Literature DB >> 16382618

Comparative evaluation of despeckle filtering in ultrasound imaging of the carotid artery.

Christos P Loizou1, Constantinos S Pattichis, Christodoulos I Christodoulou, Robert S H Istepanian, Marios Pantziaris, Andrew Nicolaides.   

Abstract

It is well-known that speckle is a multiplicative noise that degrades the visual evaluation in ultrasound imaging. The recent advancements in ultrasound instrumentation and portable ultrasound devices necessitate the need of more robust despeckling techniques for enhanced ultrasound medical imaging for both routine clinical practice and teleconsultation. The objective of this work was to carry out a comparative evaluation of despeckle filtering based on texture analysis, image quality evaluation metrics, and visual evaluation by medical experts in the assessment of 440 (220 asymptomatic and 220 symptomatic) ultrasound images of the carotid artery bifurcation. In this paper a total of 10 despeckle filters were evaluated based on local statistics, median filtering, pixel homogeneity, geometric filtering, homomorphic filtering, anisotropic diffusion, nonlinear coherence diffusion, and wavelet filtering. The results of this study suggest that the first order statistics filter lsmv, gave the best performance, followed by the geometric filter gf4d, and the homogeneous mask area filter lsminsc. These filters improved the class separation between the asymptomatic and the symptomatic classes based on the statistics of the extracted texture features, gave only a marginal improvement in the classification success rate, and improved the visual assessment carried out by the two experts. More specifically, filters lsmv or gf4d can be used for despeckling asymptomatic images in which the expert is interested mainly in the plaque composition and texture analysis; and filters lsmv, gf4d, or lsminsc can be used for the despeckling of symptomatic images in which the expert is interested in identifying the degree of stenosis and the plaque borders. The proper selection of a despeckle filter is very important in the enhancement of ultrasonic imaging of the carotid artery. Further work is needed to evaluate at a larger scale and in clinical practice the performance of the proposed despeckle filters in the automated segmentation, texture analysis, and classification of carotid ultrasound imaging.

Mesh:

Year:  2005        PMID: 16382618     DOI: 10.1109/tuffc.2005.1561621

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  23 in total

1.  Accurate ultrasound imaging based on range point migration method for the depiction of fetal surface.

Authors:  Hirofumi Taki; Shinya Tanimura; Takuya Sakamoto; Tsuyoshi Shiina; Toru Sato
Journal:  J Med Ultrason (2001)       Date:  2014-09-13       Impact factor: 1.314

2.  Denoising of Ultrasound Cervix Image Using Improved Anisotropic Diffusion Filter.

Authors:  R Jemila Rose; S Allwin
Journal:  West Indian Med J       Date:  2015-05-13       Impact factor: 0.171

3.  A comparative study of new and current methods for dental micro-CT image denoising.

Authors:  Mahdi Shahmoradi; Mojtaba Lashgari; Hossein Rabbani; Jie Qin; Michael Swain
Journal:  Dentomaxillofac Radiol       Date:  2016-01-14       Impact factor: 2.419

4.  Snakes based segmentation of the common carotid artery intima media.

Authors:  C P Loizou; C S Pattichis; M Pantziaris; T Tyllis; A Nicolaides
Journal:  Med Biol Eng Comput       Date:  2007-01-03       Impact factor: 2.602

5.  Quality evaluation of ultrasound imaging in the carotid artery based on normalization and speckle reduction filtering.

Authors:  C P Loizou; C S Pattichis; M Pantziaris; T Tyllis; A Nicolaides
Journal:  Med Biol Eng Comput       Date:  2006-04-11       Impact factor: 2.602

6.  Artifact removal and texture-based rendering for visualization of 3D fetal ultrasound images.

Authors:  Shyh-Roei Wang; Yung-Nien Sun; Fong-Ming Chang
Journal:  Med Biol Eng Comput       Date:  2007-12-18       Impact factor: 2.602

7.  Assessment of intima-media thickness of carotid arteries: evaluation of an automated computer software.

Authors:  Stefan Puchner; Markus Reiter; Christos Baros; Erich Minar; Johannes Lammer; Robert A Bucek
Journal:  Neuroradiology       Date:  2008-06-12       Impact factor: 2.804

8.  A New Method for Diaphragmatic Maximum Relaxation Rate Ultrasonographic Measurement in the Assessment of Patients With Diaphragmatic Dysfunction.

Authors:  Christos P Loizou; Dimitrios Matamis; Giorgos Minas; Theodoros Kyprianou; Christakis D Loizou; Eleni Soilemezi; Entela Kotco; Constantinos S Pattichis
Journal:  IEEE J Transl Eng Health Med       Date:  2018-10-11       Impact factor: 3.316

9.  CAUDLES-EF: carotid automated ultrasound double line extraction system using edge flow.

Authors:  Filippo Molinari; Kristen M Meiburger; Guang Zeng; Andrew Nicolaides; Jasjit S Suri
Journal:  J Digit Imaging       Date:  2011-12       Impact factor: 4.056

10.  Completely automated robust edge snapper for carotid ultrasound IMT measurement on a multi-institutional database of 300 images.

Authors:  Filippo Molinari; U Rajendra Acharya; Guang Zeng; Kristen M Meiburger; Jasjit S Suri
Journal:  Med Biol Eng Comput       Date:  2011-04-21       Impact factor: 2.602

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.