Literature DB >> 16386983

Comparison of retinal nerve fiber layer thickness and optic disk algorithms with optical coherence tomography to detect glaucoma.

Anita Manassakorn1, Kouros Nouri-Mahdavi, Joseph Caprioli.   

Abstract

PURPOSE: To compare the performance of the retinal nerve fiber layer (RNFL) thickness and optic disk algorithms as determined by optical coherence tomography to detect glaucoma.
DESIGN: Observational cross-sectional study.
METHODS: setting: Academic tertiary-care center. study population: One eye from 42 control subjects and 65 patients with open-angle glaucoma with visual acuity of > or =20/40, and no other ocular pathologic condition. observation procedures: Two optical coherence tomography algorithms were used: "fast RNFL thickness" and "fast optic disk." main outcome measures: Area under the receiver operating characteristic curves and sensitivities at fixed specificities were used. Discriminating ability of the average RNFL thickness and RNFL thickness in clock-hour sectors and quadrants was compared with the parameters that were derived from the fast optic disk algorithm. Classification and regression trees were used to determine the best combination of parameters for the detection of glaucoma.
RESULTS: The average visual field mean deviation (+/-SD) was 0.0 +/- 1.3 and -5.3 +/- 5.0 dB in the control and glaucoma groups, respectively. The RNFL thickness at the 7 o'clock sector, inferior quadrant, and the vertical C/D ratio had the highest area under the receiver operating characteristic curves (0.93 +/- 0.02, 0.92 +/- 0.03, and 0.90 +/- 0.03, respectively). At 90% specificity, the best sensitivities (+/-SE) from each algorithm were 86% +/- 3% for RNFL thickness at the 7 o'clock sector and 79% +/- 4% for horizontal integrated rim width (estimated rim area). The combination of inferior quadrant RNFL thickness and vertical C/D ratio achieved the best classification (misclassification rate, 6.2%).
CONCLUSION: The fast optic disk algorithm performs as well as the fast RNFL thickness algorithm for discrimination of glaucoma from normal eyes. A combination of the two algorithms may provide enhanced diagnostic performance.

Entities:  

Mesh:

Year:  2006        PMID: 16386983     DOI: 10.1016/j.ajo.2005.08.023

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  27 in total

1.  Ability of cirrus HD-OCT optic nerve head parameters to discriminate normal from glaucomatous eyes.

Authors:  Jean-Claude Mwanza; Jonathan D Oakley; Donald L Budenz; Douglas R Anderson
Journal:  Ophthalmology       Date:  2010-10-28       Impact factor: 12.079

2.  Asymmetry in hemifield macular thickness as an early indicator of glaucomatous change.

Authors:  Tae Woong Um; Kyung Rim Sung; Gadi Wollstein; Sung-Cheol Yun; Jung Hwa Na; Joel S Schuman
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-03-02       Impact factor: 4.799

Review 3.  Imaging of the retinal nerve fibre layer with spectral domain optical coherence tomography for glaucoma diagnosis.

Authors:  Kyung Rim Sung; Jong S Kim; Gadi Wollstein; Lindsey Folio; Michael S Kook; Joel S Schuman
Journal:  Br J Ophthalmol       Date:  2010-10-28       Impact factor: 4.638

4.  Correlation between retinal morphological and functional findings and clinical severity in Parkinson's disease.

Authors:  Ozgül Altintaş; Pervin Işeri; Berna Ozkan; Yusuf Cağlar
Journal:  Doc Ophthalmol       Date:  2007-10-26       Impact factor: 2.379

5.  Agreement between optical coherence tomography and digital stereophotography in vertical cup-to-disc ratio measurement.

Authors:  Giacomo Savini; Edgar M Espana; Ana Carolina Acosta; Michele Carbonelli; Costantino Bellusci; Piero Barboni
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-10-29       Impact factor: 3.117

6.  Comparison of ability of time-domain and spectral-domain optical coherence tomography to detect diffuse retinal nerve fiber layer atrophy.

Authors:  Ko Eun Kim; Seok Hwan Kim; Jin Wook Jeoung; Ki Ho Park; Tae Woo Kim; Dong Myung Kim
Journal:  Jpn J Ophthalmol       Date:  2013-09-03       Impact factor: 2.447

7.  Combination of optic disc rim area and retinal nerve fiber layer thickness for early glaucoma detection by using spectral domain OCT.

Authors:  Min Hee Suh; Sun Kwon Kim; Ki Ho Park; Dong Myung Kim; Seok Hwan Kim; Hee Chan Kim
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-09-25       Impact factor: 3.117

8.  Evaluation of optic nerve head and retinal nerve fiber layer in early and advance glaucoma using frequency-domain optical coherence tomography.

Authors:  Songfeng Li; Xiaozhen Wang; Shuning Li; Gewei Wu; Ningli Wang
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-11-25       Impact factor: 3.117

9.  Discriminating ability of spectral domain optical coherence tomography in different stages of glaucoma.

Authors:  Amal M Elbendary; Randa Mohamed Helal
Journal:  Saudi J Ophthalmol       Date:  2012-10-11

10.  Predicting progressive glaucomatous optic neuropathy using baseline standard automated perimetry data.

Authors:  Shaban Demirel; Brad Fortune; Juanjuan Fan; Richard A Levine; Rodrigo Torres; Hau Nguyen; Steven L Mansberger; Stuart K Gardiner; George A Cioffi; Chris A Johnson
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-10-20       Impact factor: 4.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.