A new method of noninvasive brain-edema monitoring in stroke: cerebral electrical impedance measurement.

LiXu Liu1, WeiWei Dong, XunMing Ji, LiHua Chen, Ling Chen, Wei He, JianPing Jia.   

Abstract

OBJECTIVE: To explore the primary regularity of cerebral electrical impedance (CEI) change in healthy people, patients with intracerebral hemorrhage (ICH) and patients with cerebral infarction (CI).
METHODS: CEI of 200 healthy volunteers, 78 patients with ICH and 51 patients with CI were measured by noninvasive brain-edema monitor. The results of perturbative index (PI) converted from CEI were compared with the volumes of infarction, hematoma and surrounding edema, which were calculated by image analysing system according to MRI or CT scan.
RESULTS: (1) In the normal groups, PI in the left and right sides of cerebral hemispheres was respectively 7.98 +/- 0.95 and 8.02 +/- 0.71, and there was no significant difference between the two sides (p>0.05). (2) In the patients with ICH, PI of the hematoma side initially was lower than the other side, but then increased and finally exceeded that of the other side. The average transitional time was 19.67 +/- 11.52 hours. Perturbative index of the hematoma side after the transitional time was much higher than before the transitional time in the same patients (7.79 +/- 0.75 versus 7.09 +/- 0.72) (p<0.001). The volumes of peri-hematoma edema were also significantly larger after the transitional time than before (24.32 +/- 12.86 versus 13.33 +/- 6.12) (p<0.05). There was a positive correlation between the PI of hematoma side and the volumes of peri-hematoma edema (p<0.01). (3) In the patients with arterothrombotic cerebral infarction, PI in the infarct side was higher than that in the opposite side 3-5 days after onset (8.93 +/- 1.89 versus 8.58 +/- 1.61) (p<0.001), and PI of the infarct side had a positive correlation with the volume of infarction (p<0.001). (4) The sensitivity of PI was high when the volumes of lesions were >20 ml or the position of them were located in the basal ganglia, but was low when the volumes were <20 ml or the position near the midline.
CONCLUSION: CEI may be a useful parameter for noninvasively monitoring the change of brain edema and hematoma in stroke at bedside. It could be a good complement to CT and MRI.

Entities:  

Mesh:

Year:  2006        PMID: 16464360     DOI: 10.1179/016164106X91843

Source DB:  PubMed          Journal:  Neurol Res        ISSN: 0161-6412            Impact factor:   2.448


  11 in total

Review 1.  Noninvasive Neuromonitoring: Current Utility in Subarachnoid Hemorrhage, Traumatic Brain Injury, and Stroke.

Authors:  Luisa Vinciguerra; Julian Bösel
Journal:  Neurocrit Care       Date:  2017-08       Impact factor: 3.210

2.  A method for unwrapping highly wrapped multi-echo phase images at very high field: UMPIRE.

Authors:  Simon Robinson; Horst Schödl; Siegfried Trattnig
Journal:  Magn Reson Med       Date:  2013-07-30       Impact factor: 4.668

3.  Novel Electrode Placement in Electrical Bioimpedance-Based Stroke Detection: Effects on Current Penetration and Injury Characterization in a Finite Element Model.

Authors:  Theodore S Bronk; Alicia C Everitt; Ethan K Murphy; Ryan J Halter
Journal:  IEEE Trans Biomed Eng       Date:  2022-04-21       Impact factor: 4.756

4.  Regional differences in cerebral edema after traumatic brain injury identified by impedance analysis.

Authors:  Matthew T Harting; Carter T Smith; Ravi S Radhakrishnan; Kevin R Aroom; Pramod K Dash; Brijesh Gill; Charles S Cox
Journal:  J Surg Res       Date:  2008-11-27       Impact factor: 2.192

5.  Simultaneous imaging of in vivo conductivity and susceptibility.

Authors:  Dong-Hyun Kim; Narae Choi; Sung-Min Gho; Jaewook Shin; Chunlei Liu
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

6.  Twenty-Four-Hour Real-Time Continuous Monitoring of Cerebral Edema in Rabbits Based on a Noninvasive and Noncontact System of Magnetic Induction.

Authors:  Gen Li; Ke Ma; Jian Sun; Gui Jin; Mingxin Qin; Hua Feng
Journal:  Sensors (Basel)       Date:  2017-03-08       Impact factor: 3.576

7.  Improved Sensing Pulses for Increased Human Head Depth Measurement Sensitivity With Electrical Impedance Spectroscopy.

Authors:  Giorgio Bonmassar; Michael H Lev
Journal:  IEEE Trans Biomed Eng       Date:  2013-09-10       Impact factor: 4.538

8.  Single acquisition electrical property mapping based on relative coil sensitivities: A proof-of-concept demonstration.

Authors:  José P Marques; Daniel K Sodickson; Ozlem Ipek; Christopher M Collins; Rolf Gruetter
Journal:  Magn Reson Med       Date:  2014-08-05       Impact factor: 4.668

9.  Stroke damage detection using classification trees on electrical bioimpedance cerebral spectroscopy measurements.

Authors:  Seyed Reza Atefi; Fernando Seoane; Thorleif Thorlin; Kaj Lindecrantz
Journal:  Sensors (Basel)       Date:  2013-08-07       Impact factor: 3.576

10.  Exploratory study on the methodology of fast imaging of unilateral stroke lesions by electrical impedance asymmetry in human heads.

Authors:  Jieshi Ma; Canhua Xu; Meng Dai; Fusheng You; Xuetao Shi; Xiuzhen Dong; Feng Fu
Journal:  ScientificWorldJournal       Date:  2014-05-29