OBJECTIVES: BpTRU (VSM MedTech Ltd, Vancouver, Canada) is an automated oscillometric device that provides serial blood pressure measurements in an office setting in the absence of a healthcare professional. We sought to determine whether the white-coat effect is reduced by a blood pressure measurement protocol using BpTRU compared with casual office measurements. Secondarily, we also sought to determine whether a blood pressure measurement protocol using BpTRU reduced white-coat hypertension compared with the casual office measurements, and reduced white-coat effect and white-coat hypertension compared with blood pressure obtained by a research nurse. METHODS: Blood pressure was measured in 107 adult hypertensive patients referred for ambulatory blood pressure monitoring using an ambulatory blood pressure monitor, a standardized protocol by a trained research nurse, and a protocol using BpTRU (five readings over 25 min, using the 5-min blood pressure measurement interval setting). Casual office blood pressure was also recorded in the family physicians' offices. Using the mean daytime ambulatory blood pressure as the reference standard, the proportion of patients with white-coat effect and white-coat hypertension were determined for measurements obtained by BpTRU, the research nurse, and the family physicians' offices. RESULTS: Casual office blood pressure measurements demonstrated a white-coat effect in 39 (36.4%) patients; seven (6.5%) patients demonstrated a white-coat effect using BpTRU (P<0.0001). White-coat hypertension was also less common using BpTRU than with the casual office readings (13 vs. 1 patient, P<0.0001). White-coat effect was also reduced with BpTRU compared with the research nurse measurements. Unfortunately, percentage agreement for the diagnosis of hypertension between the protocol using BpTRU and the reference standard was only 48%. This resulted in substantial misclassification of hypertension by the BpTRU measurement protocol. CONCLUSIONS: Although BpTRU reduces white-coat effect and white-coat hypertension, blood pressure is underestimated by the device, leading to misclassification of hypertension. BpTRU, when set at 5-min blood pressure measurement intervals, should not be used in clinical practice.
OBJECTIVES: BpTRU (VSM MedTech Ltd, Vancouver, Canada) is an automated oscillometric device that provides serial blood pressure measurements in an office setting in the absence of a healthcare professional. We sought to determine whether the white-coat effect is reduced by a blood pressure measurement protocol using BpTRU compared with casual office measurements. Secondarily, we also sought to determine whether a blood pressure measurement protocol using BpTRU reduced white-coat hypertension compared with the casual office measurements, and reduced white-coat effect and white-coat hypertension compared with blood pressure obtained by a research nurse. METHODS: Blood pressure was measured in 107 adult hypertensivepatients referred for ambulatory blood pressure monitoring using an ambulatory blood pressure monitor, a standardized protocol by a trained research nurse, and a protocol using BpTRU (five readings over 25 min, using the 5-min blood pressure measurement interval setting). Casual office blood pressure was also recorded in the family physicians' offices. Using the mean daytime ambulatory blood pressure as the reference standard, the proportion of patients with white-coat effect and white-coat hypertension were determined for measurements obtained by BpTRU, the research nurse, and the family physicians' offices. RESULTS: Casual office blood pressure measurements demonstrated a white-coat effect in 39 (36.4%) patients; seven (6.5%) patients demonstrated a white-coat effect using BpTRU (P<0.0001). White-coat hypertension was also less common using BpTRU than with the casual office readings (13 vs. 1 patient, P<0.0001). White-coat effect was also reduced with BpTRU compared with the research nurse measurements. Unfortunately, percentage agreement for the diagnosis of hypertension between the protocol using BpTRU and the reference standard was only 48%. This resulted in substantial misclassification of hypertension by the BpTRU measurement protocol. CONCLUSIONS: Although BpTRU reduces white-coat effect and white-coat hypertension, blood pressure is underestimated by the device, leading to misclassification of hypertension. BpTRU, when set at 5-min blood pressure measurement intervals, should not be used in clinical practice.
Authors: Mohammed Siddiqui; Eric K Judd; Byron C Jaeger; Hemal Bhatt; Tanja Dudenbostel; Bin Zhang; Lloyd J Edwards; Suzanne Oparil; David A Calhoun Journal: Hypertension Date: 2019-01 Impact factor: 10.190
Authors: Mohammed Siddiqui; Eric K Judd; Tanja Dudenbostel; Bin Zhang; Pankaj Gupta; Maciej Tomaszewski; Prashanth Patel; Suzanne Oparil; David A Calhoun Journal: Hypertension Date: 2019-07-22 Impact factor: 10.190
Authors: Nynke Scherpbier-de Haan; Mark van der Wel; Gijs Schoenmakers; Steve Boudewijns; Petronella Peer; Chris van Weel; Theo Thien; Carel Bakx Journal: Br J Gen Pract Date: 2011-09 Impact factor: 5.386
Authors: Kimberly C Blom; Sasha Farina; Yessica-Haydee Gomez; Norm R C Campbell; Brenda R Hemmelgarn; Lyne Cloutier; Donald W McKay; Martin Dawes; Sheldon W Tobe; Peter Bolli; Mark Gelfer; Donna McLean; Gillian Bartlett; Lawrence Joseph; Robin Featherstone; Ernesto L Schiffrin; Stella S Daskalopoulou Journal: Curr Hypertens Rep Date: 2015-04 Impact factor: 5.369