Literature DB >> 16532955

Development and evaluation of an exact fan-beam reconstruction algorithm using an equal weighting scheme via locally compensated filtered backprojection (LCFBP).

Guang-Hong Chen1, Ranjini Tokalkanahalli, Tingliang Zhuang, Brian E Nett, Jiang Hsieh.   

Abstract

A novel exact fan-beam image reconstruction formula is presented and validated using both phantom data and clinical data. This algorithm takes the form of the standard ramp filtered backprojection (FBP) algorithm plus local compensation terms. This algorithm will be referred to as a locally compensated filtered backprojection (LCFBP). An equal weighting scheme is utilized in this algorithm in order to properly account for redundantly measured projection data. The algorithm has the desirable property of maintaining a mathematically exact result for: the full scan mode (2pi), the short scan mode (pi+ full fan angle), and the supershort scan mode [less than (pi+ full fan angle)]. Another desirable feature of this algorithm is that it is derivative-free. This feature is beneficial in preserving the spatial resolution of the reconstructed images. The third feature is that an equal weighting scheme has been utilized in the algorithm, thus the new algorithm has better noise properties than the standard filtered backprojection image reconstruction with a smooth weighting function. Both phantom data and clinical data were utilized to validate the algorithm and demonstrate the superior noise properties of the new algorithm.

Entities:  

Mesh:

Year:  2006        PMID: 16532955     DOI: 10.1118/1.2165416

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Backprojection-filtration reconstruction without invoking a spatially varying weighting factor.

Authors:  Dan Xia; Seungryong Cho; Xiaochuan Pan
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

2.  Temporally targeted imaging method applied to ECG-gated computed tomography: preliminary phantom and in vivo experience.

Authors:  Brian E Nett; Shuai Leng; Joseph N Zambelli; Scott B Reeder; Michael A Speidel; Guang-Hong Chen
Journal:  Acad Radiol       Date:  2008-01       Impact factor: 3.173

3.  Image covariance and lesion detectability in direct fan-beam x-ray computed tomography.

Authors:  Adam Wunderlich; Frédéric Noo
Journal:  Phys Med Biol       Date:  2008-04-18       Impact factor: 3.609

4.  Simulation tools for two-dimensional experiments in x-ray computed tomography using the FORBILD head phantom.

Authors:  Zhicong Yu; Frédéric Noo; Frank Dennerlein; Adam Wunderlich; Günter Lauritsch; Joachim Hornegger
Journal:  Phys Med Biol       Date:  2012-06-20       Impact factor: 3.609

5.  Learning to Reconstruct Computed Tomography Images Directly From Sinogram Data Under A Variety of Data Acquisition Conditions.

Authors:  Yinsheng Li; Ke Li; Chengzhu Zhang; Juan Montoya; Guang-Hong Chen
Journal:  IEEE Trans Med Imaging       Date:  2019-04-11       Impact factor: 10.048

6.  A novel CT imaging system with adjacent double X-ray sources.

Authors:  Mou An; Yaoqin Xie
Journal:  Comput Math Methods Med       Date:  2013-11-14       Impact factor: 2.238

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.