Literature DB >> 11849694

Quantitation of hepatitis C virus RNA by third generation branched DNA-based signal amplification assay.

R S Ross1, S Viazov, S Sarr, S Hoffmann, A Kramer, M Roggendorf.   

Abstract

Quantitation of hepatitis C virus (HCV) RNA has become an important tool in different clinical settings and is used extensively for pretreatment evaluation of patients infected chronically with HCV. In this study, the performance characteristics of the third generation branched DNA-based signal amplification assay (bDNA 3.0) for HCV RNA quantitation were established. The new assay version showed an analytical specificity of 98%. Mean intra- and between-run imprecisions were 6.8 and 11.2%, respectively. The assay was linear over its entire dynamic range. Quantitation appeared to be unaffected by the genotypic variability of HCV. A comparison of bDNA 3.0 with the second generation bDNA assay calibrated against the international WHO HCV RNA standard, and the PCR-based Cobas Amplicor HCV Monitor 2.0 revealed a fairly good correlation among the assays. Twenty-nine and 11% of the paired quantitative results differed by more than log(10)0.5 (i.e. three-fold). All three assays after calibration against the WHO standard also yielded clinically comparable results with regard to the tailoring of interferon alpha/ribavirin treatment duration in patients infected by HCV genotypes 1, 4, and 5.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11849694     DOI: 10.1016/s0166-0934(01)00433-5

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  18 in total

Review 1.  Current therapy for hepatitis C.

Authors:  Mireen Friedrich-Rust; Stefan Zeuzem; Christoph Sarrazin
Journal:  Int J Colorectal Dis       Date:  2005-09-21       Impact factor: 2.571

2.  Hepatitis A, B, and C.

Authors:  R Gilson; M G Brook
Journal:  Sex Transm Infect       Date:  2006-12       Impact factor: 3.519

3.  Comparison of qualitative (COBAS AMPLICOR HCV 2.0 versus VERSANT HCV RNA) and quantitative (COBAS AMPLICOR HCV monitor 2.0 versus VERSANT HCV RNA 3.0) assays for hepatitis C virus (HCV) RNA detection and quantification: impact on diagnosis and treatment of HCV infections.

Authors:  Isabelle Desombere; Hans Van Vlierberghe; Sibyl Couvent; Filip Clinckspoor; Geert Leroux-Roels
Journal:  J Clin Microbiol       Date:  2005-06       Impact factor: 5.948

4.  Multicenter evaluation of the new Abbott RealTime assays for quantitative detection of human immunodeficiency virus type 1 and hepatitis C virus RNA.

Authors:  M Schutten; D Peters; N K T Back; M Beld; K Beuselinck; V Foulongne; A-M Geretti; L Pandiani; C Tiemann; H G M Niesters
Journal:  J Clin Microbiol       Date:  2007-04-04       Impact factor: 5.948

5.  Second-generation Cobas AmpliPrep/Cobas TaqMan HCV quantitative test for viral load monitoring: a novel dual-probe assay design.

Authors:  Heike Zitzer; Gabrielle Heilek; Karine Truchon; Simone Susser; Johannes Vermehren; Dorothea Sizmann; Bryan Cobb; Christoph Sarrazin
Journal:  J Clin Microbiol       Date:  2012-12-12       Impact factor: 5.948

6.  Simultaneous runs of the Bayer VERSANT HIV-1 version 3.0 and HCV bDNA version 3.0 quantitative assays on the system 340 platform provide reliable quantitation and improved work flow.

Authors:  Tarek Elbeik; Norman Markowitz; Patricia Nassos; Uday Kumar; Scott Beringer; Barbara Haller; Valerie Ng
Journal:  J Clin Microbiol       Date:  2004-07       Impact factor: 5.948

7.  Variable ratio of hepatitis C virus RNA to viral core antigen in patient sera.

Authors:  Christian G Schüttler; Christine Thomas; Thomas Discher; Georg Friese; Jürgen Lohmeyer; Ralph Schuster; Stephan Schaefer; Wolfram H Gerlich
Journal:  J Clin Microbiol       Date:  2004-05       Impact factor: 5.948

8.  Comparison of the abbott 7000 and bayer 340 systems for measurement of hepatitis C virus load.

Authors:  Helene C Highbarger; Zonghui Hu; Shyam Kottilil; Julia A Metcalf; Michael A Polis; M B Vasudevachari; H Clifford Lane; Robin L Dewar
Journal:  J Clin Microbiol       Date:  2007-06-27       Impact factor: 5.948

9.  Multicenter evaluation of the performance characteristics of the bayer VERSANT HCV RNA 3.0 assay (bDNA).

Authors:  Tarek Elbeik; Johan Surtihadi; Mark Destree; Jed Gorlin; Mark Holodniy; Saeed A Jortani; Ken Kuramoto; Valerie Ng; Roland Valdes; Alexandra Valsamakis; Norah A Terrault
Journal:  J Clin Microbiol       Date:  2004-02       Impact factor: 5.948

10.  Differences between two real-time PCR-based hepatitis C virus (HCV) assays (RealTime HCV and Cobas AmpliPrep/Cobas TaqMan) and one signal amplification assay (Versant HCV RNA 3.0) for RNA detection and quantification.

Authors:  Johannes Vermehren; Annika Kau; Barbara C Gärtner; Reinhild Göbel; Stefan Zeuzem; Christoph Sarrazin
Journal:  J Clin Microbiol       Date:  2008-09-17       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.