Literature DB >> 16532944

Development of the two Korean adult tomographic computational phantoms for organ dosimetry.

Choonsik Lee1, Choonik Lee, Sang-Hyun Park, Jai-Ki Lee.   

Abstract

Following the previously developed Korean tomographic phantom, KORMAN, two additional whole-body tomographic phantoms of Korean adult males were developed from magnetic resonance (MR) and computed tomography (CT) images, respectively. Two healthy male volunteers, whose body dimensions were fairly representative of the average Korean adult male, were recruited and scanned for phantom development. Contiguous whole body MR images were obtained from one subject exclusive of the arms, while whole-body CT images were acquired from the second individual. A total of 29 organs and tissues and 19 skeletal sites were segmented via image manipulation techniques such as gray-level thresholding, region growing, and manual drawing, in which each of segmented image slice was subsequently reviewed by an experienced radiologist for anatomical accuracy. The resulting phantoms, the MR-based KTMAN-1 (Korean Typical MAN-1) and the CT-based KTMAN-2 (Korean Typical MAN-2), consist of 300 X 150 X 344 voxels with a voxel resolution of 2 X 2 X 5 mm3 for both phantoms. Masses of segmented organs and tissues were calculated as the product of a nominal reference density, the prevoxel volume, and the cumulative number of voxels defining each organs or tissue. These organs masses were then compared with those of both the Asian and the ICRP reference adult male. Organ masses within both KTMAN-1 and KTMAN-2 showed differences within 40% of Asian and ICRP reference values, with the exception of the skin, gall bladder, and pancreas which displayed larger differences. The resulting three-dimensional binary file was ported to the Monte Carlo code MCNPX2.4 to calculate organ doses following external irradiation for illustrative purposes. Colon, lung, liver, and stomach absorbed doses, as well as the effective dose, for idealized photon irradiation geometries (anterior-posterior and right lateral) were determined, and then compared with data from two other tomographic phantoms (Asian and Caucasian), and stylized ORNL phantom. The armless KTMAN-1 can be applied to dosimetry for computed tomography or lateral x-ray examination, while the whole body KTMAN-2 can be used for radiation protection dosimetry.

Entities:  

Mesh:

Year:  2006        PMID: 16532944     DOI: 10.1118/1.2161405

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Evaluation of the use of surrogate tissues for calculating radiation dose to lymphatic nodes from external photon beams.

Authors:  Stephanie Lamart; Brian E Moroz; Choonsik Lee
Journal:  Radiat Prot Dosimetry       Date:  2013-07-11       Impact factor: 0.972

2.  ORGAN DOSE ESTIMATION ACCOUNTING FOR UNCERTAINTY FOR PEDIATRIC AND YOUNG ADULT CT SCANS IN THE UNITED KINGDOM.

Authors:  Choonsik Lee; Neige Journy; Brian E Moroz; Mark Little; Richard Harbron; Kieran McHugh; Mark Pearce; Amy Berrington de Gonzalez
Journal:  Radiat Prot Dosimetry       Date:  2019-07-01       Impact factor: 0.972

Review 3.  An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history.

Authors:  X George Xu
Journal:  Phys Med Biol       Date:  2014-08-21       Impact factor: 3.609

4.  Manufacturing and evaluation of a multi-purpose Iranian head and neck anthropomorphic phantom called MIHAN.

Authors:  Mohammad Ahmadi; Meysam Ramezani Anarestani; Sanaz Hariri Tabrizi; Zohreh Azma
Journal:  Med Biol Eng Comput       Date:  2021-07-16       Impact factor: 2.602

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.