Literature DB >> 16480012

Twenty-year results of the Hancock II bioprosthesis.

Michael A Borger1, Joan Ivanov, Susan Armstrong, Debbie Christie-Hrybinsky, Christopher M Feindel, Tirone E David.   

Abstract

BACKGROUND AND AIM OF THE STUDY: The Hancock II bioprosthesis (HII) has several design features designed to increase its durability. The study aim was to determine very long-term outcomes for the HII valve in a large patient population.
METHODS: Long-term follow up was obtained by mail and/or telephone questionnaire of patients undergoing HII valve replacement surgery between 1982 and 2001 (n = 1,569). Follow up was complete on 1,568 patients (99.9%), and ranged from 0 to 250 months.
RESULTS: Isolated aortic valve replacement (AVR) was performed in 1,010 patients and mitral valve replacement (MVR) in 559. The average (+/- SD) age of patients was 67 +/- 11 years, and 65% were males. Long-term death occurred in 445 AVR patients and 275 MVR patients, of which 11% and 17%, respectively, were valve-related. Twenty-year freedom from thromboembolism (all results actuarial) was 79 +/- 3% after AVR and 83 +/- 3% after MVR; freedom from endocarditis was 91 +/- 5% and 85 +/- 5%, respectively. Twenty-year freedom from structural valve deterioration (SVD) was 73 +/- 16% and 39 +/- 9% in AVR patients aged > or = 65 years and < 65 years, respectively. Similarly, 20-year freedom from SVD was 59 +/- 11% and 27 +/- 9% in MVR patients aged > or = 65 years and < 65 years, respectively. When actual statistical techniques were applied (cumulative incidence), 20-year actual risk of SVD was 18 +/- 3% in all AVR patients and 23 +/- 3% in all MVR patients. Reoperation was required in 72 AVR patients, and was valve-related in 60. A total of 49 MVR patients underwent reoperation; 48 of these were valve-related.
CONCLUSION: The Hancock II bioprosthesis continues to show very good long-term results and durability, particularly in patients aged over 65 years.

Entities:  

Mesh:

Year:  2006        PMID: 16480012

Source DB:  PubMed          Journal:  J Heart Valve Dis        ISSN: 0966-8519


  11 in total

1.  Pulmonary valve replacement long after repair of tetralogy of Fallot.

Authors:  Yuichi Shiokawa; Hiromichi Sonoda; Yoshihisa Tanoue; Takahiro Nishida; Atsuhiro Nakashima; Ryuji Tominaga
Journal:  Gen Thorac Cardiovasc Surg       Date:  2012-05-08

2.  Aortic valve replacement vs. transcatheter aortic valve implantation: Patient selection.

Authors:  Jian Ye; Jia Lin Soon; John Webb
Journal:  Ann Cardiothorac Surg       Date:  2012-07

Review 3.  A look at recent improvements in the durability of tissue valves.

Authors:  Takahiro Nishida; Ryuji Tominaga
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-01-24

Review 4.  Artificial valves "up to date" in Japan.

Authors:  Shigehiko Tokunaga; Ryuji Tominaga
Journal:  J Artif Organs       Date:  2010-06-17       Impact factor: 1.731

5.  Durability of bioprosthetic cardiac valves.

Authors:  Grischa Hoffmann; Georg Lutter; Jochen Cremer
Journal:  Dtsch Arztebl Int       Date:  2008-02-22       Impact factor: 5.594

6.  Surgical management of chronic pulmonary regurgitation after relief of right ventricular outflow tract obstruction.

Authors:  Cheul Lee
Journal:  Korean Circ J       Date:  2012-01-31       Impact factor: 3.243

7.  The long-term results and changing patterns of biological valves at the mitral position in contemporary practice in Japan.

Authors:  Tomonobu Abe; Hideki Ito; Masato Mutsuga; Kazuro Fujimoto; Sachie Terazawa; Yuji Narita; Hideki Oshima; Akihiko Usui
Journal:  Nagoya J Med Sci       Date:  2016-12       Impact factor: 1.131

Review 8.  Mitral Valve Replacement-Current and Future Perspectives.

Authors:  Johan van der Merwe; Filip Casselman
Journal:  Open J Cardiovasc Surg       Date:  2017-07-13

9.  Prosthetic heart valve selection in women of childbearing age with acquired heart disease: a case report.

Authors:  Leonid Barbarash; Natalya Rutkovskaya; Olga Barbarash; Yuri Odarenko; Alexander Stasev; Evgenya Uchasova
Journal:  J Med Case Rep       Date:  2016-03-08

10.  A single-center 14-year follow-up study of the BalMedic® bovine pericardial bioprosthetic valve.

Authors:  Minghao Lin; Naiyan Gan; Jun Chen; Kai Lv; Shengfu Han; Huazhen Huang
Journal:  Ann Transl Med       Date:  2020-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.