Literature DB >> 16481693

Model-based compensation for quantitative 123I brain SPECT imaging.

Yong Du1, Benjamin M W Tsui, Eric C Frey.   

Abstract

Previously we have developed a model-based method that can accurately estimate downscatter contamination from high-energy photons in 123I imaging. In this work we combined the model-based method with iterative reconstruction-based compensations for other image-degrading factors such as attenuation, scatter, the collimator-detector response function (CDRF) and partial volume effects to form a comprehensive method for performing quantitative 123I SPECT image reconstruction. In the model-based downscatter estimation method, photon scatter inside the object was modelled using the effective source scatter estimation (ESSE) technique, including contributions from all the photon emissions. The CDRFs, including the penetration and scatter components due to the high-energy 123I photons, were estimated using Monte Carlo (MC) simulations of point sources in air at various distances from the face of the collimator. The downscatter contamination was then compensated for during the iterative reconstruction by adding the estimated results to the projection steps. The model-based downscatter compensation (MBDC) was evaluated using MC simulated and experimentally acquired projection data. From the MC simulation, we found about 39% of the total counts in the energy window of 123I were attributed to the downscatter contamination, which reduced image contrast and caused a 1.5% to 10% overestimation of activities in various brain structures. Model-based estimates of the downscatter contamination were in good agreement with the simulated data. Compensation using MBDC removed the contamination and improved the image contrast and quantitative accuracy to that of the images obtained from 159 keV photons. The errors in absolute quantitation were reduced to within +/-3.5%. The striatal specific binding potential calculated based on the activity ratio to the background was also improved after MBDC. The errors were reduced from -4.5% to -10.93% without compensation to -0.55% to 4.87% after compensation. The model-based method provided accurate downscatter estimation and, when combined with iterative reconstruction-based compensations, accurate quantitation was obtained with minimal loss of precision.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16481693     DOI: 10.1088/0031-9155/51/5/016

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  30 in total

Review 1.  Brain single-photon emission CT physics principles.

Authors:  R Accorsi
Journal:  AJNR Am J Neuroradiol       Date:  2008-06-26       Impact factor: 3.825

2.  Quantitative evaluation of simultaneous reconstruction with model-based crosstalk compensation for 99mTc/123I dual-isotope simultaneous acquisition brain SPECT.

Authors:  Yong Du; Eric C Frey
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

3.  The impact of reconstruction method on the quantification of DaTSCAN images.

Authors:  John C Dickson; Livia Tossici-Bolt; Terez Sera; Kjell Erlandsson; Andrea Varrone; Klaus Tatsch; Brian F Hutton
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-01       Impact factor: 9.236

4.  Development and evaluation of a model-based downscatter compensation method for quantitative I-131 SPECT.

Authors:  Na Song; Yong Du; Bin He; Eric C Frey
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

5.  A Learned Reconstruction Network for SPECT Imaging.

Authors:  Wenyi Shao; Martin G Pomper; Yong Du
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-05-12

6.  Current pediatric administered activity guidelines for 99m Tc-DMSA SPECT based on patient weight do not provide the same task-based image quality.

Authors:  Ye Li; Shannon O'Reilly; Donika Plyku; S Ted Treves; Frederic Fahey; Yong Du; Xinhua Cao; Briana Sexton-Stallone; Justin Brown; George Sgouros; Wesley E Bolch; Eric C Frey
Journal:  Med Phys       Date:  2019-09-20       Impact factor: 4.071

7.  MIRD pamphlet No. 23: quantitative SPECT for patient-specific 3-dimensional dosimetry in internal radionuclide therapy.

Authors:  Yuni K Dewaraja; Eric C Frey; George Sgouros; A Bertrand Brill; Peter Roberson; Pat B Zanzonico; Michael Ljungberg
Journal:  J Nucl Med       Date:  2012-06-28       Impact factor: 10.057

Review 8.  Absolute quantification in SPECT.

Authors:  Philipp Ritt; Hans Vija; Joachim Hornegger; Torsten Kuwert
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-04-12       Impact factor: 9.236

Review 9.  Three-dimensional imaging-based radiobiological dosimetry.

Authors:  George Sgouros; Eric Frey; Richard Wahl; Bin He; Andrew Prideaux; Robert Hobbs
Journal:  Semin Nucl Med       Date:  2008-09       Impact factor: 4.446

10.  Extrastriatal binding of [¹²³I]FP-CIT in the thalamus and pons: gender and age dependencies assessed in a European multicentre database of healthy controls.

Authors:  Walter Koch; Marcus Unterrainer; Guoming Xiong; Peter Bartenstein; Markus Diemling; Andrea Varrone; John C Dickson; Livia Tossici-Bolt; Terez Sera; Susanne Asenbaum; Jan Booij; Ozlem L Kapucu; Andreas Kluge; Morten Ziebell; Jacques Darcourt; Flavio Nobili; Marco Pagani; Swen Hesse; Thierry Vander Borght; Koen Van Laere; Klaus Tatsch; Christian la Fougère
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-05-08       Impact factor: 9.236

View more