Literature DB >> 16517847

Comparison of conventional PCR with real-time PCR and branched DNA-based assays for hepatitis C virus RNA quantification and clinical significance for genotypes 1 to 5.

Christoph Sarrazin1, Barbara C Gärtner, Dorothea Sizmann, Rainer Babiel, Ulrike Mihm, Wolf Peter Hofmann, Michael von Wagner, Stefan Zeuzem.   

Abstract

The key parameter for diagnosis and management of hepatitis C virus (HCV) infection is HCV RNA. Standardization of HCV RNA assays to IU is mainly based on genotype 1 panels. Little is known about the variability of commercially available HCV RNA assays for quantification of different genotypes. Two real-time reverse transcription (RT)-PCR assays (COBAS TaqMan HCV Test for use with the High-Pure System [HPS/CTM] and COBAS Ampliprep/COBAS TaqMan HCV Test [CAP/CTM]), one standard RT-PCR assay (COBAS Amplicor HCV Monitor 2.0 [CAM]), and one signal amplification assay (Versant Quantitative 3.0 [branched DNA [bDNA]]) were compared for quantification of genotypes 1 to 5 (n = 108). Using CAM as a reference assay for genotype 1-infected patients, the mean interassay differences compared with CAP/CTM, HPS/CTM, and bDNA were 0.16, -0.13, and -0.48 log(10) IU/ml HCV RNA, respectively. Comparison of CAM with CAP/CTM, HPS/CTM, and bDNA for the remaining genotypes showed the following results, respectively: 2a/c, -0.24, -0.78, and -0.49; 2b, -0.21, -0.18, and -0.64; 3a, 0.13, -1.04, and -0.55; 4, -0.52, -1.51, and -0.05; and 5, -0.28, -1.00, and -0.24 log IU/ml HCV RNA. A correct decision for treatment discontinuation in genotype 1 patients at week 12 was possible only when the same assay was used at baseline and week 12. Comparison of CAM with the CAP/CTM assay showed equal quantifications of genotype 1, 2, 3, and 5 samples, while genotype 4 samples were slightly underestimated. For the HPS/CTM assay, a significant underestimation of the HCV RNA concentrations of genotypes 2a/c, 3, 4, and 5 was observed. For the bDNA assay, a constant lower quantification of genotypes 1 to 3 was detected.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16517847      PMCID: PMC1393102          DOI: 10.1128/JCM.44.3.729-737.2006

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  29 in total

1.  Performance of the COBAS AMPLICOR HCV MONITOR test, version 2.0, an automated reverse transcription-PCR quantitative system for hepatitis C virus load determination.

Authors:  G Gerken; T Rothaar; M G Rumi; R Soffredini; M Trippler; M J Blunk; A Butcher; S Soviero; G Colucci
Journal:  J Clin Microbiol       Date:  2000-06       Impact factor: 5.948

2.  Quantitation of hepatitis C virus RNA by third generation branched DNA-based signal amplification assay.

Authors:  R S Ross; S Viazov; S Sarr; S Hoffmann; A Kramer; M Roggendorf
Journal:  J Virol Methods       Date:  2002-03       Impact factor: 2.014

3.  Performance of the New Bayer VERSANT HCV RNA 3.0 assay for quantitation of hepatitis C virus RNA in plasma and serum: conversion to international units and comparison with the Roche COBAS Amplicor HCV Monitor, Version 2.0, assay.

Authors:  Marcel Beld; Roel Sentjens; Sjoerd Rebers; Christine Weegink; Jan Weel; Cees Sol; René Boom
Journal:  J Clin Microbiol       Date:  2002-03       Impact factor: 5.948

4.  Peginterferon-alpha-2a (40KD) and ribavirin for 16 or 24 weeks in patients with genotype 2 or 3 chronic hepatitis C.

Authors:  Michael von Wagner; Miriam Huber; Thomas Berg; Holger Hinrichsen; Jens Rasenack; Tobias Heintges; Alexandra Bergk; Christine Bernsmeier; Dieter Häussinger; Eva Herrmann; Stefan Zeuzem
Journal:  Gastroenterology       Date:  2005-08       Impact factor: 22.682

5.  Prospective multicenter clinical evaluation of AMPLICOR and COBAS AMPLICOR hepatitis C virus tests.

Authors:  F S Nolte; M W Fried; M L Shiffman; A Ferreira-Gonzalez; C T Garrett; E R Schiff; S J Polyak; D R Gretch
Journal:  J Clin Microbiol       Date:  2001-11       Impact factor: 5.948

6.  Viral kinetics in patients with chronic hepatitis C treated with standard or peginterferon alpha2a.

Authors:  S Zeuzem; E Herrmann; J H Lee; J Fricke; A U Neumann; M Modi; G Colucci; W K Roth
Journal:  Gastroenterology       Date:  2001-05       Impact factor: 22.682

Review 7.  Hepatitis C virus kinetics.

Authors:  E Herrmann; A U Neumann; J M Schmidt; S Zeuzem
Journal:  Antivir Ther       Date:  2000-06

8.  Improved version 2.0 qualitative and quantitative AMPLICOR reverse transcription-PCR tests for hepatitis C virus RNA: calibration to international units, enhanced genotype reactivity, and performance characteristics.

Authors:  S C Lee; A Antony; N Lee; J Leibow; J Q Yang; S Soviero; K Gutekunst; M Rosenstraus
Journal:  J Clin Microbiol       Date:  2000-11       Impact factor: 5.948

9.  Peginterferon alfa-2b plus ribavirin compared with interferon alfa-2b plus ribavirin for initial treatment of chronic hepatitis C: a randomised trial.

Authors:  M P Manns; J G McHutchison; S C Gordon; V K Rustgi; M Shiffman; R Reindollar; Z D Goodman; K Koury; M Ling; J K Albrecht
Journal:  Lancet       Date:  2001-09-22       Impact factor: 79.321

10.  Comparative evaluation of the VERSANT HCV RNA 3.0, QUANTIPLEX HCV RNA 2.0, and COBAS AMPLICOR HCV MONITOR version 2.0 Assays for quantification of hepatitis C virus RNA in serum.

Authors:  Jeffrey J Germer; Paul J Heimgartner; Duane M Ilstrup; W Scott Harmsen; Greg D Jenkins; Robin Patel
Journal:  J Clin Microbiol       Date:  2002-02       Impact factor: 5.948

View more
  23 in total

1.  Variation analysis of six HCV viral load assays using low viremic HCV samples in the range of the clinical decision points for HCV protease inhibitors.

Authors:  F Wiesmann; G Naeth; C Sarrazin; A Berger; R Kaiser; R Ehret; H Knechten; P Braun
Journal:  Med Microbiol Immunol       Date:  2014-11-15       Impact factor: 3.402

2.  Development of a second version of the Cobas AmpliPrep/Cobas TaqMan hepatitis C virus quantitative test with improved genotype inclusivity.

Authors:  Johannes Vermehren; Giuseppe Colucci; Peter Gohl; Nabila Hamdi; Ahmed Ihab Abdelaziz; Ursula Karey; Diana Thamke; Heike Zitzer; Stefan Zeuzem; Christoph Sarrazin
Journal:  J Clin Microbiol       Date:  2011-07-13       Impact factor: 5.948

3.  Multicenter trials need to use the same assay for hepatitis C virus viral load determination.

Authors:  Syria Laperche; Françoise Bouchardeau; Vincent Thibault; Bruno Pozzetto; Sophie Vallet; Arielle R Rosenberg; Anne-Marie Roque-Afonso; Michèle Gassin; Françoise Stoll-Keller; Pascale Trimoulet; Elyanne Gault; Bruno Chanzy; Bernard Mercier; Michel Branger; Jean-Michel Pawlotsky; Cécile Henquell; Françoise Lunel; Catherine Gaudy-Graffin; Sophie Alain; Marie-Laure Chaix; Gilles Duverlie; Jacques Izopet; Jean-Jacques Lefrère
Journal:  J Clin Microbiol       Date:  2007-10-03       Impact factor: 5.948

4.  Genotype 3 diversity and quantification of hepatitis E virus RNA.

Authors:  Florence Abravanel; Karine Sandres-Saune; Sebastien Lhomme; Martine Dubois; Jean-Michel Mansuy; Jacques Izopet
Journal:  J Clin Microbiol       Date:  2012-01-11       Impact factor: 5.948

5.  Multicenter evaluation of the new Abbott RealTime assays for quantitative detection of human immunodeficiency virus type 1 and hepatitis C virus RNA.

Authors:  M Schutten; D Peters; N K T Back; M Beld; K Beuselinck; V Foulongne; A-M Geretti; L Pandiani; C Tiemann; H G M Niesters
Journal:  J Clin Microbiol       Date:  2007-04-04       Impact factor: 5.948

6.  Evaluation of the Abbott investigational use only RealTime hepatitis C virus (HCV) assay and comparison to the Roche TaqMan HCV analyte-specific reagent assay.

Authors:  Michael T Pyne; Eric Q Konnick; Amit Phansalkar; David R Hillyard
Journal:  J Clin Microbiol       Date:  2009-07-22       Impact factor: 5.948

7.  Hepatitis C virus RNA quantitation in venous and capillary small-volume whole-blood samples.

Authors:  Tony Bruns; Katrin Steinmetzer; Eugen Ermantraut; Andreas Stallmach
Journal:  J Clin Microbiol       Date:  2009-08-19       Impact factor: 5.948

8.  Performance characteristics of a quantitative hepatitis C virus RNA assay using COBAS AmpliPrep total nucleic acid isolation and COBAS taqman hepatitis C virus analyte-specific reagent.

Authors:  Michael S Forman; Alexandra Valsamakis
Journal:  J Mol Diagn       Date:  2008-02-14       Impact factor: 5.568

9.  Improved COBAS TaqMan hepatitis C virus test (Version 2.0) for use with the High Pure system: enhanced genotype inclusivity and performance characteristics in a multisite study.

Authors:  G Colucci; J Ferguson; C Harkleroad; S Lee; D Romo; S Soviero; J Thompson; M Velez; A Wang; Y Miyahara; S Young; C Sarrazin
Journal:  J Clin Microbiol       Date:  2007-09-26       Impact factor: 5.948

10.  Differences between two real-time PCR-based hepatitis C virus (HCV) assays (RealTime HCV and Cobas AmpliPrep/Cobas TaqMan) and one signal amplification assay (Versant HCV RNA 3.0) for RNA detection and quantification.

Authors:  Johannes Vermehren; Annika Kau; Barbara C Gärtner; Reinhild Göbel; Stefan Zeuzem; Christoph Sarrazin
Journal:  J Clin Microbiol       Date:  2008-09-17       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.