Literature DB >> 16613932

Radiofrequency ablation of arrhythmias guided by non-fluoroscopic catheter location: a prospective randomized trial.

Mark J Earley1, Refai Showkathali, Maysaa Alzetani, Peter M Kistler, Dhiraj Gupta, Dominic J Abrams, Julie A Horrocks, Stuart J Harris, Simon C Sporton, Richard J Schilling.   

Abstract

AIMS: To compare the utility of non-fluoroscopic mapping systems (Carto and Ensite NavX) with that of conventional mapping in patients referred for catheter ablation of a wide variety of arrhythmias. METHODS AND
RESULTS: Patients referred for catheter ablation (excluding atrial fibrillation, atypical atrial flutter, ventricular tachycardia in structural heart disease, and complete AV nodal ablation) were randomized equally to a procedure guided by Carto, Ensite NavX, or conventional mapping. A total of 145 patients were recruited (82 men, aged 49+/-16, range 18-85). In 19 patients, no ablation was performed, and in the remaining, typical atrial flutter, atrioventricular nodal re-entrant tachycardia, and atrioventricular re-entrant tachycardias [including Wolff-Parkinson-White (WPW)] accounted for 93% of ablations. Overall procedure time, immediate and short-term success, complication rate, and freedom from symptoms at follow-up were identical for all groups. NavX led to the least X-ray exposure: Navx vs. conventional, median (range): 4 (0-50) vs. 13 (2-46) min (P<0.001); NavX vs. Carto, median (range): 4 (0-50) vs. 6 (1-55) min (P=0.008). Both Carto and NavX increased disposable costs by 50% when compared with conventional (P<0.001). For typical atrial flutter, Carto and NavX reduced screening times without increasing procedure cost. If ablation was not performed, NavX was twice as expensive as Carto or conventional.
CONCLUSION: Ensite NavX and Carto procedures have similar effectiveness and safety to a conventional approach; however, they both reduce X-ray exposure, with NavX producing a significantly greater effect than Carto. Although this benefit is achieved at a greater financial cost, there may be long-term benefits to catheter laboratory staff.

Entities:  

Mesh:

Year:  2006        PMID: 16613932     DOI: 10.1093/eurheartj/ehi834

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  51 in total

1.  First in vivo use of a capacitive micromachined ultrasound transducer array-based imaging and ablation catheter.

Authors:  Douglas N Stephens; Uyen T Truong; Amin Nikoozadeh; Omer Oralkan; Chi Hyung Seo; Jonathan Cannata; Aaron Dentinger; Kai Thomenius; Alan de la Rama; Tho Nguyen; Feng Lin; Pierre Khuri-Yakub; Aman Mahajan; Kalyanam Shivkumar; Matt O'Donnell; David J Sahn
Journal:  J Ultrasound Med       Date:  2012-02       Impact factor: 2.153

2.  2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias.

Authors:  Edmond M Cronin; Frank M Bogun; Philippe Maury; Petr Peichl; Minglong Chen; Narayanan Namboodiri; Luis Aguinaga; Luiz Roberto Leite; Sana M Al-Khatib; Elad Anter; Antonio Berruezo; David J Callans; Mina K Chung; Phillip Cuculich; Andre d'Avila; Barbara J Deal; Paolo Della Bella; Thomas Deneke; Timm-Michael Dickfeld; Claudio Hadid; Haris M Haqqani; G Neal Kay; Rakesh Latchamsetty; Francis Marchlinski; John M Miller; Akihiko Nogami; Akash R Patel; Rajeev Kumar Pathak; Luis C Saenz Morales; Pasquale Santangeli; John L Sapp; Andrea Sarkozy; Kyoko Soejima; William G Stevenson; Usha B Tedrow; Wendy S Tzou; Niraj Varma; Katja Zeppenfeld
Journal:  J Interv Card Electrophysiol       Date:  2020-10       Impact factor: 1.900

3.  2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation.

Authors:  Hugh Calkins; Gerhard Hindricks; Riccardo Cappato; Young-Hoon Kim; Eduardo B Saad; Luis Aguinaga; Joseph G Akar; Vinay Badhwar; Josep Brugada; John Camm; Peng-Sheng Chen; Shih-Ann Chen; Mina K Chung; Jens Cosedis Nielsen; Anne B Curtis; D Wyn Davies; John D Day; André d'Avila; N M S Natasja de Groot; Luigi Di Biase; Mattias Duytschaever; James R Edgerton; Kenneth A Ellenbogen; Patrick T Ellinor; Sabine Ernst; Guilherme Fenelon; Edward P Gerstenfeld; David E Haines; Michel Haissaguerre; Robert H Helm; Elaine Hylek; Warren M Jackman; Jose Jalife; Jonathan M Kalman; Josef Kautzner; Hans Kottkamp; Karl Heinz Kuck; Koichiro Kumagai; Richard Lee; Thorsten Lewalter; Bruce D Lindsay; Laurent Macle; Moussa Mansour; Francis E Marchlinski; Gregory F Michaud; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Ken Okumura; Douglas Packer; Evgeny Pokushalov; Matthew R Reynolds; Prashanthan Sanders; Mauricio Scanavacca; Richard Schilling; Claudio Tondo; Hsuan-Ming Tsao; Atul Verma; David J Wilber; Teiichi Yamane
Journal:  Heart Rhythm       Date:  2017-05-12       Impact factor: 6.343

Review 4.  Arrhythmia Mechanisms Revealed by Ripple Mapping.

Authors:  George Katritsis; Vishal Luther; Prapa Kanagaratnam; Nick Wf Linton
Journal:  Arrhythm Electrophysiol Rev       Date:  2018-12

5.  Fluoroscopy-free AF ablation using transesophageal echocardiography and electroanatomical mapping technology.

Authors:  Benjamin O'Brien; Damian C Balmforth; Ross J Hunter; Richard J Schilling
Journal:  J Interv Card Electrophysiol       Date:  2017-11-14       Impact factor: 1.900

6.  2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design: a report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation. Developed in partnership with the European Heart Rhythm Association (EHRA), a registered branch of the European Society of Cardiology (ESC) and the European Cardiac Arrhythmia Society (ECAS); and in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), the Asia Pacific Heart Rhythm Society (APHRS), and the Society of Thoracic Surgeons (STS). Endorsed by the governing bodies of the American College of Cardiology Foundation, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, the Asia Pacific Heart Rhythm Society, and the Heart Rhythm Society.

Authors:  Hugh Calkins; Karl Heinz Kuck; Riccardo Cappato; Josep Brugada; A John Camm; Shih-Ann Chen; Harry J G Crijns; Ralph J Damiano; D Wyn Davies; John DiMarco; James Edgerton; Kenneth Ellenbogen; Michael D Ezekowitz; David E Haines; Michel Haissaguerre; Gerhard Hindricks; Yoshito Iesaka; Warren Jackman; José Jalife; Pierre Jais; Jonathan Kalman; David Keane; Young-Hoon Kim; Paulus Kirchhof; George Klein; Hans Kottkamp; Koichiro Kumagai; Bruce D Lindsay; Moussa Mansour; Francis E Marchlinski; Patrick M McCarthy; J Lluis Mont; Fred Morady; Koonlawee Nademanee; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Douglas L Packer; Carlo Pappone; Eric Prystowsky; Antonio Raviele; Vivek Reddy; Jeremy N Ruskin; Richard J Shemin; Hsuan-Ming Tsao; David Wilber
Journal:  Heart Rhythm       Date:  2012-03-01       Impact factor: 6.343

7.  A Cost-Effective Analysis of Systematically Using Mapping Systems During Catheter Ablation Procedures in Children and Teenagers.

Authors:  Massimiliano Marini; Daniele Ravanelli; Fabrizio Guarracini; Maurizio Del Greco; Silvia Quintarelli; Anna Cima; Alessio Coser; Marta Martin; Aldo Valentini; Roberto Bonmassari
Journal:  Pediatr Cardiol       Date:  2018-06-12       Impact factor: 1.655

8.  A family of intracardiac ultrasound imaging devices designed for guidance of electrophysiology ablation procedures.

Authors:  David J Sahn; Douglas N Stephens; Jonathan M Cannata; K Shung; Omer Oralkan; Amin Nikoozadeh; B T Pierre Khuri-Yakub; Hien Nguyen; Peter Chen; Aaron M Dentinger; Douglas Wildes; Kai E Thomenius; Aman Mahajan; Kalyanam Shivkumar; Matthew O'Donnell
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

9.  Multifunctional catheters combining intracardiac ultrasound imaging and electrophysiology sensing.

Authors:  D N Stephens; J Cannata; Ruibin Liu; Jian Zhong Zhao; K K Shung; Hien Nguyen; R Chia; A Dentinger; D Wildes; K E Thomenius; A Mahajan; K Shivkumar; Kang Kim; M O'Donnell; A Nikoozadeh; O Oralkan; P T Khuri-Yakub; D J Sahn
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-07       Impact factor: 2.725

10.  Reduction of radiation exposure in catheter ablation of atrial fibrillation: Lesson learned.

Authors:  Roberto De Ponti
Journal:  World J Cardiol       Date:  2015-08-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.