drops in the Tropicamide group (23.36 +/- 15.01 microm; t = -11.855, P < 0.001). Similar findings were also noted in the Saline group (7.13 +/- 8.11 microm, t = -4.894, P < 0.001). The difference between the two groups was also significant (t = 6.737, P < 0.001). There were no statistically changes in corneal thickness in control group. The drops tested have no effect on the location of the thinnest corneal site and its distance form the visual axis.
CONCLUSION: Eye drops including Saline solutions may have significant effects on the corneal thickness in myopia, and this may have implications for corneal refractive surgery.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16670475     DOI: 10.1097/01.ico.0000214205.29823.f6

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  9 in total

1.  Comparison of central corneal thickness measurements with three new optical devices and a standard ultrasonic pachymeter.

Authors:  Hasan Ali Bayhan; Seray Aslan Bayhan; Izzet Can
Journal:  Int J Ophthalmol       Date:  2014-04-18       Impact factor: 1.779

2.  A new, specular reflection-based, precorneal tear film stability measurement technique in a rabbit model: viscoelastic increases tear film stability.

Authors:  Derek Nankivil; Alex Gonzalez; Esdras Arrieta; Cornelis Rowaan; Mariela C Aguilar; Krystal Sotolongo; Florence A Cabot; Sonia H Yoo; Jean-Marie A Parel
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-06-19       Impact factor: 4.799

3.  Central corneal thickness, intraocular pressure, and degree of myopia in an adult myopic population aged 20 to 40 years in southeast Spain: determination and relationships.

Authors:  Manuel Garcia-Medina; Jose Javier Garcia-Medina; Pablo Garrido-Fernandez; Jose Galvan-Espinosa; Jesus Martin-Molina; Carlos Garcia-Maturana; Sergio Perez-Pardo; Maria Dolores Pinazo-Duran
Journal:  Clin Ophthalmol       Date:  2011-02-28

4.  Anterior Segment Biometry with Phenylephrine and Tropicamide during Accommodation Imaged with Ultralong Scan Depth Optical Coherence Tomography.

Authors:  Junna Zhang; Yang Ni; Peng Li; Wen Sun; Mengyun Liu; Dongyu Guo; Chixin Du
Journal:  J Ophthalmol       Date:  2019-02-25       Impact factor: 1.909

5.  Sirius Scheimpflug-Placido versus ultrasound pachymetry for central corneal thickness: meta-analysis.

Authors:  Yili Jin; Colm McAlinden; Yong Sun; Daizong Wen; Yiran Wang; Jinjin Yu; Ke Feng; Benhao Song; Qinmei Wang; Shihao Chen; Jinhai Huang
Journal:  Eye Vis (Lond)       Date:  2021-02-18

6.  Comparison of central corneal thickness measurements with three different optical devices.

Authors:  Mehmet Barış Üçer; Erdinç Bozkurt
Journal:  Ther Adv Ophthalmol       Date:  2021-02-23

7.  Effect of Mydriasis-Caused Intraocular Pressure Changes on Corneal Biomechanical Metrics.

Authors:  Yufeng Ye; Yi Li; Zehui Zhu; Anas Ziad Masoud Abu Said; Kevin Nguelemo Mayopa; Stephen Akiti; Chengyi Huang; Bernardo T Lopes; Ashkan Eliasy; Yuanyuan Miao; Junjie Wang; Xiaobo Zheng; Shihao Chen; Fangjun Bao; Ahmed Elsheikh
Journal:  Front Bioeng Biotechnol       Date:  2021-11-26

8.  Intraobserver Repeatability of Corneal and Anterior Segment Parameters Obtained Using a Scheimpflug Camera-Placido Corneal Topography System.

Authors:  Elif Ertan; Mustafa Dogan
Journal:  Beyoglu Eye J       Date:  2019-08-06

9.  Effect of Cycloplegia on Corneal Biometrics and Refractive State.

Authors:  Abbas Bagheri; Mohadeseh Feizi; Aliakbar Shafii; Amir Faramarzi; Mehdi Tavakoli; Shahin Yazdani
Journal:  J Ophthalmic Vis Res       Date:  2018 Apr-Jun
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.