Literature DB >> 34268670

Manufacturing and evaluation of a multi-purpose Iranian head and neck anthropomorphic phantom called MIHAN.

Mohammad Ahmadi1, Meysam Ramezani Anarestani2, Sanaz Hariri Tabrizi3, Zohreh Azma1.   

Abstract

A new multi-purpose Iranian head and neck (MIHAN) anthropomorphic phantom was designed and manufactured to be used in diagnostic and therapeutic applications. Geometry of MIHAN phantom was determined based on the average dimensions acquired by CT scans of twenty patients without any medical problems in their head and neck site. Because the phantom was expected to be used with different modalities with a wide range of photon energies, attenuation coefficients of some selected materials were determined using Monte Carlo simulation. Based on analytical and simulation results, acrylonitrile butadiene styrene (ABS) and polylactic acid (PLA) were found suitable choices for soft and bony tissues, respectively. They were used in the 3D printer to build the phantom. The suitability of the materials was checked by CT number value comparison between the organs included in the phantom and the corresponding body tissues and also film dosimetry of a typical intensity-modulated radiation therapy (IMRT) plan.. Hounsfield Unit agreement and 95% ± 2% pass rate for the IMRT plan verification proved the suitability of material selection. Also, the film dosimetry showed feasibility of using MIHAN in radiotherapy plan verification workflow. In addition, PLA was introduced as a spongy bone tissue substitute for the first time.
© 2021. International Federation for Medical and Biological Engineering.

Entities:  

Keywords:  Anthropomorphic phantom; Dosimetry; Nuclear medicine; Radiation therapy; Tissue-equivalent

Year:  2021        PMID: 34268670     DOI: 10.1007/s11517-021-02394-y

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  11 in total

1.  Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code.

Authors:  Daryoush Sheikh-Bagheri; D W O Rogers
Journal:  Med Phys       Date:  2002-03       Impact factor: 4.071

2.  Development and test of sets of 3D printed age-specific thyroid phantoms for 131I measurements.

Authors:  Tiffany Beaumont; Pedro Caldeira Ideias; Maeva Rimlinger; David Broggio; Didier Franck
Journal:  Phys Med Biol       Date:  2017-03-07       Impact factor: 3.609

3.  Precise radiochromic film dosimetry using a flat-bed document scanner.

Authors:  Slobodan Devic; Jan Seuntjens; Edwin Sham; Ervin B Podgorsak; C Ross Schmidtlein; Assen S Kirov; Christopher G Soares
Journal:  Med Phys       Date:  2005-07       Impact factor: 4.071

4.  Design and implementation of an anthropomorphic quality assurance phantom for intensity-modulated radiation therapy for the Radiation Therapy Oncology Group.

Authors:  Andrea Molineu; David S Followill; Peter A Balter; William F Hanson; Michael T Gillin; M Saiful Huq; Avraham Eisbruch; Geoffrey S Ibbott
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-10-01       Impact factor: 7.038

5.  Development of the two Korean adult tomographic computational phantoms for organ dosimetry.

Authors:  Choonsik Lee; Choonik Lee; Sang-Hyun Park; Jai-Ki Lee
Journal:  Med Phys       Date:  2006-02       Impact factor: 4.071

6.  Marvin: an anatomical phantom for dosimetric evaluation of complex radiotherapy of the head and neck.

Authors:  A H Aitkenhead; C G Rowbottom; R I Mackay
Journal:  Phys Med Biol       Date:  2013-09-13       Impact factor: 3.609

7.  3D printer generated thorax phantom with mobile tumor for radiation dosimetry.

Authors:  Rulon Mayer; Peter Liacouras; Andrew Thomas; Minglei Kang; Liyong Lin; Charles B Simone
Journal:  Rev Sci Instrum       Date:  2015-07       Impact factor: 1.523

8.  Design and implementation of a prototype head and neck phantom for the performance evaluation of gamma imaging systems.

Authors:  Mohammed S Alqahtani; John E Lees; Sarah L Bugby; Piyal Samara-Ratna; Aik H Ng; Alan C Perkins
Journal:  EJNMMI Phys       Date:  2017-07-06

9.  Technical Note: Development of a 3D printed subresolution sandwich phantom for validation of brain SPECT analysis.

Authors:  Ian S Negus; Robin B Holmes; Kirsty C Jordan; David A Nash; Gareth C Thorne; Margaret Saunders
Journal:  Med Phys       Date:  2016-09       Impact factor: 4.071

10.  Design and implementation of a head-and-neck phantom for system audit and verification of intensity-modulated radiation therapy.

Authors:  Gareth J Webster; Mark J Hardy; Carl G Rowbottom; Ranald I Mackay
Journal:  J Appl Clin Med Phys       Date:  2008-04-16       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.