Literature DB >> 1648757

Nonpalpable breast lesions: stereotactic automated large-core biopsies.

S H Parker1, J D Lovin, W E Jobe, B J Burke, K D Hopper, W F Yakes.   

Abstract

One hundred two patients with mammographically suspicious, nonpalpable lesions underwent stereotactic breast biopsy with a biopsy gun and an automated 14-gauge cutting needle. After biopsy, a localization wire was placed and surgical biopsy performed. There was agreement of the histologic results from the gun biopsy and the surgical biopsy specimens in 98 cases (96%), including 22 of 23 carcinomas (96%) (kappa = 0.936). The gun biopsy yielded findings that led to the correct diagnosis in two cases involving lesions that were missed at surgical biopsy; two lesions found at surgery were missed at gun biopsy. The results of this study suggest that the use of 14-gauge needles improves agreement between surgical and needle core biopsy findings and that stereotactic biopsy with an automated needle and gun can be an acceptable alternative to surgical biopsy in women with mammographically suspicious breast lesions.

Entities:  

Mesh:

Year:  1991        PMID: 1648757     DOI: 10.1148/radiology.180.2.1648757

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  30 in total

Review 1.  Stereotactic and ultrasound-guided breast biopsy.

Authors:  T H Helbich; W Matzek; M H Fuchsjäger
Journal:  Eur Radiol       Date:  2003-11-13       Impact factor: 5.315

2.  Spectral-domain low coherence interferometry/optical coherence tomography system for fine needle breast biopsy guidance.

Authors:  N V Iftimia; M Mujat; T Ustun; R D Ferguson; V Danthu; D X Hammer
Journal:  Rev Sci Instrum       Date:  2009-02       Impact factor: 1.523

Review 3.  MR imaging findings of benign and malignant circumscribed breast masses: part 2. Cystic circumscribed masses.

Authors:  Takayoshi Uematsu; Masako Kasami
Journal:  Jpn J Radiol       Date:  2009-12-25       Impact factor: 2.374

4.  Can galactography-guided stereotactic, 11-gauge, vacuum-assisted breast biopsy of intraductal lesions serve as an alternative to surgical biopsy?

Authors:  Caecilia S Reiner; Thomas H Helbich; Margaretha Rudas; Lothar Ponhold; Christopher C Riedl; Nina Kropf; Michael H Fuchsjäger
Journal:  Eur Radiol       Date:  2009-12       Impact factor: 5.315

5.  Surgical biopsy findings in patients with atypical hyperplasia diagnosed by stereotaxic core needle biopsy.

Authors:  I Tocino; B M Garcia; D Carter
Journal:  Ann Surg Oncol       Date:  1996-09       Impact factor: 5.344

6.  Stereotactic breast biopsy as an alternative to open excisional biopsy.

Authors:  M J Cross; W P Evans; G N Peters; J H Cheek; R C Jones; P Krakos
Journal:  Ann Surg Oncol       Date:  1995-05       Impact factor: 5.344

7.  Mammographically detected breast cancer. Benefits of stereotactic core versus wire localization biopsy.

Authors:  J H Yim; P Barton; B Weber; D Radford; J Levy; B Monsees; F Flanagan; J A Norton; G M Doherty
Journal:  Ann Surg       Date:  1996-06       Impact factor: 12.969

8.  Predictive factors for breast cancer in patients diagnosed atypical ductal hyperplasia at core needle biopsy.

Authors:  Byung Joo Chae; Ahwon Lee; Byung Joo Song; Sang Seol Jung
Journal:  World J Surg Oncol       Date:  2009-10-23       Impact factor: 2.754

9.  Fluorescence spectroscopy: an adjunct diagnostic tool to image-guided core needle biopsy of the breast.

Authors:  Changfang Zhu; Elizabeth S Burnside; Gale A Sisney; Lonie R Salkowski; Josephine M Harter; Bing Yu; Nirmala Ramanujam
Journal:  IEEE Trans Biomed Eng       Date:  2009-03-04       Impact factor: 4.538

10.  The accuracy of frozen section analysis in ultrasound- guided core needle biopsy of breast lesions.

Authors:  Andreas H Brunner; Thomas Sagmeister; Jolanta Kremer; Paul Riss; Hermann Brustmann
Journal:  BMC Cancer       Date:  2009-09-24       Impact factor: 4.430

View more