PURPOSE: To optimize the accuracy and precision of T2 measurements using the standard Carr-Purcell-Meiboom-Gill (CPMG) sequence. T2 values obtained with this technique are normally sensitive to imperfect refocusing due to the formation of unwanted stimulated echoes. MATERIALS AND METHODS: Modifications are made to the refocusing slice selection width and the interleaving scheme. A widened refocusing slice improves the uniformity of the refocusing flip angle across the slice. A slow spin echo acquisition provided "gold standard" T2 values. Repeated T2 measurements in phantom and human studies are used to compare the accuracy and precision of the optimized and non-optimized CPMG implementations. RESULTS: The required slice thickness ratio between refocusing and excitation slice widths is found to be 3:1 for typical optimized radiofrequency pulses. T2 values obtained using this optimized implementation more closely correspond to "gold standard" values. Repeated T2 measurements indicate significantly improved correspondence between data and model. A reduction in the fitting error of approximately 70% is demonstrated for phantoms. CONCLUSION: We demonstrate that a relatively simple change to the CPMG relaxometry sequence parameters from the default setup yields significant improvements in the accuracy and precision of T2 measurements. (c) 2006 Wiley-Liss, Inc.
PURPOSE: To optimize the accuracy and precision of T2 measurements using the standard Carr-Purcell-Meiboom-Gill (CPMG) sequence. T2 values obtained with this technique are normally sensitive to imperfect refocusing due to the formation of unwanted stimulated echoes. MATERIALS AND METHODS: Modifications are made to the refocusing slice selection width and the interleaving scheme. A widened refocusing slice improves the uniformity of the refocusing flip angle across the slice. A slow spin echo acquisition provided "gold standard" T2 values. Repeated T2 measurements in phantom and human studies are used to compare the accuracy and precision of the optimized and non-optimized CPMG implementations. RESULTS: The required slice thickness ratio between refocusing and excitation slice widths is found to be 3:1 for typical optimized radiofrequency pulses. T2 values obtained using this optimized implementation more closely correspond to "gold standard" values. Repeated T2 measurements indicate significantly improved correspondence between data and model. A reduction in the fitting error of approximately 70% is demonstrated for phantoms. CONCLUSION: We demonstrate that a relatively simple change to the CPMG relaxometry sequence parameters from the default setup yields significant improvements in the accuracy and precision of T2 measurements. (c) 2006 Wiley-Liss, Inc.
Authors: Lan Lu; Bernadette Erokwu; Gregory Lee; Vikas Gulani; Mark A Griswold; Katherine M Dell; Chris A Flask Journal: Magn Reson Med Date: 2011-12-02 Impact factor: 4.668
Authors: Jens H Jensen; Haiying Tang; Christina L Tosti; Srirama V Swaminathan; Alvaro Nunez; Kristi Hultman; Kamila U Szulc; Ed X Wu; Daniel Kim; Sujit Sheth; Truman R Brown; Gary M Brittenham Journal: Magn Reson Med Date: 2010-05 Impact factor: 4.668
Authors: Daniel Kim; Jens H Jensen; Ed X Wu; Li Feng; Wing-Yan Au; Jerry S Cheung; Shau-Yin Ha; Sujit S Sheth; Gary M Brittenham Journal: NMR Biomed Date: 2010-12-28 Impact factor: 4.044
Authors: Jerry S Cheung; Enfeng Wang; XiaoAn Zhang; Emiri Mandeville; Eng H Lo; A Gregory Sorensen; Phillip Zhe Sun Journal: NMR Biomed Date: 2011-07-14 Impact factor: 4.044
Authors: Matthew Marzelli; Krisztina Fischer; Young Beom Kim; Robert V Mulkern; Seung-Schik Yoo; Hyunwook Park; Zang-Hee Cho Journal: Int J Imaging Syst Technol Date: 2008-06-13 Impact factor: 2.000
Authors: Hua Guo; Wing-Yan Au; Jerry S Cheung; Daniel Kim; Jens H Jensen; Pek-Lan Khong; Queenie Chan; Kevin C Chan; Christina Tosti; Haiying Tang; Truman R Brown; Wynnie W M Lam; Shau-Yin Ha; Gary M Brittenham; Ed X Wu Journal: J Magn Reson Imaging Date: 2009-08 Impact factor: 4.813