Literature DB >> 16404491

Characterization of the structure and properties of authentic and counterfeit polypropylene surgical meshes.

M K McDermott1, I S Isayeva, T M Thomas, A S Lee, A D Lucas, C N Witkowski, J C Hutter.   

Abstract

A counterfeit version of the Ethicon Prolene polypropylene mesh was distributed to hospitals and clinics and unintentionally implanted into patients undergoing tension-free hernia repair. On December 19, 2003, the Food and Drug Administration (FDA) issued a public health web notification indicating that the counterfeit mesh was not sterile or safe to use. To develop safety recommendations for patients with the counterfeit mesh implant, we compared the counterfeit's structural, physical, chemical and mechanical properties with polypropylene meshes previously cleared by FDA. The mesh fibers for all the products tested were found to have similar chemical and physical properties. The mechanical properties were directly related to the knitted structure (loop size, repeat distance, fabric tightness) and the porosity. Extracts from the counterfeit mesh passed cytotoxicity screening tests. The FDA further recommended that if the mesh had been inadvertently implanted, then those patients should be monitored as would be the practice for any patient with an implanted surgical mesh.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16404491     DOI: 10.1007/s10029-005-0042-6

Source DB:  PubMed          Journal:  Hernia        ISSN: 1248-9204            Impact factor:   4.739


  11 in total

1.  Functional impairment and complaints following incisional hernia repair with different polypropylene meshes.

Authors:  G Welty; U Klinge; B Klosterhalfen; R Kasperk; V Schumpelick
Journal:  Hernia       Date:  2001-09       Impact factor: 4.739

2.  Structural alterations of prosthetic meshes in humans.

Authors:  A Coda; R Bendavid; F Botto-Micca; M Bossotti; A Bona
Journal:  Hernia       Date:  2002-10-18       Impact factor: 4.739

3.  Elasticity of the anterior abdominal wall and impact for reparation of incisional hernias using mesh implants.

Authors:  K Junge; U Klinge; A Prescher; P Giboni; M Niewiera; V Schumpelick
Journal:  Hernia       Date:  2001-09       Impact factor: 4.739

4.  Spectral dependence of UV-induced immediate and delayed apoptosis: the role of membrane and DNA damage.

Authors:  D E Godar; A D Lucas
Journal:  Photochem Photobiol       Date:  1995-07       Impact factor: 3.421

5.  The influence of differing pore sizes on the biocompatibility of two polypropylene meshes in the repair of abdominal defects. Experimental study in dogs.

Authors:  F H Greca; J B de Paula; M L Biondo-Simões; F D da Costa; A P da Silva; S Time; A Mansur
Journal:  Hernia       Date:  2001-06       Impact factor: 4.739

6.  Modified mesh for hernia repair that is adapted to the physiology of the abdominal wall.

Authors:  U Klinge; B Klosterhalfen; J Conze; W Limberg; B Obolenski; A P Ottinger; V Schumpelick
Journal:  Eur J Surg       Date:  1998-12

7.  Comparison of biomaterials in the early postoperative period.

Authors:  M R Langenbach; J Schmidt; H Zirngibl
Journal:  Surg Endosc       Date:  2003-05-06       Impact factor: 4.584

Review 8.  Features of apoptotic cells measured by flow cytometry.

Authors:  Z Darzynkiewicz; S Bruno; G Del Bino; W Gorczyca; M A Hotz; P Lassota; F Traganos
Journal:  Cytometry       Date:  1992

9.  Mesh implants in hernia repair. Inflammatory cell response in a rat model.

Authors:  R Rosch; K Junge; A Schachtrupp; U Klinge; B Klosterhalfen; V Schumpelick
Journal:  Eur Surg Res       Date:  2003 May-Jun       Impact factor: 1.745

10.  Analysis and discrimination of necrosis and apoptosis (programmed cell death) by multiparameter flow cytometry.

Authors:  C Dive; C D Gregory; D J Phipps; D L Evans; A E Milner; A H Wyllie
Journal:  Biochim Biophys Acta       Date:  1992-02-03
View more
  3 in total

Review 1.  Mesh repair of common abdominal hernias: a review on experimental and clinical studies.

Authors:  R Penttinen; J M Grönroos
Journal:  Hernia       Date:  2008-03-20       Impact factor: 4.739

2.  Recurrent inguinal hernia due to mesh dissolution: two case reports.

Authors:  M Shamim
Journal:  Hernia       Date:  2009-07-28       Impact factor: 4.739

3.  Physical Characteristics of Medical Textile Prostheses Designed for Hernia Repair: A Comprehensive Analysis of Select Commercial Devices.

Authors:  Linli Miao; Fang Wang; Lu Wang; Ting Zou; Gaétan Brochu; Robert Guidoin
Journal:  Materials (Basel)       Date:  2015-12-02       Impact factor: 3.623

  3 in total