Literature DB >> 18311567

[Aspheric profiles for refractive laser ablation of the cornea].

Th Neuhann1, I M Neuhann, J M Hassel.   

Abstract

Conventional ablation profiles for excimer lasers for myopic refractive correction of the cornea are of spheric geometry. Therefore, they induce additional imaging aberrations into the optical system of the eye, most notably spherical aberration. This is a major cause of the observed deterioration of visual quality after such corrections, especially under low illumination and ensuing larger pupil diameter. Therefore, aspheric ablation profiles compromizing the preexisting imaging/visual quality of the eye as little as possible are currently being developed and optimized for all laser platforms. Employed methods include customized correction profiles on the basis of individual wavefront data of the anterior corneal topography on the one hand, and correction profiles that minimize the induced spherical aberration in a "standardized" way on the other hand. We demonstrate for a particular laser platform how such profiles must be developed and optimized. Mathematical theoretical calculations appear to be an indispensable but insufficient prerequisite. The biological reaction of the corneal stroma and epithelium ("biodynamic response") can only be determined experimentally and must lead to adjustment of the calculated ablation algorithm. The results show that aspheric profiles developed on this basis can lead to significant reduction of induced spherical aberration. The obtainable effect is, however, limited by the biological response and the ensuing peripheral ablation depth and volume.

Entities:  

Mesh:

Year:  2008        PMID: 18311567     DOI: 10.1007/s00347-008-1723-1

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  35 in total

1.  Ocular aberrations before and after myopic corneal refractive surgery: LASIK-induced changes measured with laser ray tracing.

Authors:  E Moreno-Barriuso; J M Lloves; S Marcos; R Navarro; L Llorente; S Barbero
Journal:  Invest Ophthalmol Vis Sci       Date:  2001-05       Impact factor: 4.799

Review 2.  Customized corneal ablation.

Authors:  Theo Seiler; Mohammad H Dastjerdi
Journal:  Curr Opin Ophthalmol       Date:  2002-08       Impact factor: 3.761

3.  Wavefront-optimized ablation profiles: theoretical background.

Authors:  Michael Mrochen; Christof Donitzky; Christian Wüllner; Joachim Löffler
Journal:  J Cataract Refract Surg       Date:  2004-04       Impact factor: 3.351

4.  Optical response to LASIK surgery for myopia from total and corneal aberration measurements.

Authors:  S Marcos; S Barbero; L Llorente; J Merayo-Lloves
Journal:  Invest Ophthalmol Vis Sci       Date:  2001-12       Impact factor: 4.799

5.  Q-factor customized ablation profile for the correction of myopic astigmatism.

Authors:  Tobias Koller; Hans Peter Iseli; Farhad Hafezi; Michael Mrochen; Theo Seiler
Journal:  J Cataract Refract Surg       Date:  2006-04       Impact factor: 3.351

6.  Higher order wavefront aberrations of cornea and magnitude of refractive correction in laser in situ keratomileusis.

Authors:  Tetsuro Oshika; Kazunori Miyata; Tadatoshi Tokunaga; Tomokazu Samejima; Shiro Amano; Sumiyoshi Tanaka; Yoko Hirohara; Toshifumi Mihashi; Naoyuki Maeda; Takashi Fujikado
Journal:  Ophthalmology       Date:  2002-06       Impact factor: 12.079

Review 7.  Refractive surgery, optical aberrations, and visual performance.

Authors:  R A Applegate; H C Howland
Journal:  J Refract Surg       Date:  1997 May-Jun       Impact factor: 3.573

8.  [Aspheric optics: physical fundamentals].

Authors:  M Mrochen; M Büeler
Journal:  Ophthalmologe       Date:  2008-03       Impact factor: 1.059

9.  US trends in refractive surgery: 2004 ISRS/AAO Survey.

Authors:  Richard J Duffey; David Leaming
Journal:  J Refract Surg       Date:  2005 Nov-Dec       Impact factor: 3.573

10.  Correlation of wavefront data and corneal asphericity with contrast sensitivity after laser in situ keratomileusis for myopia.

Authors:  Mihai Pop; Yves Payette
Journal:  J Refract Surg       Date:  2004 Sep-Oct       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.