Literature DB >> 16425828

Direct neural sensory feedback and control of a prosthetic arm.

Gurpreet Singh Dhillon1, Kenneth W Horch.   

Abstract

Evidence indicates that user acceptance of modern artificial limbs by amputees would be significantly enhanced by a system that provides appropriate, graded, distally referred sensations of touch and joint movement, and that the functionality of limb prostheses would be improved by a more natural control mechanism. We have recently demonstrated that it is possible to implant electrodes within individual fascicles of peripheral nerve stumps in amputees, that stimulation through these electrodes can produce graded, discrete sensations of touch or movement referred to the amputee's phantom hand, and that recordings of motor neuron activity associated with attempted movements of the phantom limb through these electrodes can be used as graded control signals. We report here that this approach allows amputees to both judge and set grip force and joint position in an artificial arm, in the absence of visual input, thus providing a substrate for better integration of the artificial limb into the amputee's body image. We believe this to be the first demonstration of direct neural feedback from and direct neural control of an artificial arm in amputees.

Mesh:

Year:  2005        PMID: 16425828     DOI: 10.1109/TNSRE.2005.856072

Source DB:  PubMed          Journal:  IEEE Trans Neural Syst Rehabil Eng        ISSN: 1534-4320            Impact factor:   3.802


  116 in total

1.  Sensing with the motor cortex.

Authors:  Nicholas G Hatsopoulos; Aaron J Suminski
Journal:  Neuron       Date:  2011-11-03       Impact factor: 17.173

2.  A hybrid approach for the control of axonal outgrowth: preliminary simulation results.

Authors:  Gianni Ciofani; Pier Nicola Sergi; Jacopo Carpaneto; Silvestro Micera
Journal:  Med Biol Eng Comput       Date:  2010-10-06       Impact factor: 2.602

Review 3.  Neural interfaces for somatosensory feedback: bringing life to a prosthesis.

Authors:  Dustin J Tyler
Journal:  Curr Opin Neurol       Date:  2015-12       Impact factor: 5.710

4.  Sensory feedback by peripheral nerve stimulation improves task performance in individuals with upper limb loss using a myoelectric prosthesis.

Authors:  Matthew Schiefer; Daniel Tan; Steven M Sidek; Dustin J Tyler
Journal:  J Neural Eng       Date:  2015-12-08       Impact factor: 5.379

Review 5.  Implantable neurotechnologies: bidirectional neural interfaces--applications and VLSI circuit implementations.

Authors:  Elliot Greenwald; Matthew R Masters; Nitish V Thakor
Journal:  Med Biol Eng Comput       Date:  2016-01-11       Impact factor: 2.602

6.  Implantation mechanics of tungsten microneedles into peripheral nerve trunks.

Authors:  Ken Yoshida; Ina Lewinsky; Mogens Nielsen; Mads Hylleberg
Journal:  Med Biol Eng Comput       Date:  2007-03-01       Impact factor: 2.602

7.  Illusory movement perception improves motor control for prosthetic hands.

Authors:  Paul D Marasco; Jacqueline S Hebert; Jon W Sensinger; Courtney E Shell; Jonathon S Schofield; Zachary C Thumser; Raviraj Nataraj; Dylan T Beckler; Michael R Dawson; Dan H Blustein; Satinder Gill; Brett D Mensh; Rafael Granja-Vazquez; Madeline D Newcomb; Jason P Carey; Beth M Orzell
Journal:  Sci Transl Med       Date:  2018-03-14       Impact factor: 17.956

8.  High-performance neuroprosthetic control by an individual with tetraplegia.

Authors:  Jennifer L Collinger; Brian Wodlinger; John E Downey; Wei Wang; Elizabeth C Tyler-Kabara; Douglas J Weber; Angus J C McMorland; Meel Velliste; Michael L Boninger; Andrew B Schwartz
Journal:  Lancet       Date:  2012-12-17       Impact factor: 79.321

Review 9.  Neural interface technology for rehabilitation: exploiting and promoting neuroplasticity.

Authors:  Wei Wang; Jennifer L Collinger; Monica A Perez; Elizabeth C Tyler-Kabara; Leonardo G Cohen; Niels Birbaumer; Steven W Brose; Andrew B Schwartz; Michael L Boninger; Douglas J Weber
Journal:  Phys Med Rehabil Clin N Am       Date:  2010-02       Impact factor: 1.784

10.  Statistical analysis and modeling of variance in the SA-I mechanoreceptor response to sustained indentation.

Authors:  Daine R Lesniak; Scott A Wellnitz; Gregory J Gerling; Ellen A Lumpkin
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.