Literature DB >> 16386969

Predicting patients' night vision complaints with wavefront technology.

Kuang-Mon Ashley Tuan1, Dimitri Chernyak, Sandy T Feldman.   

Abstract

PURPOSE: To evaluate the accuracy of the diagnostic capabilities of optical metrics generated from wavefront measurements in relationship to post-laser-assisted in situ keratomileusis (LASIK) visual complaints as expressed and drawn by patients.
DESIGN: Retrospective analysis and observational case series.
METHODS: Patient wavefront data from an investigational device exemption study for wavefront-guided ablations were used to derive normative modulation transfer function (MTF), encircled energy (EE), and Strehl ratio. These optical metrics and their point-spread functions (PSF) were compared with data from five postoperative patients with night vision complaints. Patients were asked to draw their symptoms, which were elicited by testing with a Fenthoff muscle light, while using their best-corrected distance vision.
RESULTS: The MTF, EE, and Strehl ratio of most patients were markedly different from those of the averages of 208 normal myopic eyes before and after LASIK surgery. The spatial extent of the PSF correlated positively with the severity of the visual complaints. Wavefront-derived PSFs were markedly similar to the patients' drawings.
CONCLUSIONS: The results of this study demonstrate the diagnostic capability of the wavefront system in predicting visual symptoms and complaints of patients with high-order aberrations. Objective visual metrics from patients with night vision complaints were different from those of normal myopic eyes that had undergone LASIK procedures.

Entities:  

Mesh:

Year:  2006        PMID: 16386969     DOI: 10.1016/j.ajo.2005.08.065

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  7 in total

1.  [Wavefront aberrations and subjective quality of vision after wavefront-guided LASIK: first results].

Authors:  J Bühren; A Strenger; T Martin; T Kohnen
Journal:  Ophthalmologe       Date:  2007-08       Impact factor: 1.059

2.  [Aspheric profiles for refractive laser ablation of the cornea].

Authors:  Th Neuhann; I M Neuhann; J M Hassel
Journal:  Ophthalmologe       Date:  2008-03       Impact factor: 1.059

3.  Objective functional visual outcomes of cataract surgery in patients with good preoperative visual acuity.

Authors:  X Zhu; H Ye; W He; J Yang; J Dai; Y Lu
Journal:  Eye (Lond)       Date:  2016-11-18       Impact factor: 3.775

4.  The effects of implantable collamer lens implantation on higher order aberrations.

Authors:  Belma Kayhan; Efekan Coskunseven; Onurcan Sahin; Ioannis Pallikaris
Journal:  Int J Ophthalmol       Date:  2019-12-18       Impact factor: 1.779

5.  Evaluation of optical quality parameters and ocular aberrations in multifocal intraocular lens implanted eyes.

Authors:  Hun Lee; Kwanghyun Lee; Ji Min Ahn; Eung Kweon Kim; Bradford Sgrignoli; Tae-im Kim
Journal:  Yonsei Med J       Date:  2014-09       Impact factor: 2.759

6.  Comparison of outcomes of laser refractive surgery (LRS) alone and LRS with laser asymmetric keratectomy in patients with myopia: A retrospective study.

Authors:  Ji Sang Min; Byung Moo Min
Journal:  Medicine (Baltimore)       Date:  2021-04-09       Impact factor: 1.817

7.  Does intraocular straylight predict night driving visual performance? Correlations between straylight levels and contrast sensitivity, halo size, and hazard recognition distance with and without glare.

Authors:  Judith Ungewiss; Ulrich Schiefer; Peter Eichinger; Michael Wörner; David P Crabb; Pete R Jones
Journal:  Front Hum Neurosci       Date:  2022-09-13       Impact factor: 3.473

  7 in total