Literature DB >> 16416434

Optimized clinical T2 relaxometry with a standard CPMG sequence.

Gaby S Pell1, Regula S Briellmann, Anthony B Waites, David F Abbott, David P Lewis, Graeme D Jackson.   

Abstract

PURPOSE: To optimize the accuracy and precision of T2 measurements using the standard Carr-Purcell-Meiboom-Gill (CPMG) sequence. T2 values obtained with this technique are normally sensitive to imperfect refocusing due to the formation of unwanted stimulated echoes.
MATERIALS AND METHODS: Modifications are made to the refocusing slice selection width and the interleaving scheme. A widened refocusing slice improves the uniformity of the refocusing flip angle across the slice. A slow spin echo acquisition provided "gold standard" T2 values. Repeated T2 measurements in phantom and human studies are used to compare the accuracy and precision of the optimized and non-optimized CPMG implementations.
RESULTS: The required slice thickness ratio between refocusing and excitation slice widths is found to be 3:1 for typical optimized radiofrequency pulses. T2 values obtained using this optimized implementation more closely correspond to "gold standard" values. Repeated T2 measurements indicate significantly improved correspondence between data and model. A reduction in the fitting error of approximately 70% is demonstrated for phantoms.
CONCLUSION: We demonstrate that a relatively simple change to the CPMG relaxometry sequence parameters from the default setup yields significant improvements in the accuracy and precision of T2 measurements. (c) 2006 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2006        PMID: 16416434     DOI: 10.1002/jmri.20490

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  27 in total

1.  Diffusion-prepared fast imaging with steady-state free precession (DP-FISP): a rapid diffusion MRI technique at 7 T.

Authors:  Lan Lu; Bernadette Erokwu; Gregory Lee; Vikas Gulani; Mark A Griswold; Katherine M Dell; Chris A Flask
Journal:  Magn Reson Med       Date:  2011-12-02       Impact factor: 4.668

2.  Separate MRI quantification of dispersed (ferritin-like) and aggregated (hemosiderin-like) storage iron.

Authors:  Jens H Jensen; Haiying Tang; Christina L Tosti; Srirama V Swaminathan; Alvaro Nunez; Kristi Hultman; Kamila U Szulc; Ed X Wu; Daniel Kim; Sujit Sheth; Truman R Brown; Gary M Brittenham
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

3.  Rapid monitoring of iron-chelating therapy in thalassemia major by a new cardiovascular MR measure: the reduced transverse relaxation rate.

Authors:  Daniel Kim; Jens H Jensen; Ed X Wu; Li Feng; Wing-Yan Au; Jerry S Cheung; Shau-Yin Ha; Sujit S Sheth; Gary M Brittenham
Journal:  NMR Biomed       Date:  2010-12-28       Impact factor: 4.044

4.  Fast radio-frequency enforced steady state (FRESS) spin echo MRI for quantitative T2 mapping: minimizing the apparent repetition time (TR) dependence for fast T2 measurement.

Authors:  Jerry S Cheung; Enfeng Wang; XiaoAn Zhang; Emiri Mandeville; Eng H Lo; A Gregory Sorensen; Phillip Zhe Sun
Journal:  NMR Biomed       Date:  2011-07-14       Impact factor: 4.044

5.  Pattern recognition for rapid T2 mapping with stimulated echo compensation.

Authors:  Chuan Huang; Maria I Altbach; Georges El Fakhri
Journal:  Magn Reson Imaging       Date:  2014-04-24       Impact factor: 2.546

6.  Composite MR Contrast Agents for Conditional Cell-Labeling.

Authors:  Matthew Marzelli; Krisztina Fischer; Young Beom Kim; Robert V Mulkern; Seung-Schik Yoo; Hyunwook Park; Zang-Hee Cho
Journal:  Int J Imaging Syst Technol       Date:  2008-06-13       Impact factor: 2.000

7.  T2 relaxometry with indirect echo compensation from highly undersampled data.

Authors:  Chuan Huang; Ali Bilgin; Tomoe Barr; Maria I Altbach
Journal:  Magn Reson Med       Date:  2012-11-19       Impact factor: 4.668

8.  Image-guided radio-frequency gain calibration for high-field MRI.

Authors:  Elodie Breton; Kellyanne McGorty; Graham C Wiggins; Leon Axel; Daniel Kim
Journal:  NMR Biomed       Date:  2009-12-15       Impact factor: 4.044

9.  Diffusion-weighted radial fast spin-echo for high-resolution diffusion tensor imaging at 3T.

Authors:  Joelle E Sarlls; Carlo Pierpaoli
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

10.  Myocardial T2 quantitation in patients with iron overload at 3 Tesla.

Authors:  Hua Guo; Wing-Yan Au; Jerry S Cheung; Daniel Kim; Jens H Jensen; Pek-Lan Khong; Queenie Chan; Kevin C Chan; Christina Tosti; Haiying Tang; Truman R Brown; Wynnie W M Lam; Shau-Yin Ha; Gary M Brittenham; Ed X Wu
Journal:  J Magn Reson Imaging       Date:  2009-08       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.