Measurements of objective and subjective fixation disparity with and without a central fusion stimulus.

Rune L Brautaset1, J Adrian M Jennings.   

Abstract

BACKGROUND: Fixation disparity is the condition in which the images of a binocularly fixated object are not imaged on exactly corresponding retinal points, but are still within Panum's fusional areas. Measurements of objective and subjective fixation disparity have indicated that subjective fixation disparity does not indicate the true eye position. However, the effect of the foveal fusional lock (FFL) on the relationship between objective and subjective fixation disparity is still not clear. MATERIAL/
METHODS: This relationship was investigated in five subjects. The objective measurements were made using scleral search coils, and at the same time the Sheedy distance disparometer indicated the subjective fixation disparity. Measurements were obtained both with and without an FFL.
RESULTS: It was found that without an FFL there was a significant difference (p<0.05) between subjective and objective fixation disparity, whereas when an FFL was added, the difference was no longer significant. Additionally, the absolute sizes of both SFD and OFD were found to be significantly smaller with the FFL.
CONCLUSIONS: These results indicate that the presence of an FFL makes subjective fixation disparity a more accurate indicator of the objective eye position. An instrument with an FFL should therefore be used clinically. The difference between objective and subjective fixation disparity presumably indicates a change in correspondence.

Entities:  

Mesh:

Year:  2006        PMID: 16449958

Source DB:  PubMed          Journal:  Med Sci Monit        ISSN: 1234-1010


  4 in total

1.  Effects of Prism Eyeglasses on Objective and Subjective Fixation Disparity.

Authors:  Volkhard Schroth; Roland Joos; Wolfgang Jaschinski
Journal:  PLoS One       Date:  2015-10-02       Impact factor: 3.240

2.  Individual objective versus subjective fixation disparity as a function of forced vergence.

Authors:  Wolfgang Jaschinski
Journal:  PLoS One       Date:  2018-07-06       Impact factor: 3.240

3.  Effects of aligning prisms on the objective and subjective fixation disparity in far distance.

Authors:  Volkhard Schroth; Roland Joos; Ewald Alshuth; Wolfgang Jaschinski
Journal:  J Eye Mov Res       Date:  2019-12-11       Impact factor: 0.957

4.  Does an iPad fixation disparity test give equivalent results to the Mallett near fixation disparity test?

Authors:  Ketan R Parmar; Christine Dickinson; Bruce J W Evans
Journal:  J Optom       Date:  2019-09-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.