Literature DB >> 17333101

Implantation mechanics of tungsten microneedles into peripheral nerve trunks.

Ken Yoshida1, Ina Lewinsky, Mogens Nielsen, Mads Hylleberg.   

Abstract

50 microm tungsten microneedles have been used as a means to introduce longitudinal intra-fascicular electrodes (LIFE) into small peripheral nerve fascicles. However, recent attempts to implant LIFEs into larger, human sized nerves with the same needles resulted in buckling failure of the introducer needle. In the present study, the implantation mechanics (penetration forces and penetration dimple depth) of electrosharpened tungsten microneedles ranging in diameters from 50 to 200 microm into freshly excised porcine peripheral nerve trunks between 3 and 5 mm in thickness was characterized to understand the implantation mechanics and to find the minimum needle diameter that would result in successful penetration. The implant success rate was found to be highest with needles having diameters between 80 and 120 microm. The force of successful penetration ranged from 7.2 +/- 0.6 to 71.8 +/- 19.5 mN, and increased monotonically with needle diameter. It also had a tendency to increase with increasing tip angles. The dimple depth for successful penetrations varied between 1 and 1.5 mm, and also tended to increase with increasing tip angles, although it was generally not affected by increased needle diameter. Only the smallest penetration dimple depth was found to be different from the others and was associated with the smallest diameter needle (50 microm). Analysis based on the critical buckling force and the measured implantation forces indicated a 15 mm long needle of 80 microm diameter would be necessary and sufficient to penetrate medium to large sized nerves.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17333101     DOI: 10.1007/s11517-007-0175-0

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  13 in total

1.  Residual function in peripheral nerve stumps of amputees: implications for neural control of artificial limbs.

Authors:  Gurpreet S Dhillon; Stephen M Lawrence; Douglas T Hutchinson; Kenneth W Horch
Journal:  J Hand Surg Am       Date:  2004-07       Impact factor: 2.230

2.  Chronically implanted intrafascicular recording electrodes.

Authors:  T Lefurge; E Goodall; K Horch; L Stensaas; A Schoenberg
Journal:  Ann Biomed Eng       Date:  1991       Impact factor: 3.934

3.  Assessment of biocompatibility of chronically implanted polyimide and platinum intrafascicular electrodes.

Authors:  Natalia Lago; Ken Yoshida; Klaus P Koch; Xavier Navarro
Journal:  IEEE Trans Biomed Eng       Date:  2007-02       Impact factor: 4.538

4.  Characterization of signals and noise rejection with bipolar longitudinal intrafascicular electrodes.

Authors:  K Yoshida; R B Stein
Journal:  IEEE Trans Biomed Eng       Date:  1999-02       Impact factor: 4.538

5.  In-vivo implant mechanics of flexible, silicon-based ACREO microelectrode arrays in rat cerebral cortex.

Authors:  Winnie Jensen; Ken Yoshida; Ulrich G Hofmann
Journal:  IEEE Trans Biomed Eng       Date:  2006-05       Impact factor: 4.538

6.  De- and regeneration of axons after minor lesions in the rat sciatic nerve. Effects of microneurography electrode penetrations.

Authors:  K Fried; J Frisén; M Mozart
Journal:  Pain       Date:  1989-01       Impact factor: 6.961

7.  Activity from skin mechanoreceptors recorded percutaneously in awake human subjects.

Authors:  A B Vallbo; K E Hagbarth
Journal:  Exp Neurol       Date:  1968-07       Impact factor: 5.330

8.  Effects of short-term training on sensory and motor function in severed nerves of long-term human amputees.

Authors:  G S Dhillon; T B Krüger; J S Sandhu; K W Horch
Journal:  J Neurophysiol       Date:  2005-05       Impact factor: 2.714

9.  Hyperexcitable polymodal and insensitive nociceptors in painful human neuropathy.

Authors:  José L Ochoa; Mario Campero; Jordi Serra; Hugh Bostock
Journal:  Muscle Nerve       Date:  2005-10       Impact factor: 3.217

10.  Microelectrode recordings from transected nerves in amputees with phantom limb pain.

Authors:  B Nyström; K E Hagbarth
Journal:  Neurosci Lett       Date:  1981-12-11       Impact factor: 3.046

View more
  5 in total

1.  Fast in silico assessment of physical stress for peripheral nerves.

Authors:  Elisabetta Giannessi; Maria Rita Stornelli; Pier Nicola Sergi
Journal:  Med Biol Eng Comput       Date:  2018-02-12       Impact factor: 2.602

Review 2.  Needle-tissue interactive mechanism and steering control in image-guided robot-assisted minimally invasive surgery: a review.

Authors:  Pan Li; Zhiyong Yang; Shan Jiang
Journal:  Med Biol Eng Comput       Date:  2018-04-21       Impact factor: 2.602

Review 3.  Micro Electromechanical Systems (MEMS) Based Microfluidic Devices for Biomedical Applications.

Authors:  Muhammad Waseem Ashraf; Shahzadi Tayyaba; Nitin Afzulpurkar
Journal:  Int J Mol Sci       Date:  2011-06-07       Impact factor: 5.923

4.  A Photolithographic Approach to Polymeric Microneedles Array Fabrication.

Authors:  Principia Dardano; Alessandro Caliò; Vincenza Di Palma; Maria Fortuna Bevilacqua; Andrea Di Matteo; Luca De Stefano
Journal:  Materials (Basel)       Date:  2015-12-11       Impact factor: 3.623

5.  A unified approach to model peripheral nerves across different animal species.

Authors:  Elisabetta Giannessi; Pier Nicola Sergi; Maria Rita Stornelli
Journal:  PeerJ       Date:  2017-11-10       Impact factor: 2.984

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.