Literature DB >> 16632618

Occupational radiation doses in interventional cardiology: a 15-year follow-up.

E Vaño1, L Gonzalez, J M Fernandez, F Alfonso, C Macaya.   

Abstract

This report describes occupational radiation doses of interventional cardiologists over 15 years and assesses action undertaken to optimize radiation protection. Personal dosimetry records of nine staff cardiologists and eight interventional cardiology fellows were recorded using personal dosemeters worn over and under their lead aprons. The hospital in which this study was conducted currently performs 5000 cardiology procedures per year. The hospital has improved its facilities since 1989, when it had two old-fashioned theatres, to include four rooms with more advanced and safer equipment. Intensive radiation protection training was also implemented since 1989. Initially, some individual dose values in the range of 100-300 mSv month(-1), which risked exceeding some regulatory dose limits, were measured over the lead apron. Several doses in the range of 5-11 mSv month(-1) were recorded under the apron (mean = 10.2 mSv year(-1)). During the last 5 years of the study, after the implementation of the radiation protection actions and a programme of patient-dose optimization, the mean dose under the apron was reduced to 1.2 mSv year(-1). Current mean occupational doses recorded under the lead apron are 14% of those recorded during 1989-1992 and those recorded over the apron are 14-fold less than those recorded during 1989-1992. The regulatory dose limits and the threshold for lens injuries might have been exceeded if radiation protection facilities had not been used systematically. The most effective actions involved in reducing the radiation risk were training in radiation protection, a programme of patient-dose reduction and the systematic use of radiation protection facilities, specifically ceiling-suspended protective screens.

Entities:  

Mesh:

Year:  2006        PMID: 16632618     DOI: 10.1259/bjr/26829723

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  33 in total

Review 1.  Personal dosimetry for interventional operators: when and how should monitoring be done?

Authors:  C J Martin
Journal:  Br J Radiol       Date:  2010-12-15       Impact factor: 3.039

2.  Dose measurement on both patients and operators during neurointerventional procedures using photoluminescence glass dosimeters.

Authors:  T Moritake; Y Matsumaru; T Takigawa; K Nishizawa; A Matsumura; K Tsuboi
Journal:  AJNR Am J Neuroradiol       Date:  2008-08-21       Impact factor: 3.825

3.  Mobile C-arm cone-beam CT for guidance of spine surgery: image quality, radiation dose, and integration with interventional guidance.

Authors:  S Schafer; S Nithiananthan; D J Mirota; A Uneri; J W Stayman; W Zbijewski; C Schmidgunst; G Kleinszig; A J Khanna; J H Siewerdsena
Journal:  Med Phys       Date:  2011-08       Impact factor: 4.071

4.  Maternal occupational exposure to ionizing radiation and major structural birth defects.

Authors:  Hyeyeun Lim; A J Agopian; Lawrence W Whitehead; Charles W Beasley; Peter H Langlois; Robert J Emery; Dorothy Kim Waller
Journal:  Birth Defects Res A Clin Mol Teratol       Date:  2015-03-28

Review 5.  [Radiation protection in interventional radiology].

Authors:  R Adamus; R Loose; M Wucherer; M Uder; M Galster
Journal:  Radiologe       Date:  2016-03       Impact factor: 0.635

6.  Towards Robot-Assisted Echocardiographic Monitoring in Catheterization Laboratories : Usability-Centered Manipulator for Transesophageal Echocardiography.

Authors:  Christina Pahl; Henning Ebelt; Mostafa Sayahkarajy; Eko Supriyanto; Amiliana Soesanto
Journal:  J Med Syst       Date:  2017-08-15       Impact factor: 4.460

7.  Changing Patterns in the Performance of Fluoroscopically Guided Interventional Procedures and Adherence to Radiation Safety Practices in a U.S. Cohort of Radiologic Technologists.

Authors:  Hyeyeun Lim; Martha S Linet; Miriam E Van Dyke; Donald L Miller; Steven L Simon; Alice J Sigurdson; Cari M Kitahara
Journal:  AJR Am J Roentgenol       Date:  2016-08-30       Impact factor: 3.959

8.  Staff radiation doses in interventional cardiology: correlation with patient exposure.

Authors:  Eliseo Vano; Carlos Ubeda; Fernando Leyton; Patricia Miranda; Luciano Gonzalez
Journal:  Pediatr Cardiol       Date:  2009-01-29       Impact factor: 1.655

9.  Influence of surgeon's experience on fluoroscopy time during endourological interventions.

Authors:  M Ritter; F Siegel; P Krombach; A Martinschek; C Weiss; A Häcker; A E Pelzer
Journal:  World J Urol       Date:  2012-08-12       Impact factor: 4.226

Review 10.  Health risk and biological effects of cardiac ionising imaging: from epidemiology to genes.

Authors:  Ilenia Foffa; Monica Cresci; Maria Grazia Andreassi
Journal:  Int J Environ Res Public Health       Date:  2009-06-19       Impact factor: 3.390