Literature DB >> 16408272

Generalized self-navigated motion detection technique: Preliminary investigation in abdominal imaging.

Anja C S Brau1, Jean H Brittain.   

Abstract

Patient motion remains a primary obstacle to diagnostic image quality, especially in the abdomen, despite the existence of various motion artifact reduction techniques. This work presents a self-navigated motion detection method that can be generalized for most pulse sequences and k-space trajectories. Motion information is extracted directly from raw MR data, requiring no additional gradient or RF pulses, no physiologic monitoring equipment, and minimal--if any--impact on scan time. Initial feasibility results with a two-dimensional gradient echo sequence are shown in phantom studies and in vivo volunteer abdominal studies, demonstrating the sensitivity of the method to both respiratory motion and cardiovascular pulsatility. Prospectively gated images were acquired using the self-navigated data to synchronize image acquisition with motion. These preliminary results suggest that the self-navigated method is a promising technique for reducing motion artifacts in clinical abdominal and cardiac applications. Copyright 2006 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2006        PMID: 16408272     DOI: 10.1002/mrm.20785

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  37 in total

1.  Nonrigid motion correction in 3D using autofocusing with localized linear translations.

Authors:  Joseph Y Cheng; Marcus T Alley; Charles H Cunningham; Shreyas S Vasanawala; John M Pauly; Michael Lustig
Journal:  Magn Reson Med       Date:  2012-02-03       Impact factor: 4.668

2.  k-t accelerated aortic 4D flow MRI in under two minutes: Feasibility and impact of resolution, k-space sampling patterns, and respiratory navigator gating on hemodynamic measurements.

Authors:  Emilie Bollache; Alex J Barker; Ryan Scott Dolan; James C Carr; Pim van Ooij; Rouzbeh Ahmadian; Alex Powell; Jeremy D Collins; Julia Geiger; Michael Markl
Journal:  Magn Reson Med       Date:  2017-03-07       Impact factor: 4.668

3.  Flow-compensated self-gating.

Authors:  Jessica Schulz; Matthias Korn; Michael Deimling; Wolfhard Semmler; Michael Bock
Journal:  MAGMA       Date:  2008-07-31       Impact factor: 2.310

Review 4.  Motion artifacts in MRI: A complex problem with many partial solutions.

Authors:  Maxim Zaitsev; Julian Maclaren; Michael Herbst
Journal:  J Magn Reson Imaging       Date:  2015-01-28       Impact factor: 4.813

5.  Multiparametric oxygen-enhanced functional lung imaging in 3D.

Authors:  Kathrin R F Hemberger; Peter M Jakob; Felix A Breuer
Journal:  MAGMA       Date:  2014-10-09       Impact factor: 2.310

6.  Self-gated fat-suppressed cardiac cine MRI.

Authors:  R Reeve Ingle; Juan M Santos; William R Overall; Michael V McConnell; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2014-05-07       Impact factor: 4.668

7.  Respiratory self-gating for free-breathing magnetization transfer MRI of the abdomen.

Authors:  Weiguo Li; Zhuoli Zhang; Kangan Li; Ning Jin; Yue Zhang; Tianjing Zhang; Frank H Miller; Andrew C Larson
Journal:  Magn Reson Med       Date:  2014-06-24       Impact factor: 4.668

8.  Multiple overlapping k-space junctions for investigating translating objects (MOJITO).

Authors:  Candice A Bookwalter; Mark A Griswold; Jeffrey L Duerk
Journal:  IEEE Trans Med Imaging       Date:  2009-08-25       Impact factor: 10.048

9.  Optimized 3D ultrashort echo time pulmonary MRI.

Authors:  Kevin M Johnson; Sean B Fain; Mark L Schiebler; Scott Nagle
Journal:  Magn Reson Med       Date:  2012-12-04       Impact factor: 4.668

10.  Robust self-navigated body MRI using dense coil arrays.

Authors:  Tao Zhang; Joseph Y Cheng; Yuxin Chen; Dwight G Nishimura; John M Pauly; Shreyas S Vasanawala
Journal:  Magn Reson Med       Date:  2015-07-29       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.