Literature DB >> 16468449

Generation and visualization of four-dimensional MR angiography data using an undersampled 3-D projection trajectory.

Jing Liu1, Michael J Redmond, Ethan K Brodsky, Andrew L Alexander, Aiming Lu, Francis J Thornton, Michael J Schulte, Thomas M Grist, James G Pipe, Walter F Block.   

Abstract

Time-resolved contrast-enhanced magnetic resonance (MR) angiography (CE-MRA) has gained in popularity relative to X-ray Digital Subtraction Angiography because it provides three-dimensional (3-D) spatial resolution and it is less invasive. We have previously presented methods that improve temporal resolution in CE-MRA while providing high spatial resolution by employing an undersampled 3-D projection (3D PR) trajectory. The increased coverage and isotropic resolution of the 3D PR acquisition simplify visualization of the vasculature from any perspective. We present a new algorithm to develop a set of time-resolved 3-D image volumes by preferentially weighting the 3D PR data according to its acquisition time. An iterative algorithm computes a series of density compensation functions for a regridding reconstruction, one for each time frame, that exploit the variable sampling density in 3D PR. The iterative weighting procedure simplifies the calculation of appropriate density compensation for arbitrary sampling patterns, which improve sampling efficiency and, thus, signal-to-noise ratio and contrast-to-noise ratio, since it is does not require a closed-form calculation based on geometry. Current medical workstations can display these large four-dimensional studies, however, interactive cine animation of the data is only possible at significantly degraded resolution. Therefore, we also present a method for interactive visualization using powerful graphics cards and distributed processing. Results from volunteer and patient studies demonstrate the advantages of dynamic imaging with high spatial resolution.

Entities:  

Mesh:

Year:  2006        PMID: 16468449     DOI: 10.1109/TMI.2005.861706

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  34 in total

1.  Four-dimensional phase contrast MRI with accelerated dual velocity encoding.

Authors:  Elizabeth J Nett; Kevin M Johnson; Alex Frydrychowicz; Alejandro Munoz Del Rio; Eric Schrauben; Christopher J Francois; Oliver Wieben
Journal:  J Magn Reson Imaging       Date:  2012-01-26       Impact factor: 4.813

2.  Four-dimensional velocity mapping of the hepatic and splanchnic vasculature with radial sampling at 3 tesla: a feasibility study in portal hypertension.

Authors:  A Frydrychowicz; B R Landgraf; E Niespodzany; R W Verma; A Roldán-Alzate; K M Johnson; O Wieben; S B Reeder
Journal:  J Magn Reson Imaging       Date:  2011-07-12       Impact factor: 4.813

3.  Sparse and optimal acquisition design for diffusion MRI and beyond.

Authors:  Cheng Guan Koay; Evren Ozarslan; Kevin M Johnson; M Elizabeth Meyerand
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

4.  Regional hypoxic cerebral vasodilation facilitated by diameter changes primarily in anterior versus posterior circulation.

Authors:  J Mikhail Kellawan; John W Harrell; Alejandro Roldan-Alzate; Oliver Wieben; William G Schrage
Journal:  J Cereb Blood Flow Metab       Date:  2016-01-01       Impact factor: 6.200

5.  Respiratory and cardiac self-gated free-breathing cardiac CINE imaging with multiecho 3D hybrid radial SSFP acquisition.

Authors:  Jing Liu; Pascal Spincemaille; Noel C F Codella; Thanh D Nguyen; Martin R Prince; Yi Wang
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

6.  Fast, free-breathing, in vivo fetal imaging using time-resolved 3D MRI technique: preliminary results.

Authors:  Jing Liu; Orit A Glenn; Duan Xu
Journal:  Quant Imaging Med Surg       Date:  2014-04

7.  Insulin resistance is associated with lower arterial blood flow and reduced cortical perfusion in cognitively asymptomatic middle-aged adults.

Authors:  Siobhan M Hoscheidt; J Mikhail Kellawan; Sara E Berman; Leonardo A Rivera-Rivera; Rachel A Krause; Jennifer M Oh; Michal S Beeri; Howard A Rowley; Oliver Wieben; Cynthia M Carlsson; Sanjay Asthana; Sterling C Johnson; William G Schrage; Barbara B Bendlin
Journal:  J Cereb Blood Flow Metab       Date:  2016-01-01       Impact factor: 6.200

8.  Measuring pulsatile flow in cerebral arteries using 4D phase-contrast MR imaging.

Authors:  A Wåhlin; K Ambarki; R Birgander; O Wieben; K M Johnson; J Malm; A Eklund
Journal:  AJNR Am J Neuroradiol       Date:  2013-03-14       Impact factor: 3.825

9.  Measurements of wall shear stress and aortic pulse wave velocity in swine with familial hypercholesterolemia.

Authors:  Andrew L Wentland; Oliver Wieben; Dhanansayan Shanmuganayagam; Christian G Krueger; Jennifer J Meudt; Daniel Consigny; Leonardo Rivera; Patrick E McBride; Jess D Reed; Thomas M Grist
Journal:  J Magn Reson Imaging       Date:  2014-06-25       Impact factor: 4.813

10.  3D diffusion tensor MRI with isotropic resolution using a steady-state radial acquisition.

Authors:  Youngkyoo Jung; Alexey A Samsonov; Walter F Block; Mariana Lazar; Aiming Lu; Jing Liu; Andrew L Alexander
Journal:  J Magn Reson Imaging       Date:  2009-05       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.