Literature DB >> 29704082

Flexor pollicis longus tendon rupture by sandwiched underlying volar locking plate and distal radius.

Takuya Uemura1, Tadashi Okano2, Ema Onode2, Takuya Yokoi2, Kosuke Shintani2, Mitsuhiro Okada2, Hiroaki Nakamura2.   

Abstract

Flexor pollicis longus (FPL) tendon rupture is a major complication of volar locking plate fixation for distal radius fractures. The tendon rupture is usually caused by friction between the distal edge of the plate and the FPL tendon, and has been well detected recently with ultrasonography. Rarely, the volar locking plate itself entraps the FPL tendon, leading to its rupture. A 63-year-old man was consistently unable to flex his right thumb after previous surgery for a distal radius fracture at another hospital. Ultrasonography demonstrated loss of tendon gliding and unusual patterns of the FPL tendon. The tendon was sandwiched between the plate and the distal radius, and was penetrated by the distal locking screw, which was comparable to intraoperative findings of complete entrapment and rupture of the FPL tendon from the underlying plate. The tendon defects were repaired using a palmaris longus tendon graft after removing the screws and plate. Finally, he could flex his thumb actively with satisfaction. Unusual patterns of FPL tendon rupture buried under inadequate plate positioning must be recognized, as in this case. Ultrasonographic assessment is routinely recommended to visibly determine any FPL tendon damage after volar locking plate fixation for distal radius fractures.

Entities:  

Keywords:  Distal radius fracture; Flexor pollicis longus tendon; Locking plate; Tendon rupture; Ultrasonography

Mesh:

Year:  2018        PMID: 29704082     DOI: 10.1007/s10396-018-0882-1

Source DB:  PubMed          Journal:  J Med Ultrason (2001)        ISSN: 1346-4523            Impact factor:   1.314


  19 in total

1.  Flexor tendon injuries following locked volar plating of distal radius fractures.

Authors:  Andrew W Cross; Christopher C Schmidt
Journal:  J Hand Surg Am       Date:  2008-02       Impact factor: 2.230

2.  Flexor tendon problems after volar plate fixation of distal radius fractures.

Authors:  Mehdi N Adham; Margaret Porembski; Christine Adham
Journal:  Hand (N Y)       Date:  2009-03-13

3.  The treatment of unstable distal radius fractures with volar fixation.

Authors:  J L Orbay
Journal:  Hand Surg       Date:  2000-12

4.  Risk Assessment of Tendon Attrition Following Treatment of Distal Radius Fractures With Volar Locking Plates Using Audible Crepitus and Placement of the Plate: A Prospective Clinical Cohort Study.

Authors:  Hiroshi Yamazaki; Shigeharu Uchiyama; Masatoshi Komatsu; Shun Hashimoto; Hiroyuki Kato
Journal:  J Hand Surg Am       Date:  2015-05-02       Impact factor: 2.230

5.  Ultrasonic Evaluation of the Flexor Pollicis Longus Tendon Following Volar Plate Fixation for Distal Radius Fractures.

Authors:  Adnan Kara; Haluk Celik; Mujdat Bankaoglu; Yunus Oc; Murat Bulbul; Tahir Sadık Sugun
Journal:  J Hand Surg Am       Date:  2016-01-16       Impact factor: 2.230

6.  Fracture of the distal radius: risk factors for complications after locked volar plate fixation.

Authors:  Maximillian Soong; Roderick van Leerdam; Thierry G Guitton; Christopher Got; Julia Katarincic; David Ring
Journal:  J Hand Surg Am       Date:  2011-01       Impact factor: 2.230

7.  Evaluation of flexor pollicis longus tendon attrition using color Doppler imaging after volar plate fixation for distal radius fracture.

Authors:  Yoshitaka Tanaka; Hiroyuki Gotani; Koichi Yano; Kosuke Sasaki; Yoshitaka Hamada
Journal:  J Orthop Sci       Date:  2017-03-18       Impact factor: 1.601

8.  Asymptomatic Flexor Tendon Damages after Volar Locking Plate Fixation of Distal Radius Fractures.

Authors:  Susumu Tokunaga; Yoshihiro Abe
Journal:  J Hand Surg Asian Pac Vol       Date:  2017-03

9.  Transverse ultrasound assessment of the flexor pollicis longus tendon movement on the distal radius during wrist and finger motion in distal radius fracture with volar plating.

Authors:  Mitsuhiko Nanno; Norie Kodera; Yuji Tomori; Shinro Takai
Journal:  J Med Ultrason (2001)       Date:  2015-09-13       Impact factor: 1.314

Review 10.  Flexor tendon injuries following plate fixation of distal radius fractures: a systematic review of the literature.

Authors:  Saeed Asadollahi; Prue P A Keith
Journal:  J Orthop Traumatol       Date:  2013-05-14
View more
  1 in total

1.  Radiocarpal joint stiffness following surgical treatment for distal radius fractures: the incidence and associated factors.

Authors:  Lingde Kong; Yajie Zhai; Zuzhuo Zhang; Jian Lu; Bing Zhang; Dehu Tian
Journal:  J Orthop Surg Res       Date:  2020-08-11       Impact factor: 2.359

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.