Literature DB >> 16479600

Influence of polyethylene creep behavior on wear in total hip arthroplasty.

Janaki R Penmetsa1, Peter J Laz, Anthony J Petrella, Paul J Rullkoetter.   

Abstract

After total hip arthroplasty (THA), polyethylene acetabular liner creep occurs quickly and serves to increases head-liner contact area and decrease contact pressures. What effect these early changes in contact mechanics will have on the wear behavior of the articulation remains unclear, and hence, selection or modification of polyethylene materials for optimal creep and wear performance is impossible. The objective of this study was to determine the influence of polyethylene creep behavior on volumetric wear and linear creep and wear penetration during simulated gait loading conditions. A finite element model of THA articulation was developed, and simultaneous numerical creep and wear simulation was performed to 10 million gait cycles with three levels of polyethylene creep behavior. Long-term volumetric wear and penetration were surprisingly unaffected by the polyethylene creep behavior due to the competing decrease in contact pressures coupled with increased contact area. In addition, variation in contact mechanics with the creep levels studied was only noteworthy in the initial postoperative period; after 1 million gait cycles, peak contact pressures and areas were within 13% regardless of the creep material behavior selected. Femoral head size had considerable impact on wear and penetration, while liner thickness primarily affected only early penetration. These results suggest that polyethylene creep behavior plays a major role in early penetration, but has little influence on the more important long-term volumetric wear. Copyright 2005 Orthopaedic Research Society.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16479600     DOI: 10.1002/jor.20042

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  7 in total

1.  Cross-shear implementation in sliding-distance-coupled finite element analysis of wear in metal-on-polyethylene total joint arthroplasty: intervertebral total disc replacement as an illustrative application.

Authors:  Curtis M Goreham-Voss; Philip J Hyde; Richard M Hall; John Fisher; Thomas D Brown
Journal:  J Biomech       Date:  2010-06-18       Impact factor: 2.712

2.  Results of Primary Total Hip Arthroplasty Using 36 mm Femoral Heads on 1st Generation Highly Cross Linked Polyethylene in Patients 50 Years and Less with Minimum Five Year Follow-up.

Authors:  Won-Kee Choi; Myung-Rae Cho; Hee-Soo Kim; Jun-Ho Nam; Seung-Bum Chae
Journal:  Hip Pelvis       Date:  2016-06-30

3.  Wear Rates of XLPE Nearly 50% Lower Than Previously Thought After Adjusting for Initial Creep: An RCT Comparing 4 Bearing Combinations.

Authors:  Amir Khoshbin; James Wu; Sarah Ward; Luana T Melo; Emil H Schemitsch; James P Waddell; Amit Atrey
Journal:  JB JS Open Access       Date:  2020-06-05

4.  Retroacetabular osteolytic lesions behind well-fixed prosthetic cups: pilot study of bearings-retaining surgery.

Authors:  Luca Pierannunzii; Florian Fischer; Marco d'Imporzano
Journal:  J Orthop Traumatol       Date:  2008-10-25

5.  Contact mechanics of modular metal-on-polyethylene total hip replacement under adverse edge loading conditions.

Authors:  Xijin Hua; Junyan Li; Ling Wang; Zhongmin Jin; Ruth Wilcox; John Fisher
Journal:  J Biomech       Date:  2014-09-01       Impact factor: 2.712

6.  The effect of insert conformity and material on total knee replacement wear.

Authors:  Abdellatif Abdelgaied; Claire L Brockett; Feng Liu; Louise M Jennings; Zhongmin Jin; John Fisher
Journal:  Proc Inst Mech Eng H       Date:  2013-12-02       Impact factor: 1.617

7.  Effects of Surface Modification and Bulk Geometry on the Biotribological Behavior of Cross-Linked Polyethylene: Wear Testing and Finite Element Analysis.

Authors:  Kenichi Watanabe; Masayuki Kyomoto; Kenichi Saiga; Shuji Taketomi; Hiroshi Inui; Yuho Kadono; Yoshio Takatori; Sakae Tanaka; Kazuhiko Ishihara; Toru Moro
Journal:  Biomed Res Int       Date:  2015-10-25       Impact factor: 3.411

  7 in total