Literature DB >> 20556626

Artificial valves "up to date" in Japan.

Shigehiko Tokunaga1, Ryuji Tominaga.   

Abstract

We have many choices when selecting artificial valves for valve replacement surgery. It is necessary to know the characteristics of the various prosthetic valves to make an appropriate decision for each valvular heart disease patient. In this review paper, we describe the features and benefits of the artificial valves available in Japan. Standard and new generation bioprostheses and mechanical prostheses are reviewed. The new technology of the catheter-delivery heart valve is also mentioned in this paper.

Entities:  

Mesh:

Year:  2010        PMID: 20556626     DOI: 10.1007/s10047-010-0507-y

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  36 in total

1.  Are stentless valves hemodynamically superior to stented valves? A prospective randomized trial.

Authors:  Gideon Cohen; George T Christakis; Campbell D Joyner; Christopher D Morgan; Miguel Tamariz; Naoji Hanayama; Hari Mallidi; J P Szalai; Marko Katic; Vivek Rao; Stephen E Fremes; Bernard S Goldman
Journal:  Ann Thorac Surg       Date:  2002-03       Impact factor: 4.330

2.  Age and valve size effect on the long-term durability of the Carpentier-Edwards aortic pericardial bioprosthesis.

Authors:  M K Banbury; D M Cosgrove; J A White; E H Blackstone; R W Frater; J E Okies
Journal:  Ann Thorac Surg       Date:  2001-09       Impact factor: 4.330

3.  Transapical minimally invasive aortic valve implantation; the initial 50 patients.

Authors:  Thomas Walther; Volkmar Falk; Jörg Kempfert; Michael A Borger; Jens Fassl; Michael W A Chu; Gerhard Schuler; Friedrich W Mohr
Journal:  Eur J Cardiothorac Surg       Date:  2008-02-21       Impact factor: 4.191

4.  Clinical results of Hancock II versus Hancock Standard at long-term follow-up.

Authors:  Carlo Valfrè; Giulio Rizzoli; Claudio Zussa; Paolo Ius; Elvio Polesel; Salvatore Mirone; Tomaso Bottio; Gino Gerosa
Journal:  J Thorac Cardiovasc Surg       Date:  2006-09       Impact factor: 5.209

5.  Bovine jugular vein conduit for right ventricular outflow tract reconstruction: evaluation of risk factors for mid-term outcome.

Authors:  Ardawan J Rastan; Thomas Walther; Ingo Daehnert; Jörg Hambsch; Friedrich W Mohr; Jan Janousek; Martin Kostelka
Journal:  Ann Thorac Surg       Date:  2006-10       Impact factor: 4.330

6.  Hemodynamic performance of the Medtronic Mosaic porcine bioprosthesis up to ten years.

Authors:  Friedrich-Christian Riess; Ralf Bader; Eva Cramer; Lorenz Hansen; Bèr Kleijnen; Gunther Wahl; Jürgen Wallrath; Stephan Winkel; Niels Bleese
Journal:  Ann Thorac Surg       Date:  2007-04       Impact factor: 4.330

7.  Ten-year outcome after aortic valve replacement with the freestyle stentless bioprosthesis.

Authors:  David S Bach; Neal D Kon; Jean G Dumesnil; Colleen F Sintek; Donald B Doty
Journal:  Ann Thorac Surg       Date:  2005-08       Impact factor: 4.330

8.  Small aortic annulus: the hydrodynamic performances of 5 commercially available bileaflet mechanical valves.

Authors:  Tomaso Bottio; Luca Caprili; Dino Casarotto; Gino Gerosa
Journal:  J Thorac Cardiovasc Surg       Date:  2004-09       Impact factor: 5.209

9.  Surgical aspects of endovascular retrograde implantation of the aortic CoreValve bioprosthesis in high-risk older patients with severe symptomatic aortic stenosis.

Authors:  Bertrand Marcheix; Yoan Lamarche; Colin Berry; Anita Asgar; Jean-Claude Laborde; Arsène Basmadjian; Anique Ducharme; André Denault; Raoul Bonan; Raymond Cartier
Journal:  J Thorac Cardiovasc Surg       Date:  2007-11       Impact factor: 5.209

10.  Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: device success and 30-day clinical outcome.

Authors:  Eberhard Grube; Gerhard Schuler; Lutz Buellesfeld; Ulrich Gerckens; Axel Linke; Peter Wenaweser; Barthel Sauren; Friedrich-Wilhelm Mohr; Thomas Walther; Bernfried Zickmann; Stein Iversen; Thomas Felderhoff; Raymond Cartier; Raoul Bonan
Journal:  J Am Coll Cardiol       Date:  2007-06-06       Impact factor: 24.094

View more
  3 in total

Review 1.  Journal of Artificial Organs 2010: the year in review.

Authors: 
Journal:  J Artif Organs       Date:  2011-03-16       Impact factor: 1.731

2.  In vitro hydrodynamic evaluation of a biovalve with stent (tubular leaflet type) for transcatheter pulmonary valve implantation.

Authors:  Hirohito Sumikura; Yasuhide Nakayama; Kentaro Ohnuma; Satoru Kishimoto; Yoshiaki Takewa; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2015-07-04       Impact factor: 1.731

3.  Utilization of star-shaped polymer architecture in the creation of high-density polymer brush coatings for the prevention of platelet and bacteria adhesion.

Authors:  Masayasu Totani; Tsuyoshi Ando; Kayo Terada; Takaya Terashima; Ill Yong Kim; Chikara Ohtsuki; Chuanwu Xi; Kenichi Kuroda; Masao Tanihara
Journal:  Biomater Sci       Date:  2014-09-01       Impact factor: 7.590