Literature DB >> 16523296

Diagnostic accuracy of the Retinal Thickness Analyser: differentiation between normal eyes and eyes with glaucoma or macular pathologies.

Philip Maier1, Jens Funk.   

Abstract

BACKGROUND: The Retinal Thickness Analyser (RTA) is intended to detect glaucomatous changes as well as macular pathologies at the posterior pole. We determined the diagnostic accuracy for eyes with manifest glaucoma or macular diseases.
METHODS: We examined 71 eyes with long-term, established eye conditions. Included were 28 eyes with glaucoma, 21 with different macular diseases and 22 normal eyes. All examinations were evaluated in a blind-test by RTA experts without any clinical information on the patients. After comparison of the RTA interpretation with the clinical diagnosis, we determined sensitivity, specificity, positive and negative predictive values.
RESULTS: Of 71 examinations, 15 (21%) were not interpretable. If these results are excluded, the following diagnostic accuracy values were calculated for glaucoma and macular disorders respectively: sensitivity 75 and 59%, specificity 55 and 97%, positive predictive value 48 and 90% and negative predictive value 80 and 84%. These values were not significantly different when both eyes of each patient were included in the final analysis (n=133).
CONCLUSION: The diagnostic values of the RTA determined in this case control study were not satisfactory. However, no clinical information was used in the assessment. The extent to which additional clinical information increases the diagnostic value remains to be determined.

Entities:  

Mesh:

Year:  2006        PMID: 16523296     DOI: 10.1007/s00417-006-0288-4

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  17 in total

1.  Quantitative mapping of the retinal thickness at the posterior pole in chronic open angle glaucoma.

Authors:  P Brusini; C Tosoni; F Miani
Journal:  Acta Ophthalmol Scand Suppl       Date:  2000

2.  Comparison of optic nerve imaging methods to distinguish normal eyes from those with glaucoma.

Authors:  Michael J Greaney; Douglas C Hoffman; David F Garway-Heath; Mamdouh Nakla; Anne L Coleman; Joseph Caprioli
Journal:  Invest Ophthalmol Vis Sci       Date:  2002-01       Impact factor: 4.799

3.  Discriminating between normal and glaucomatous eyes using the Heidelberg Retina Tomograph, GDx Nerve Fiber Analyzer, and Optical Coherence Tomograph.

Authors:  L M Zangwill; C Bowd; C C Berry; J Williams; E Z Blumenthal; C A Sánchez-Galeana; C Vasile; R N Weinreb
Journal:  Arch Ophthalmol       Date:  2001-07

4.  Comparison of foveal thickness measured with the retinal thickness analyzer and optical coherence tomography.

Authors:  A S Neubauer; S Priglinger; S Ullrich; M Bechmann; M J Thiel; M W Ulbig; A Kampik
Journal:  Retina       Date:  2001       Impact factor: 4.256

Review 5.  Macular disease and optical coherence tomography.

Authors:  J G Coker; J S Duker
Journal:  Curr Opin Ophthalmol       Date:  1996-06       Impact factor: 3.761

6.  Quantitative analysis of foveal retinal thickness in diabetic retinopathy with the scanning retinal thickness analyzer.

Authors:  T Yasukawa; J Kiryu; A Tsujikawa; J Dong; I Suzuma; H Takagi; Y Ogura
Journal:  Retina       Date:  1998       Impact factor: 4.256

7.  [Measurement of human retinal thickness at posterior pole with retinal thickness analyzer in normal and glaucomatous eyes].

Authors:  Z Yang; S Du
Journal:  Zhonghua Yan Ke Za Zhi       Date:  2000-03

8.  Using optical imaging summary data to detect glaucoma.

Authors:  C Sanchez-Galeana; C Bowd; E Z Blumenthal; P A Gokhale; L M Zangwill; R N Weinreb
Journal:  Ophthalmology       Date:  2001-10       Impact factor: 12.079

9.  Quantitative analysis of diabetic macular edema after scatter laser photocoagulation with the scanning retinal thickness analyzer.

Authors:  A Tsujikawa; J Kiryu; J Dong; T Yasukawa; I Suzuma; H Takagi; Y Ogura
Journal:  Retina       Date:  1999       Impact factor: 4.256

10.  Comparison of Heidelberg Retina Tomograph II and Retinal Thickness Analyzer in the assessment of diabetic macular edema.

Authors:  Kit Guan; Chris Hudson; John G Flanagan
Journal:  Invest Ophthalmol Vis Sci       Date:  2004-02       Impact factor: 4.799

View more
  1 in total

1.  [Health-economic aspects of glaucoma screening].

Authors:  C Hirneiss; A Niedermaier; M Kernt; A Kampik; A S Neubauer
Journal:  Ophthalmologe       Date:  2010-02       Impact factor: 1.059

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.