Literature DB >> 18780121

"Sandwich" plating for intra-articular distal radius fractures with volar and dorsal metaphyseal comminution.

Charles S Day1, Atul F Kamath, Eric Makhni, Jerome Jean-Gilles, David Zurakowski.   

Abstract

INTRODUCTION: Intra-articular distal radius fractures with volar and dorsal comminution present a special challenge to the hand surgeon.
METHODS: Ten patients formed the study cohort. All plates were low profile and stainless steel. Radiographic parameters, range of motion, and strength compared to the uninjured side were recorded. Functional outcome was evaluated by Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire and Gartland and Werley scoring system.
RESULTS: Median age at surgery was 58 years (range, 24 to 86). Mean follow-up was 17 months (range, 12 to 28). According to the AO classification system, there were three type C2 and seven type C3 fractures. Median preoperative dorsal angulation was 24 deg; median postoperative dorsal angulation was 3 deg. Eighty percent (8) of the fractures also had an intra-articular step-off or gap, all of which were corrected to neutral by the procedure. Compared with the contralateral side, mean extension and flexion were 73 and 75%, respectively, pronation and supination were 95 and 88%, respectively, and grip strength and thumb pinch were 72 and 87%, respectively. Mean postoperative DASH score was 16 points, and 70% (7) of the patients had Gartland and Werley scores of good or excellent. None of the patients needed to have their plates removed, and no extensor tendon rupture was reported.
CONCLUSIONS: The "sandwich" plating technique is an effective method of regaining near-anatomic reconstruction of intra-articular, volarly and dorsally comminuted distal radius fractures. Results from this study demonstrate that patients can expect to regain about 80% of their range of motion and strength. Moreover, 70% of the patients will have good to excellent functional outcomes. This is the first study to examine range of motion and functional outcome of low-profile "sandwich" plating without plate removal.

Entities:  

Year:  2007        PMID: 18780121      PMCID: PMC2528974          DOI: 10.1007/s11552-007-9061-3

Source DB:  PubMed          Journal:  Hand (N Y)        ISSN: 1558-9447


  20 in total

1.  Evaluation of healed Colles' fractures.

Authors:  J J GARTLAND; C W WERLEY
Journal:  J Bone Joint Surg Am       Date:  1951-10       Impact factor: 5.284

2.  Treatment of displaced intra-articular fractures of the distal end of the radius with plates.

Authors:  F Fitoussi; W Y Ip; S P Chow
Journal:  J Bone Joint Surg Am       Date:  1997-09       Impact factor: 5.284

3.  The treatment of unstable distal radius fractures with volar fixation.

Authors:  J L Orbay
Journal:  Hand Surg       Date:  2000-12

4.  Treatment of severely comminuted intra-articular fractures of the distal end of the radius by open reduction and combined internal and external fixation.

Authors:  R A Rogachefsky; S R Lipson; B Applegate; E A Ouellette; A M Savenor; J A McAuliffe
Journal:  J Bone Joint Surg Am       Date:  2001-04       Impact factor: 5.284

5.  Use of a distraction plate for distal radial fractures with metaphyseal and diaphyseal comminution.

Authors:  David S Ruch; T Adam Ginn; Charles C Yang; Beth P Smith; Julia Rushing; Douglas P Hanel
Journal:  J Bone Joint Surg Am       Date:  2005-05       Impact factor: 5.284

6.  Open reduction and internal fixation for distal radius fractures.

Authors:  M L Missakian; W P Cooney; P C Amadio; H L Glidewell
Journal:  J Hand Surg Am       Date:  1992-07       Impact factor: 2.230

7.  Results of combined internal and external fixation for the treatment of severe AO-C3 fractures of the distal radius.

Authors:  R L Bass; W F Blair; P P Hubbard
Journal:  J Hand Surg Am       Date:  1995-05       Impact factor: 2.230

8.  Articular fractures of the distal radius.

Authors:  C P Melone
Journal:  Orthop Clin North Am       Date:  1984-04       Impact factor: 2.472

9.  Treatment of distal radius fractures with a low-profile dorsal plating system: an outcomes assessment.

Authors:  Paul M Simic; Jason Robison; Michael J Gardner; Richard H Gelberman; Andrew J Weiland; Martin I Boyer
Journal:  J Hand Surg Am       Date:  2006-03       Impact factor: 2.230

10.  Intra-articular fractures of the distal end of the radius in young adults.

Authors:  J L Knirk; J B Jupiter
Journal:  J Bone Joint Surg Am       Date:  1986-06       Impact factor: 5.284

View more
  3 in total

1.  Outcome following distally locked volar plating for distal radius fractures with metadiaphyseal involvement.

Authors:  Kristofer S Matullo; David G Dennison
Journal:  Hand (N Y)       Date:  2015-06

2.  A modified intrafocal pinning technique with three-dimensional planning to facilitate volar plating in dorsally comminuted AO/OTA C2 and C3 distal radius fractures.

Authors:  Xue-Yang Gui; Hong-Fei Shi; Jin Xiong; Yi-Xin Chen; Jun-Fei Wang; Jie Huang; Xu-Sheng Qiu; Yin-He Wang
Journal:  BMC Musculoskelet Disord       Date:  2021-04-23       Impact factor: 2.362

Review 3.  Combined Approach for Intra-articular Distal Radius Fracture: A Case Series and Literature Review.

Authors:  Hyoung-Seok Jung; Hyung-Chul Cho; Jae Sung Lee
Journal:  Clin Orthop Surg       Date:  2021-11-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.