Literature DB >> 16606871

Effect of central corneal thickness, corneal curvature, and axial length on applanation tonometry.

Markus Kohlhaas1, Andreas G Boehm, Eberhard Spoerl, Antje Pürsten, Hans J Grein, Lutz E Pillunat.   

Abstract

OBJECTIVE: To evaluate the effect of central corneal thickness (CCT), corneal curvature, and axial length on applanation tonometry in an in vivo study.
METHODS: In a masked, prospective clinical trial, we examined 125 eyes of 125 patients scheduled for cataract surgery. Corneal curvature was measured by means of keratometry and axial length by A-scan ultrasonography. By cannulating the anterior chamber before surgery, intraocular pressure (IOP) was set to 20, 35, and 50 mm Hg in a closed system by means of a water column. After measuring thickness, the IOP was measured with an applanation tonometer. Pearson product moment correlations and multiple linear regression analyses were performed, and significance levels were evaluated by the paired, 2-tailed t test.
RESULTS: The difference between measured and real IOP was significantly dependent (P < .001) on CCT. The associations between IOP and corneal curvature or IOP and axial length were not statistically significant (P = .31). The association between IOP reading and CCT is shown in the "Dresdner correction table," which illustrates an approximately 1-mm Hg correction for every 25-microm deviation from a CCT of 550 microm. The correction values were positive as thickness decreased and negative as thickness increased.
CONCLUSIONS: Central corneal thickness significantly affects IOP readings obtained by applanation tonometry according to the Goldmann principle. A correction of IOP readings by considering CCT according to the Dresdner correction table might be helpful for determining an accurate IOP value.

Entities:  

Mesh:

Year:  2006        PMID: 16606871     DOI: 10.1001/archopht.124.4.471

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  83 in total

1.  Cornea plana associated with open-angle glaucoma: a case report.

Authors:  Bilge Ozturk Sahin; Goktug Seymenoglu; Esin F Baser
Journal:  Int Ophthalmol       Date:  2011-12-11       Impact factor: 2.031

2.  Transpalpebral measurement of intraocular pressure using the Diaton tonometer versus standard Goldmann applanation tonometry.

Authors:  Yuehua Li; Jingming Shi; Xuanchu Duan; Fang Fan
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-05-22       Impact factor: 3.117

3.  Comparison between Pascal dynamic contour tonometer and Goldmann applanation tonometer after different types of refractive surgery.

Authors:  Antonios P Aristeidou; Georgios Labiris; Andreas Katsanos; Michalis Fanariotis; Nikitas C Foudoulakis; Vassilios P Kozobolis
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-06-25       Impact factor: 3.117

4.  Non-penetrating intracanalicular partial trabeculectomy via the ostia of Schlemm's canal.

Authors:  Alexey V Dashevsky; Ines M Lanzl; Konstantin E Kotliar
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-09-23       Impact factor: 3.117

5.  Correlations between corneal and optic nerve head variables in healthy subjects and patients with primary open angle glaucoma.

Authors:  Federico Saenz-Frances; Luis Jañez; Lara Borrego-Sanz; Clara Berrozpe-Villabona; Jose Maria Martinez-de-la-Casa; Laura Morales-Fernandez; Julian Garcia-Sanchez; Enrique Santos-Bueso; Julian Garcia-Feijoo
Journal:  Int J Ophthalmol       Date:  2015-12-18       Impact factor: 1.779

6.  Central corneal thickness and correlation to optic disc size: a potential link for susceptibility to glaucoma.

Authors:  M Pakravan; A Parsa; M Sanagou; C F Parsa
Journal:  Br J Ophthalmol       Date:  2006-09-14       Impact factor: 4.638

7.  Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer over a wide IOP range.

Authors:  S Munkwitz; A Elkarmouty; E M Hoffmann; N Pfeiffer; H Thieme
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-01-12       Impact factor: 3.117

8.  [Influence of residual corneal bed thickness after myopic LASIK on intraocular pressure measurements. Goldmann applanation tonometry and dynamic contour tonometry].

Authors:  L Muller; T Kohnen
Journal:  Ophthalmologe       Date:  2009-01       Impact factor: 1.059

9.  Relationship of change in central corneal thickness to visual field progression in eyes with glaucoma.

Authors:  Deepa Viswanathan; Ivan Goldberg; Stuart L Graham
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-03-14       Impact factor: 3.117

10.  [Alterations in intraocular pressure and the CorVis parameters after LASIK].

Authors:  A Anton; M Neuburger; J F Jordan; T Wecker; J Lübke; S Heinzelmann; T Lapp; D Böhringer; T Reinhard; P Maier
Journal:  Ophthalmologe       Date:  2017-05       Impact factor: 1.059

View more