Hemodynamic monitoring over the past 10 years.

Michael R Pinsky1.   

Abstract

Changes in hemodynamic monitoring over the past 10 years have followed two paths. First, there has been a progressive decrease in invasive monitoring, most notably a reduction in the use of the pulmonary artery catheter because of a presumed lack of efficacy in its use in the management of critically ill patients, with an increased use of less invasive monitoring requiring only central venous and arterial catheterization to derive the same data. Second, numerous clinical trials have documented improved outcome and decreased costs when early goal-directed protocolized therapies are used in appropriate patient populations, such as patients with septic shock presenting to Emergency Departments and high-risk surgical patients before surgery (pre-optimization) and immediately after surgery (post-optimization). Novel monitoring will be driven more by its role in improving outcomes than in the technical abilities of the manufacturers.

Entities:  

Mesh:

Year:  2006        PMID: 16542473      PMCID: PMC1550811          DOI: 10.1186/cc3997

Source DB:  PubMed          Journal:  Crit Care        ISSN: 1364-8535            Impact factor:   9.097


Hemodynamic monitoring is a cornerstone in the care of the hemodynamically unstable patient. It serves as a monitor both of stability and acute deterioration and of response to therapy. Although hemodynamic monitoring is also both context specific and disease specific, it is primarily driven by technology and offset by utility. Nothing underscores this concept better than the decline in the use of the pulmonary artery catheter (PAC), whose use has markedly decreased while its ability to measure increasingly more hemodynamic variables increased [1]. In its ultimate format the PAC continuously measures temperature, heart rate, mixed venous saturation of O2 (SvO2), cardiac output, right ventricular ejection fraction and end-diastolic volume, central venous pressure and pulmonary arterial pressure. When coupled with non-invasive pulse oximetry, it can also give total body oxygen delivery (DO2) and consumption (VO2). Yet despite these impressive abilities, use of the PAC has decreased primarily because few, if any, clinical trials have shown that this litany of information improves management enough to alter patient outcome [2]. Clearly, the primary changes in hemodynamic monitoring over the past 10 years can be summarized as a decrease in use of the PAC with a greater use of measures, presumed to be less invasive, to derive the same hemodynamic data, and the institution of protocolized resuscitation approaches driven by selective hemodynamic measures. The initial logic for these trends is not clear because, until recently, patient outcomes have not been shown to be better when these data are available from the PAC, so why would outcomes improve if these same data are now available other means? Still, the major thrusts were in the realm of alternatives to the PAC, such as esophageal Doppler estimates of cardiac output [3] and arterial pressure pulse contour and signal processing estimates of stroke volume [4]. Furthermore, using only central venous and arterial access one can also measure central venous percentage saturation of hemoglobin with oxygen (SO2), cardiac output and other more esoteric parameters such as global cardiac volumes and lung water [5]. Although other technologies studied over the past 10 years focused on regional blood flow – examples are measures of splanchnic blood flow from a PAC inserted into a hepatic vein, gastric mucosal blood flow from gastric tonometry, and liver function by indocyanide green dye clearance – the generalized use of these monitoring techniques has never caught on, primarily because they were not associated with improved patient outcomes. Importantly, no monitoring device, no matter how accurate or complete, would be expected to improve patient outcome, unless coupled to a treatment that itself improves outcome [6]. This basic truth underscores the theme that has been increasingly commonly heard, namely that technology should not drive monitoring: improved outcomes-defined treatments should. Thus, several important clinical trials have documented that early aggressive resuscitation approached with guidance from defined hemodynamic variables using thoughtful protocols may improve outcome. Rivers et al. [7] showed that an aggressive resuscitation protocol guided by central venous SO2 and pulse oximetry (arterial oxygen saturation (SpO2)) and delivered in an Emergency Department improved outcome in patients with septic shock. This study was in contrast with the numerous earlier studies showing the futility of aggressive resuscitation once shock is established [8,9], or when PAC insertion is not associated with an aggressive resuscitation protocol [2,10]. The concept underscored by this newer trial was that appropriate resuscitation prevents subsequent tissue injury even if overt shock is present, if the resuscitation is performed early enough. The race was then on to identify other patient subsets whose outcomes could be improved by similar aggressive resuscitation approaches. Spurred on by the initial work of Shoemaker et al. [11], who showed that high-risk surgical patients could have their mortality decreased by a preemptive resuscitation protocol aimed at achieving a high initial DO2, referred to then as 'survivor levels of DO2'. Although this study was criticized for not having proper control groups, it did demonstrate that preventing initial ischemia may be useful. These findings were supported by Boyd et al. [12], who also demonstrated a survival advantage in preemptive resuscitation. This therapeutic philosophy has been referred to a 'pre-optimization' to distinguish itself from treatment of patients already in shock. Importantly, the recent literature has shown that pre-optimization protocols improve outcome [13] and are cost-effective [14]. Because pre-optimization approaches focus on maximizing DO2 before surgery in high-risk patients, hemodynamic measures of blood flow are all that are needed to accomplish these goals. Carrying this theme forward, recent studies have shown that in similar high-risk surgery patients, the use of aggressive fluid resuscitation in the immediate postoperative period also improves outcome, as measured by decreased length of stay and hospital costs [3,4]. Importantly, these 'post-optimization' approaches also rely on measuring only blood pressure, cardiac output, and SpO2, making them synchronous with the instrumentation needed for pre-optimization protocols. Finally, functional hemodynamic monitoring techniques, such as measuring variation in pulse pressure [15] or in stroke volume [16], have been shown to be robust markers of those subjects with a high propensity for increasing cardiac output if given a fluid challenge. Clinical trials using these parameters to document efficacy will need to be done, but will probably show that these measures also aid in defining appropriate therapy when resuscitation is planned. Thus, the future approaches to hemodynamic monitoring will, at the least, focus on measures of cardiac output, arterial pressure, and SvO2. To the extent that these measures can be made continuously and in a non-invasive fashion they will enjoy a wider degree of application and potentially prove cost-effective. Finally, these measures will be made more effective if coupled with parallel measurements of tissue wellness with other monitoring techniques. Although measures of sublingual tissue partial pressure of carbon dioxide (pCO2), sublingual capillary blood flow, tissue partial pressure of oxygen (pO2), pCO2, pH, and even NAD+/NADH ratios can be made [17], their utility in the diagnosis of critical illness and monitoring of response to therapy have yet to be proven. The linkage between these non-invasive continuous measures of metabolic function, global measures of hemodynamic status and clinical outcomes needs to be made and, if shown useful, may be the direction we take in the future to guide us in the resuscitation of patients with critical illness.

Abbreviations

DO2 = total body oxygen delivery; PAC = pulmonary artery catheter; pCO2 = tissue partial pressure of carbon dioxide; pO2 = tissue partial pressure of oxygen; SO2 = percentage saturation of hemoglobin with oxygen; SpO2 = arterial oxygen saturation; SvO2 = mixed venous saturation of O2.

Competing interests

MP is a medical advisor to Arrow International, Edwards Lifesciences and LiDCO Ltd. MP and the University of Pittsburgh co-own US patent no. 6,776,764, 'Use of aortic pressure pulse and flow in bedside hemodynamic management.'
  17 in total

1.  Early goal-directed therapy in the treatment of severe sepsis and septic shock.

Authors:  E Rivers; B Nguyen; S Havstad; J Ressler; A Muzzin; B Knoblich; E Peterson; M Tomlanovich
Journal:  N Engl J Med       Date:  2001-11-08       Impact factor: 91.245

2.  A trial of goal-oriented hemodynamic therapy in critically ill patients. SvO2 Collaborative Group.

Authors:  L Gattinoni; L Brazzi; P Pelosi; R Latini; G Tognoni; A Pesenti; R Fumagalli
Journal:  N Engl J Med       Date:  1995-10-19       Impact factor: 91.245

3.  Prospective trial of supranormal values of survivors as therapeutic goals in high-risk surgical patients.

Authors:  W C Shoemaker; P L Appel; H B Kram; K Waxman; T S Lee
Journal:  Chest       Date:  1988-12       Impact factor: 9.410

4.  Let us use the pulmonary artery catheter correctly and only when we need it.

Authors:  Michael R Pinsky; Jean-Louis Vincent
Journal:  Crit Care Med       Date:  2005-05       Impact factor: 7.598

5.  Pre-operative optimisation employing dopexamine or adrenaline for patients undergoing major elective surgery: a cost-effectiveness analysis.

Authors:  Elisabeth Fenwick; Jonathan Wilson; Mark Sculpher; Karl Claxton
Journal:  Intensive Care Med       Date:  2002-03-26       Impact factor: 17.440

6.  Randomised controlled trial assessing the impact of a nurse delivered, flow monitored protocol for optimisation of circulatory status after cardiac surgery.

Authors:  Moira McKendry; Helen McGloin; Debbie Saberi; Libby Caudwell; Anthony R Brady; Mervyn Singer
Journal:  BMJ       Date:  2004-07-08

7.  Relationship of pulmonary artery catheter use to mortality and resource utilization in patients with severe sepsis.

Authors:  D Tony Yu; Richard Platt; Paul N Lanken; Edgar Black; Kenneth E Sands; J Sanford Schwartz; Patricia L Hibberd; Paul S Graman; Katherine L Kahn; David R Snydman; Jeffrey Parsonnet; Richard Moore; David W Bates
Journal:  Crit Care Med       Date:  2003-12       Impact factor: 7.598

8.  Elevation of systemic oxygen delivery in the treatment of critically ill patients.

Authors:  M A Hayes; A C Timmins; E H Yau; M Palazzo; C J Hinds; D Watson
Journal:  N Engl J Med       Date:  1994-06-16       Impact factor: 91.245

9.  A randomized clinical trial of the effect of deliberate perioperative increase of oxygen delivery on mortality in high-risk surgical patients.

Authors:  O Boyd; R M Grounds; E D Bennett
Journal:  JAMA       Date:  1993-12-08       Impact factor: 56.272

10.  Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: a randomized controlled trial.

Authors:  Christian Richard; Josiane Warszawski; Nadia Anguel; Nicolas Deye; Alain Combes; Didier Barnoud; Thierry Boulain; Yannick Lefort; Muriel Fartoukh; Frederic Baud; Alexandre Boyer; Laurent Brochard; Jean-Louis Teboul
Journal:  JAMA       Date:  2003-11-26       Impact factor: 56.272

View more
  7 in total

Review 1.  Pulse pressure variation: where are we today?

Authors:  Maxime Cannesson; Mateo Aboy; Christoph K Hofer; Mohamed Rehman
Journal:  J Clin Monit Comput       Date:  2011-02       Impact factor: 2.502

2.  Use of insulin to decrease septic shock-induced myocardial depression in a porcine model.

Authors:  Yosef Levenbrown; Scott Penfil; Elena Rodriguez; Yan Zhu; Jobayer Hossain; A Majeed Bhat; Anne Hesek; Karen B O'Neil; Kelly Tobin; Thomas H Shaffer
Journal:  Inflammation       Date:  2013-12       Impact factor: 4.092

3.  Perioperative fluid guidance with transthoracic echocardiography and pulse-contour device in morbidly obese patients.

Authors:  Tomi Pösö; Ola Winsö; Roman Aroch; Doris Kesek
Journal:  Obes Surg       Date:  2014-12       Impact factor: 4.129

4.  Current practice in hemodynamic monitoring and management in high-risk surgery patients: a national survey of Korean anesthesiologists.

Authors:  Sang-Hyun Kim; Min-Jae Kim; Joon-Ho Lee; Sung-Hwan Cho; Won-Seok Chae; Maxime Cannesson
Journal:  Korean J Anesthesiol       Date:  2013-07-19

5.  Influence of different infracardial positions of central venous catheters in hemodynamic monitoring using the transpulmonal thermodilution method.

Authors:  Patrick Kellner; Viola Schleusener; Frank Bauerfeind; Jens Soukup
Journal:  J Clin Monit Comput       Date:  2015-09-04       Impact factor: 2.502

6.  Most Care®: a minimally invasive system for hemodynamic monitoring powered by the Pressure Recording Analytical Method (PRAM).

Authors:  S Romagnoli; S Bevilacqua; C Lazzeri; F Ciappi; D Dini; C Pratesi; G F Gensini; S M Romano
Journal:  HSR Proc Intensive Care Cardiovasc Anesth       Date:  2009

7.  Hemodynamic monitoring in Nigerian patients undergoing high-risk surgery.

Authors:  Babatunde Babasola Osinaike
Journal:  Indian J Crit Care Med       Date:  2015-07
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.