Literature DB >> 16467584

Evaluation of accelerated iterative x-ray CT image reconstruction using floating point graphics hardware.

J S Kole1, F J Beekman.   

Abstract

Statistical reconstruction methods offer possibilities to improve image quality as compared with analytical methods, but current reconstruction times prohibit routine application in clinical and micro-CT. In particular, for cone-beam x-ray CT, the use of graphics hardware has been proposed to accelerate the forward and back-projection operations, in order to reduce reconstruction times. In the past, wide application of this texture hardware mapping approach was hampered owing to limited intrinsic accuracy. Recently, however, floating point precision has become available in the latest generation commodity graphics cards. In this paper, we utilize this feature to construct a graphics hardware accelerated version of the ordered subset convex reconstruction algorithm. The aims of this paper are (i) to study the impact of using graphics hardware acceleration for statistical reconstruction on the reconstructed image accuracy and (ii) to measure the speed increase one can obtain by using graphics hardware acceleration. We compare the unaccelerated algorithm with the graphics hardware accelerated version, and for the latter we consider two different interpolation techniques. A simulation study of a micro-CT scanner with a mathematical phantom shows that at almost preserved reconstructed image accuracy, speed-ups of a factor 40 to 222 can be achieved, compared with the unaccelerated algorithm, and depending on the phantom and detector sizes. Reconstruction from physical phantom data reconfirms the usability of the accelerated algorithm for practical cases.

Mesh:

Year:  2006        PMID: 16467584     DOI: 10.1088/0031-9155/51/4/008

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

1.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

2.  Scatter correction for cone-beam CT in radiation therapy.

Authors:  Lei Zhu; Yaoqin Xie; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

3.  Temporal resolution improvement using PICCS in MDCT cardiac imaging.

Authors:  Guang-Hong Chen; Jie Tang; Jiang Hsieh
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

4.  Accelerated statistical reconstruction for C-arm cone-beam CT using Nesterov's method.

Authors:  Adam S Wang; J Webster Stayman; Yoshito Otake; Sebastian Vogt; Gerhard Kleinszig; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

Review 5.  Applications of nonlocal means algorithm in low-dose X-ray CT image processing and reconstruction: A review.

Authors:  Hao Zhang; Dong Zeng; Hua Zhang; Jing Wang; Zhengrong Liang; Jianhua Ma
Journal:  Med Phys       Date:  2017-03       Impact factor: 4.071

6.  Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization.

Authors:  Emil Y Sidky; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2008-08-13       Impact factor: 3.609

7.  On the efficiency of iterative ordered subset reconstruction algorithms for acceleration on GPUs.

Authors:  Fang Xu; Wei Xu; Mel Jones; Bettina Keszthelyi; John Sedat; David Agard; Klaus Mueller
Journal:  Comput Methods Programs Biomed       Date:  2009-10-21       Impact factor: 5.428

8.  Fast, accurate and shift-varying line projections for iterative reconstruction using the GPU.

Authors:  Guillem Pratx; Garry Chinn; Peter D Olcott; Craig S Levin
Journal:  IEEE Trans Med Imaging       Date:  2009-03       Impact factor: 10.048

Review 9.  In vivo small-animal imaging using micro-CT and digital subtraction angiography.

Authors:  C T Badea; M Drangova; D W Holdsworth; G A Johnson
Journal:  Phys Med Biol       Date:  2008-08-29       Impact factor: 3.609

10.  High-performance iterative electron tomography reconstruction with long-object compensation using graphics processing units (GPUs).

Authors:  Wei Xu; Fang Xu; Mel Jones; Bettina Keszthelyi; John Sedat; David Agard; Klaus Mueller
Journal:  J Struct Biol       Date:  2010-04-04       Impact factor: 2.867

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.