Reproducibility of liver position using active breathing coordinator for liver cancer radiotherapy.

Cynthia Eccles1, Kristy K Brock, Jean-Pierre Bissonnette, Maria Hawkins, Laura A Dawson.   

Abstract

PURPOSE: To measure the intrabreath-hold liver motion and the intrafraction and interfraction reproducibility of liver position relative to vertebral bodies using an active breathing coordinator (ABC) in patients with unresectable liver cancer treated with hypofractionated stereotactic body radiation therapy (SBRT).
METHODS: Tolerability of ABC and organ motion during ABC was assessed using kV fluoroscopy in 34 patients. For patients treated with ABC, repeat breath-hold CT scans in the ABC breath-hold position were acquired at simulation to estimate the volumetric intrafraction reproducibility of the liver relative to the vertebral bodies. In addition, preceding each radiation therapy fraction, with the liver immobilized using ABC, repeat anteroposterior (AP) megavoltage verification images were obtained. Off-line alignments were completed to determine intrafraction reproducibility (from repeat images obtained before one treatment) and interfraction reproducibility (from comparisons of the final image for each fraction with the AP) of diaphragm position relative to vertebral bodies. For each image set, the vertebral bodies were aligned, and the resultant craniocaudal (CC) offset in diaphragm position was measured. Liver position during ABC was also evaluated from kV fluoroscopy acquired at the time of simulation, kV fluoroscopy at the time of treatment, and from MV beam's-eye view movie loops acquired during treatment.
RESULTS: Twenty-one of 34 patients were screened to be suitable for ABC. The average free breathing range of these patients was 13 mm (range, 5-1 mm). Fluoroscopy revealed that the average maximal diaphragm motion during ABC breath-hold was 1.4 mm (range, 0-3.4 mm). The MV treatment movie loops confirmed diaphragm stability during treatment. For a measure of intrafraction reproducibility, an analysis of 36 repeat ABC computed tomography (CT) scans in 14 patients was conducted. The average mean difference in the liver surface position was -0.9 mm, -0.5 mm, and 0.2 mm in the CC, AP, and medial-lateral (ML) directions, with a standard deviation of 1.5 mm, 1.5 mm, and 1.5 mm, respectively. Ninety-five percent of the liver surface had an absolute differences in position between repeat ABC CT scans of less than 4.1 mm, 3.3 mm, and 3.3 mm in the CC, AP, and ML directions, respectively. Analysis of 257 MV AP images from patients treated using ABC revealed an average intrafraction CC reproducibility (sigma) of diaphragm relative to vertebral bodies of 1.5 mm (range, 0.6-3.9 mm). The average interfraction CC reproducibility (sigma) was 3.4 mm (range, 1.5-7.9 mm), indicating less day-to-day reproducibility of diaphragm position relative to vertebral bodies. The average absolute intra and interfraction CC offset in diaphragm position relative to vertebral bodies was 1.7 and 3.7 mm, respectively, with 86% of intrafraction and 54% of interfraction absolute offsets 3.0 mm or less.
CONCLUSIONS: Intrafraction reproducibility of liver position using ABC is good in the majority of screened patients. However, interfraction reproducibility is worse, suggesting a need for image guidance.

Entities:  

Mesh:

Year:  2006        PMID: 16458774     DOI: 10.1016/j.ijrobp.2005.05.066

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  45 in total

Review 1.  Imaging and image-guided radiation therapy in liver cancer.

Authors:  Kristy K Brock
Journal:  Semin Radiat Oncol       Date:  2011-10       Impact factor: 5.934

2.  [Image-guided radiation therapy].

Authors:  J Boda-Heggemann; M Guckenberger; U Ganswindt; C Belka; H Wertz; M Blessing; F Wenz; M Fuss; F Lohr
Journal:  Radiologe       Date:  2012-03       Impact factor: 0.635

3.  Digital tomosynthesis for respiratory gated liver treatment: clinical feasibility for daily image guidance.

Authors:  Q Jackie Wu; Jeffrey Meyer; Jessica Fuller; Devon Godfrey; Zhiheng Wang; Junan Zhang; Fang-Fang Yin
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-06-18       Impact factor: 7.038

4.  RapidArc combined with the active breathing coordinator provides an effective and accurate approach for the radiotherapy of hepatocellular carcinoma.

Authors:  G Z Gong; Y Yin; L G Xing; Y J Guo; T Liu; J Chen; J Lu; C Ma; T Sun; T Bai; G Zhang; R Wang
Journal:  Strahlenther Onkol       Date:  2012-02-08       Impact factor: 3.621

5.  Multiple Breath-hold Volumetric Modulated Arc Therapy Under Fluoroscopic Image Guidance with an Implanted Fiducial Marker: An Advanced Technique.

Authors:  Tsuyoshi Takanaka; Yoko Taima; Yasushi Horichi; Yasuhiro Kawamori; Koji Nobata; Kiyohide Kitagawa; Azusa Norishima; Kento Koshikawa; Tatsuya Mito; Satoshi Yoshida; Tetsuya Kawanaka; Katsuaki Matsutani; Masahiro Kawahara
Journal:  Cureus       Date:  2018-04-18

Review 6.  kV cone-beam CT-based IGRT: a clinical review.

Authors:  Judit Boda-Heggemann; Frank Lohr; Frederik Wenz; Michael Flentje; Matthias Guckenberger
Journal:  Strahlenther Onkol       Date:  2011-04-26       Impact factor: 3.621

7.  Evaluation of reproducibility of tumor repositioning during multiple breathing cycles for liver stereotactic body radiotherapy treatment.

Authors:  Ludovic Bedos; Olivier Riou; Norbert Aillères; Antoine Braccini; Jessica Molinier; Carmen Llacer Moscardo; David Azria; Pascal Fenoglietto
Journal:  Rep Pract Oncol Radiother       Date:  2016-11-12

Review 8.  Solutions that enable ablative radiotherapy for large liver tumors: Fractionated dose painting, simultaneous integrated protection, motion management, and computed tomography image guidance.

Authors:  Christopher H Crane; Eugene J Koay
Journal:  Cancer       Date:  2016-03-07       Impact factor: 6.860

9.  Reproducibility of diaphragm position assessed with a voluntary breath-holding device.

Authors:  Shigeyuki Takamatsu; Tsuyoshi Takanaka; Tomoyasu Kumano; Eiichi Mizuno; Satoshi Shibata; Shizuko Ohashi; Yuichi Kurata; Shinichi Ueda; Naoki Hori; Saori Shouji; Kimiya Noto; Hironori Kojima; Osamu Matsui
Journal:  Jpn J Radiol       Date:  2013-03-23       Impact factor: 2.374

10.  Short-term displacement and reproducibility of the breast and nodal targets under active breathing control.

Authors:  Jean M Moran; James M Balter; Merav A Ben-David; Robin B Marsh; Marcel Van Herk; Lori J Pierce
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-06-01       Impact factor: 7.038

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.