Literature DB >> 14595042

A randomized, controlled trial comparing two different continuous positive airway pressure systems for the successful extubation of extremely low birth weight infants.

Beatrice M Stefanescu1, W Paul Murphy, Brenda J Hansell, Mamta Fuloria, Timothy M Morgan, Judy L Aschner.   

Abstract

OBJECTIVE: To determine whether the use of the Infant Flow continuous positive airway pressure (IF CPAP) system reduces the rate of extubation failure among extremely low birth weight (ELBW) infants (infants with birth weight <1000 g) when compared with conventional CPAP delivered with a conventional ventilator and nasal prongs.
METHODS: A prospective, unmasked, randomized, controlled clinical trial was conducted in 162 eligible intubated ELBW infants who were hospitalized in 2 intensive care nurseries in Winston-Salem, North Carolina, between July 1997 and November 2000. Successful extubation was defined as no need for reintubation for any reason for at least 7 days after the first extubation attempt.
RESULTS: The individual extubation success rates were 61.9% (52 of 84) in the conventional CPAP group and 61.5% (48 of 78) in the IF CPAP group. There were no significant differences in the extubation success rate in any birth weight subset between the 2 cohorts. The most common cause of extubation failure was apnea/bradycardia. Infants who were randomized to IF CPAP had fewer days on supplemental O(2) and shorter hospital stays.
CONCLUSIONS: Extubation failure is a common problem, occurring in nearly 40% of ELBW infants who require mechanical ventilation. IF CPAP was as effective but no more effective than conventional CPAP in preventing extubation failure among ELBW infants. New strategies are needed to identify predictors of extubation success and to treat apnea/bradycardia, the most common cause of extubation failure, thereby reducing the likelihood of prolonged intubation in this high-risk cohort of premature infants.

Entities:  

Mesh:

Year:  2003        PMID: 14595042     DOI: 10.1542/peds.112.5.1031

Source DB:  PubMed          Journal:  Pediatrics        ISSN: 0031-4005            Impact factor:   7.124


  26 in total

Review 1.  CPAP review.

Authors:  Olie Chowdhury; Catherine J Wedderburn; Donovan Duffy; Anne Greenough
Journal:  Eur J Pediatr       Date:  2011-12-16       Impact factor: 3.183

2.  Influence of three nasal continuous positive airway pressure devices on breathing pattern in preterm infants.

Authors:  Hocine Boumecid; Thameur Rakza; Abdel Abazine; Serge Klosowski; Régis Matran; Laurent Storme
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2006-11-06       Impact factor: 5.747

3.  Predicting successful extubation of very low birthweight infants.

Authors:  C O F Kamlin; P G Davis; C J Morley
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2006-01-12       Impact factor: 5.747

4.  Nasal masks or binasal prongs for delivering continuous positive airway pressure in preterm neonates-a randomised trial.

Authors:  Aparna Chandrasekaran; Anu Thukral; M Jeeva Sankar; Ramesh Agarwal; Vinod K Paul; Ashok K Deorari
Journal:  Eur J Pediatr       Date:  2017-01-13       Impact factor: 3.183

5.  Factors affecting nasal intermittent positive pressure ventilation failure and impact on bronchopulmonary dysplasia in neonates.

Authors:  P Mehta; J Berger; E Bucholz; V Bhandari
Journal:  J Perinatol       Date:  2014-05-29       Impact factor: 2.521

6.  A new device for administration of continuous positive airway pressure in preterm infants: comparison with a standard nasal CPAP continuous positive airway pressure system.

Authors:  Daniele Trevisanuto; Nicoletta Grazzina; Nicoletta Doglioni; Paola Ferrarese; Francesco Marzari; Vincenzo Zanardo
Journal:  Intensive Care Med       Date:  2005-04-19       Impact factor: 17.440

7.  Continuous positive airway pressure (CPAP) vs noninvasive positive pressure ventilation (NIPPV) vs noninvasive high frequency oscillation ventilation (NHFOV) as post-extubation support in preterm neonates: protocol for an assessor-blinded, multicenter, randomized controlled trial.

Authors:  Yuan Shi; Daniele De Luca
Journal:  BMC Pediatr       Date:  2019-07-26       Impact factor: 2.125

8.  Non-invasive ventilation and surfactant treatment as the primary mode of respiratory support in surfactant-deficient newborn piglets.

Authors:  Carmen Rey-Santano; Victoria E Mielgo; Miguel Angel Gomez-Solaetxe; Francesca Ricci; Federico Bianco; Fabrizio Salomone; Begoña Loureiro; Jon López de Heredia Y Goya
Journal:  Pediatr Res       Date:  2018-02-14       Impact factor: 3.756

9.  Markers of Successful Extubation in Extremely Preterm Infants, and Morbidity After Failed Extubation.

Authors:  Sanjay Chawla; Girija Natarajan; Seetha Shankaran; Benjamin Carper; Luc P Brion; Martin Keszler; Waldemar A Carlo; Namasivayam Ambalavanan; Marie G Gantz; Abhik Das; Neil Finer; Ronald N Goldberg; C Michael Cotten; Rosemary D Higgins
Journal:  J Pediatr       Date:  2017-06-07       Impact factor: 4.406

10.  Synchronized nasal intermittent positive-pressure ventilation and neonatal outcomes.

Authors:  Vineet Bhandari; Neil N Finer; Richard A Ehrenkranz; Shampa Saha; Abhik Das; Michele C Walsh; William A Engle; Krisa P VanMeurs
Journal:  Pediatrics       Date:  2009-07-27       Impact factor: 7.124

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.