C O F Kamlin1, P G Davis, C J Morley. 1. Division of Newborn Services, Royal Women's Hospital, 132 Grattan Street, Carlton, Victoria 3053, Australia. omar.kamlin@rwh.org.au
Abstract
OBJECTIVE: To determine the accuracy of three tests used to predict successful extubation of preterm infants. STUDY DESIGN: Mechanically ventilated infants with birth weight <1250 g and considered ready for extubation were changed to endotracheal continuous positive airway pressure (ET CPAP) for three minutes. Tidal volumes, minute ventilation (V e), heart rate, and oxygen saturation were recorded before and during ET CPAP. Three tests of extubation success were evaluated: (a) expired V e during ET CPAP; (b) ratio of V e during ET CPAP to V e during mechanical ventilation (V e ratio); (c) the spontaneous breathing test (SBT)-the infant passed this test if there was no hypoxia or bradycardia during ET CPAP. The clinical team were blinded to the results, and all infants were extubated. Extubation failure was defined as reintubation within 72 hours of extubation. RESULTS: Fifty infants were studied and extubated. Eleven (22%) were reintubated. The SBT was the most accurate of the three tests, with a sensitivity of 97% and specificity of 73% and a positive and negative predictive value for extubation success of 93% and 89% respectively. CONCLUSION: The SBT used just before extubation of infants <1250 g may reduce the number of extubation failures. Further studies are required to establish whether the SBT can be used as the primary determinant of an infant's readiness for extubation.
OBJECTIVE: To determine the accuracy of three tests used to predict successful extubation of preterm infants. STUDY DESIGN: Mechanically ventilated infants with birth weight <1250 g and considered ready for extubation were changed to endotracheal continuous positive airway pressure (ET CPAP) for three minutes. Tidal volumes, minute ventilation (V e), heart rate, and oxygen saturation were recorded before and during ET CPAP. Three tests of extubation success were evaluated: (a) expired V e during ET CPAP; (b) ratio of V e during ET CPAP to V e during mechanical ventilation (V e ratio); (c) the spontaneous breathing test (SBT)-the infant passed this test if there was no hypoxia or bradycardia during ET CPAP. The clinical team were blinded to the results, and all infants were extubated. Extubation failure was defined as reintubation within 72 hours of extubation. RESULTS: Fifty infants were studied and extubated. Eleven (22%) were reintubated. The SBT was the most accurate of the three tests, with a sensitivity of 97% and specificity of 73% and a positive and negative predictive value for extubation success of 93% and 89% respectively. CONCLUSION: The SBT used just before extubation of infants <1250 g may reduce the number of extubation failures. Further studies are required to establish whether the SBT can be used as the primary determinant of an infant's readiness for extubation.
Authors: Beatrice M Stefanescu; W Paul Murphy; Brenda J Hansell; Mamta Fuloria; Timothy M Morgan; Judy L Aschner Journal: Pediatrics Date: 2003-11 Impact factor: 7.124
Authors: L Dupree Hatch; Peter H Grubb; Melinda H Markham; Theresa A Scott; William F Walsh; James C Slaughter; Ann R Stark; E Wesley Ely Journal: Am J Perinatol Date: 2017-05-11 Impact factor: 1.862
Authors: Sanjay Chawla; Girija Natarajan; Seetha Shankaran; Benjamin Carper; Luc P Brion; Martin Keszler; Waldemar A Carlo; Namasivayam Ambalavanan; Marie G Gantz; Abhik Das; Neil Finer; Ronald N Goldberg; C Michael Cotten; Rosemary D Higgins Journal: J Pediatr Date: 2017-06-07 Impact factor: 4.406
Authors: Emma E Williams; Fahad M S Arattu Thodika; Imogen Chappelow; Nicole Chapman-Hatchett; Theodore Dassios; Anne Greenough Journal: Pediatr Res Date: 2022-05-06 Impact factor: 3.953
Authors: Joke M Wielenga; Agnes van den Hoogen; Henriette A van Zanten; Onno Helder; Bas Bol; Bronagh Blackwood Journal: Cochrane Database Syst Rev Date: 2016-03-21
Authors: Wissam Shalish; Lara J Kanbar; Smita Rao; Carlos A Robles-Rubio; Lajos Kovacs; Sanjay Chawla; Martin Keszler; Doina Precup; Karen Brown; Robert E Kearney; Guilherme M Sant'Anna Journal: BMC Pediatr Date: 2017-07-17 Impact factor: 2.125