Literature DB >> 16631254

Anterior chamber depth measurement before and after photorefractive keratectomy: comparison between IOL master and Orbscan II.

Nicola Rosa1, Michele Lanza, Luigi Capasso, Marcella Lucci, Biagio Polito, Antonio Romano.   

Abstract

PURPOSE: To measure the anterior chamber depth (ACD) with 2 different devices before and after photorefractive keratectomy (PRK).
DESIGN: Noncomparative case series. PARTICIPANTS: One hundred forty-three eyes of 143 patients who had undergone PRK with refractive errors ranging from -13.13 diopters (D) to +7 D (mean, -3.67+/-3.58) were analyzed.
METHODS: The ACD values preoperatively and at 1, 3, and 6 months postoperatively were measured with the Orbscan II and IOL Master. The results were analyzed using the Pearson correlation. MAIN OUTCOME MEASURE: Anterior chamber depth.
RESULTS: The instruments showed good agreement between the measurements before and after surgery. A significant decrease between the preoperative and 1-month postoperative measurements was found in the ACD measured from the epithelium with Orbscan II (P<0.01) and IOL Master (P<0.01). A nonsignificant decrease with both IOL Master (P>0.01) and Orbscan II (P>0.01) was found between 3 and 6 months after surgery. The ACD measured from the endothelium using the Orbscan II showed a significant difference only between the 3- and 6-month follow-up data (P<0.01).
CONCLUSIONS: The 2 devices showed good agreement, and the changes detected postoperatively seem to be related not only to corneal thinning but also to anterior segment remodeling.

Entities:  

Mesh:

Year:  2006        PMID: 16631254     DOI: 10.1016/j.ophtha.2006.02.022

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  7 in total

Review 1.  Device interchangeability on anterior chamber depth and white-to-white measurements: a thorough literature review.

Authors:  Alberto Domínguez-Vicent; Cari Pérez-Vives; Teresa Ferrer-Blasco; Santiago García-Lázaro; Robert Montés-Micó
Journal:  Int J Ophthalmol       Date:  2016-07-18       Impact factor: 1.779

2.  Long-term results of corneal collagen crosslinking for progressive keratoconus.

Authors:  Maddalena De Bernardo; Luigi Capasso; Michele Lanza; Antonia Tortori; Stefania Iaccarino; Michela Cennamo; Maria Borrelli; Nicola Rosa
Journal:  J Optom       Date:  2014-06-16

3.  Agreement between Orbscan II, VuMAX UBM and Artemis-2 very-high frequency ultrasound scanner for measurement of anterior chamber depth.

Authors:  Haya Matuoq Al Farhan
Journal:  BMC Ophthalmol       Date:  2014-02-25       Impact factor: 2.209

4.  Comparison of anterior segment measurements obtained by three different devices in healthy eyes.

Authors:  Carmen Lopez de la Fuente; Ana Sanchez-Cano; Francisco Segura; Isabel Pinilla
Journal:  Biomed Res Int       Date:  2014-06-02       Impact factor: 3.411

Review 5.  IOL power calculation after corneal refractive surgery.

Authors:  Maddalena De Bernardo; Luigi Capasso; Luisa Caliendo; Francesco Paolercio; Nicola Rosa
Journal:  Biomed Res Int       Date:  2014-07-21       Impact factor: 3.411

6.  Accuracy of Different Topographic Instruments in Calculating Corneal Power after Myopic Photorefractive Keratectomy.

Authors:  Alireza Baradaran-Rafii; Sahba Fekri; Mohammad Rezaie; Shahram Salehi-Rad; Ali Moradi; Tahmineh Motevasseli; Masumeh Kalantarion
Journal:  J Ophthalmic Vis Res       Date:  2017 Jul-Sep

7.  Comparison of anterior segment changes after femtosecond laser LASIK and SMILE using a dual rotating Scheimpflug analyzer.

Authors:  Bu Ki Kim; Su Joung Mun; Young Hoon Yang; Ji Sun Kim; Jun Hyung Moon; Young Taek Chung
Journal:  BMC Ophthalmol       Date:  2019-12-11       Impact factor: 2.209

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.