Literature DB >> 10947623

Factors affecting perfusionists' decisions on equipment utilization: results of a United States survey.

A H Stammers1, B L Mejak, E D Rauch, S N Vang, T W Viessman.   

Abstract

The decision to utilize extracorporeal equipment is influenced by a number of factors, including clinical efficacy, cost effectiveness, and personal judgment. The purpose of this study was to report the results of a national survey that examined factors affecting perfusionists' decisions on equipment utilization. An 80-question survey was mailed to chief perfusionists at 1030 U.S. hospitals performing open-heart surgery. 524 completed surveys were returned, which represented 797 hospitals (78.8%) and 671,290 procedures over a 2-year period (July 1996-June 1998). Within the survey, 36 questions pertained to equipment utilization and served as the basis for this report. The perfusion equipment that had seen the greatest reduction in use were; heparin-coated circuits (HCC) (12.0%), in-line blood gas monitors (9.7%), soft-shell venous reservoirs (SSVR) (7.2%), and in-line arterial hemoglobin monitors (6.3%). Cost was the major determinant affecting the decision for the following devices: in-line blood gas monitors (82.4%), cardioplegia in-line delivery filters (75.0%), in-line arterial hemoglobin monitors (69.7%), HCC (55.6%), and SSVR (43.2). Ineffectiveness was the major reason reported for discontinuation of arterial-line bubble traps (64.7%), venous reservoir level detectors (50.0%), and arterial-line pressure manometers with pump shutdown (50.0%). 438 respondents discontinued use of one or more of 29 different devices during the past 2 years. Cost was the major reason in 52.7% of the cases, ineffectiveness in 33.1%, and 14.2% were in a category labeled "other." The pressures brought upon by the changing healthcare structure have influenced perfusionists' equipment selection, with cost being a major factor affecting clinical decisions for certain device utilization.

Mesh:

Year:  2000        PMID: 10947623

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  10 in total

1.  Disconnection of Cobe SMARxT tubing from the venous outlet of the Terumo Capiox SX25RX oxygenator during cardiopulmonary bypass.

Authors:  Jane Ottens; Robert A Baker; Andrew J Sanderson; Richard F Newland
Journal:  J Extra Corpor Technol       Date:  2010-06

2.  Improved outcomes during cardiac surgery: a multifactorial enhancement of cardiopulmonary bypass techniques.

Authors:  Cody C Trowbridge; Alfred H Stammers; G Craig Wood; James D Murdock; Myra Klayman; Bianca R Yen; Edward Woods; Christian Gilbert
Journal:  J Extra Corpor Technol       Date:  2005-06

3.  Australian and New Zealand perfusion survey: equipment and monitoring.

Authors:  Robert A Baker; Timothy W Willcox
Journal:  J Extra Corpor Technol       Date:  2006-09

4.  Surveys and safety in perfusion practice.

Authors:  Timothy W Willcox; Robert A Baker
Journal:  J Extra Corpor Technol       Date:  2007-09

5.  Update on pediatric perfusion practice in North America: 2005 survey.

Authors:  Robert C Groom; Shane Froebe; Janine Martin; Michael J Manfra; John E Cormack; Catherine Morse; Andreas H Taenzer; Reed D Quinn
Journal:  J Extra Corpor Technol       Date:  2005-12

6.  Getting it right: optimizing the patient and technique for the procedure.

Authors:  Alfred H Stammers
Journal:  J Extra Corpor Technol       Date:  2009-12

7.  International Pediatric Perfusion Practice: 2016 Survey Results.

Authors:  Ashley Walcƶak; Thomas Klein; Jordan Voss; Vincent Olshove; Rajeev Gupta; Tatiana Averina; Luiz Caneo; Robert Groom
Journal:  J Extra Corpor Technol       Date:  2021-03

8.  International pediatric perfusion practice: 2011 survey results.

Authors:  Brian Harvey; Kenneth G Shann; David Fitzgerald; Brian Mejak; Donald S Likosky; Luc Puis; Robert A Baker; Robert C Groom
Journal:  J Extra Corpor Technol       Date:  2012-12

9.  Improving cardiopulmonary bypass: does continuous blood gas monitoring have a role to play?

Authors:  Jane Ottens; Sigrid C Tuble; Andrew J Sanderson; John L Knight; Robert A Baker
Journal:  J Extra Corpor Technol       Date:  2010-09

10.  Clinical evaluation of the ABL-77 for point-of-care analysis in the cardiovascular operating room.

Authors:  Jack S Prichard; John S French; Nestor Alvar
Journal:  J Extra Corpor Technol       Date:  2006-06
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.