M R Langenbach1, J Schmidt, H Zirngibl. 1. Department of Surgery, University Witten-Herdecke, Helios Klinikum, Heusner-Strasse 40, D-42283 Wuppertal, Germany. MRLangenbach@aol.com
Abstract
BACKGROUND:Laparoscopic hernia repair necessitates the use of biocompatible materials. A prospective, double-blind study was conducted to compare two different polypropylene meshes. METHODS: The study included 40 men with primary inguinal hernia undergoing transabdominal preperitoneal polypropylene mesh repair. In 20 of these men, a monofile, heavy-weight, rigid mesh was implanted (group A), and in the remaining 20 men, a smooth, heavy-weight variant of polypropylene mesh was implanted (group B). Complications, pain development, inability to work, physical conditions, testicular volume, and blood circulation were documented. RESULTS: Reconvalescence in group A was slower than in group B. In group A, the postoperative values of the visual scales for pain development were higher; inability to work was 7.3 days longer; urologic disorders were worse; activities of everyday life were more reduced; and SF-36 data showed a significant reduction of physical problems ( p < 0.05). CONCLUSIONS: The polypropylene mesh variant seems to be more compatible with the human organism than conventional mesh. Not only the material, but also the structure seems to influence the comfort of the mesh.
RCT Entities:
BACKGROUND: Laparoscopic hernia repair necessitates the use of biocompatible materials. A prospective, double-blind study was conducted to compare two different polypropylene meshes. METHODS: The study included 40 men with primary inguinal hernia undergoing transabdominal preperitoneal polypropylene mesh repair. In 20 of these men, a monofile, heavy-weight, rigid mesh was implanted (group A), and in the remaining 20 men, a smooth, heavy-weight variant of polypropylene mesh was implanted (group B). Complications, pain development, inability to work, physical conditions, testicular volume, and blood circulation were documented. RESULTS: Reconvalescence in group A was slower than in group B. In group A, the postoperative values of the visual scales for pain development were higher; inability to work was 7.3 days longer; urologic disorders were worse; activities of everyday life were more reduced; and SF-36 data showed a significant reduction of physical problems ( p < 0.05). CONCLUSIONS: The polypropylene mesh variant seems to be more compatible with the human organism than conventional mesh. Not only the material, but also the structure seems to influence the comfort of the mesh.
Authors: M P Simons; T Aufenacker; M Bay-Nielsen; J L Bouillot; G Campanelli; J Conze; D de Lange; R Fortelny; T Heikkinen; A Kingsnorth; J Kukleta; S Morales-Conde; P Nordin; V Schumpelick; S Smedberg; M Smietanski; G Weber; M Miserez Journal: Hernia Date: 2009-07-28 Impact factor: 4.739
Authors: G Chatzimavroudis; I Koutelidakis; B Papaziogas; T Tsaganos; P Koutoukas; E Giamarellos-Bourboulis; S Atmatzidis; K Atmatzidis Journal: Hernia Date: 2008-01-10 Impact factor: 4.739
Authors: A Yazdankhah Kenary; S N Afshin; H Ahmadi Amoli; A Yagoobi Notash; A Borjian; A Yagoobi Notash; S Shafaattalab; G Shafiee Journal: Hernia Date: 2012-11-09 Impact factor: 4.739