Literature DB >> 16518965

Clinical performance of the new rRoche COBAS TaqMan HCV Test and High Pure System for extraction, detection and quantitation of HCV RNA in plasma and serum.

Huub C r Gelderblom1, Sandra Menting, Marcel G Beld.   

Abstract

We evaluated the Roche COBAS TaqMan HCV Test For Use With The High Pure System (TaqMan HPS; Roche Diagnostics), for the extraction, detection and quantitation of hepatitis C virus (HCV) RNA in serum or plasma of HCV-infected individuals. The TaqMan HPS is a real-time PCR assay with a reported linear dynamic range of 3.0x10(1) to 2.0x10(8) HCV RNA IU/ml, and a reported lower limit of detection (LLD) of 10 IU/ml. Calculation of the HCV RNA titre is based upon an external standard curve in the presence of an internal control. Intra-assay and inter-assay variation were small in reference panel members with HCV RNA > or =100 IU/ml. Genotype performance and quantitative correlation between the TaqMan HPS and the bDNA (VERSANT HCV 3.0 assay; Bayer Diagnostics), assessed in 59 patient samples, were good for HCV genotype 1 but poor for genotypes 2, 3 and 4. For genotypes 2, 3 and 4, values obtained from the TaqMan HPS were in general 0.5 log lower than those from the bDNA. Sensitivity was poor in low viral titre samples of genotypes 1, 2, 3 and 4. The LLD (95%) was estimated at 41 HCV RNA IU/ml for genotype 4. The TaqMan HPS underestimates HCV RNA at all levels in plasma and serum from HCV-infected individuals, and the LLD should be reconsidered. This is clinically relevant because underestimation of HCV RNA levels during therapy may lead physicians into making incorrect treatment decisions.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16518965

Source DB:  PubMed          Journal:  Antivir Ther        ISSN: 1359-6535


  9 in total

1.  Performance of the novel Qiagen artus QS-RGQ viral load assays compared to that of the Abbott RealTime system with genetically diversified HIV and hepatitis C Virus plasma specimens.

Authors:  Jan Felix Drexler; Ulrike Reber; Andrea Wuttkopf; Anna Maria Eis-Hübinger; Christian Drosten
Journal:  J Clin Microbiol       Date:  2012-03-07       Impact factor: 5.948

2.  Multicenter trials need to use the same assay for hepatitis C virus viral load determination.

Authors:  Syria Laperche; Françoise Bouchardeau; Vincent Thibault; Bruno Pozzetto; Sophie Vallet; Arielle R Rosenberg; Anne-Marie Roque-Afonso; Michèle Gassin; Françoise Stoll-Keller; Pascale Trimoulet; Elyanne Gault; Bruno Chanzy; Bernard Mercier; Michel Branger; Jean-Michel Pawlotsky; Cécile Henquell; Françoise Lunel; Catherine Gaudy-Graffin; Sophie Alain; Marie-Laure Chaix; Gilles Duverlie; Jacques Izopet; Jean-Jacques Lefrère
Journal:  J Clin Microbiol       Date:  2007-10-03       Impact factor: 5.948

3.  Multicenter evaluation of the new Abbott RealTime assays for quantitative detection of human immunodeficiency virus type 1 and hepatitis C virus RNA.

Authors:  M Schutten; D Peters; N K T Back; M Beld; K Beuselinck; V Foulongne; A-M Geretti; L Pandiani; C Tiemann; H G M Niesters
Journal:  J Clin Microbiol       Date:  2007-04-04       Impact factor: 5.948

4.  Performance characteristics of a quantitative hepatitis C virus RNA assay using COBAS AmpliPrep total nucleic acid isolation and COBAS taqman hepatitis C virus analyte-specific reagent.

Authors:  Michael S Forman; Alexandra Valsamakis
Journal:  J Mol Diagn       Date:  2008-02-14       Impact factor: 5.568

5.  Comparison of performance characteristics of three real-time reverse transcription-PCR test systems for detection and quantification of hepatitis C virus.

Authors:  M Fernanda Sábato; Mitchell L Shiffman; Michael R Langley; David S Wilkinson; Andrea Ferreira-Gonzalez
Journal:  J Clin Microbiol       Date:  2007-06-13       Impact factor: 5.948

6.  A novel diagnostic target in the hepatitis C virus genome.

Authors:  Jan Felix Drexler; Bernd Kupfer; Nadine Petersen; Rejane Maria Tommasini Grotto; Silvia Maria Corvino Rodrigues; Klaus Grywna; Marcus Panning; Augustina Annan; Giovanni Faria Silva; Jill Douglas; Evelyn S C Koay; Heidi Smuts; Eduardo M Netto; Peter Simmonds; Maria Inês de Moura Campos Pardini; W Kurt Roth; Christian Drosten
Journal:  PLoS Med       Date:  2009-02-10       Impact factor: 11.069

7.  Accurate detection and quantification of the fish viral hemorrhagic Septicemia virus (VHSv) with a two-color fluorometric real-time PCR assay.

Authors:  Lindsey R Pierce; James C Willey; Vrushalee V Palsule; Jiyoun Yeo; Brian S Shepherd; Erin L Crawford; Carol A Stepien
Journal:  PLoS One       Date:  2013-08-20       Impact factor: 3.240

8.  A multiplex two-color real-time PCR method for quality-controlled molecular diagnostic testing of FFPE samples.

Authors:  Jiyoun Yeo; Erin L Crawford; Thomas M Blomquist; Lauren M Stanoszek; Rachel E Dannemiller; Jill Zyrek; Luis E De Las Casas; Sadik A Khuder; James C Willey
Journal:  PLoS One       Date:  2014-02-21       Impact factor: 3.240

9.  Diagnostic Accuracy of the HemoCue Hb 301, STAT-Site MHgb and URIT-12 Point-of-Care Hemoglobin Meters in a Central Laboratory and a Community Based Clinic in Durban, South Africa.

Authors:  Manjeetha Jaggernath; Rumallen Naicker; Savathree Madurai; Mark A Brockman; Thumbi Ndung'u; Huub C Gelderblom
Journal:  PLoS One       Date:  2016-04-05       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.