Literature DB >> 16381776

Measurements of secondary neutron dose from 15 MV and 18 MV IMRT.

Rebecca M Howell1, Michele S Ferenci, Nolan E Hertel, Gary D Fullerton, Timothy Fox, Lawrence W Davis.   

Abstract

Secondary neutron dose-equivalents were determined for conventional and intensity modulated radiation therapy (IMRT) prostate treatments for 15 and 18 MV X-ray beams. Conventional and IMRT treatment plans were generated to deliver 45 Gy to the prostate, seminal vessicles and external and internal iliac lymph nodes. Neutron spectra were determined by unfolding measurements from a TLD-based Bonner sphere system. Treatments using 18 MV IMRT and conventional plans result in neutron ambient dose-equivalents of 687 and 112 mSv, respectively. Delivery of the 15 MV IMRT and conventional plans results in neutron ambient dose-equivalents of 327 and 52 mSv, respectively. The data illustrate that using lower photon energies for IMRT reduces the secondary neutron dose, while still achieving comparable treatment volume coverage and sparing critical normal tissue.

Mesh:

Year:  2005        PMID: 16381776     DOI: 10.1093/rpd/nci041

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  7 in total

1.  Microdosimetric measurements in the secondary radiation field produced in (12)C-therapy irradiations.

Authors:  F Wissmann; U Giesen; T Klages; D Schardt; G Martino; C Sunil
Journal:  Radiat Environ Biophys       Date:  2010-03-26       Impact factor: 1.925

2.  Neutron spectra and dose equivalents calculated in tissue for high-energy radiation therapy.

Authors:  Stephen F Kry; Rebecca M Howell; Mohammad Salehpour; David S Followill
Journal:  Med Phys       Date:  2009-04       Impact factor: 4.071

3.  A new analytical formula for neutron capture gamma dose calculations in double-bend mazes in radiation therapy.

Authors:  Hosein Ghiasi; Asghar Mesbahi
Journal:  Rep Pract Oncol Radiother       Date:  2012-05-24

4.  Applicability of self-activation of an NaI scintillator for measurement of photo-neutrons around a high-energy X-ray radiotherapy machine.

Authors:  Genichiro Wakabayashi; Akihiro Nohtomi; Eriko Yahiro; Toshioh Fujibuchi; Junichi Fukunaga; Yoshiyuki Umezu; Yasuhiko Nakamura; Katsumasa Nakamura; Makoto Hosono; Tetsuo Itoh
Journal:  Radiol Phys Technol       Date:  2014-11-18

5.  Secondary neutron spectrum from 250-MeV passively scattered proton therapy: measurement with an extended-range Bonner sphere system.

Authors:  Rebecca M Howell; E A Burgett
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

6.  Micronuclei in human peripheral blood lymphocytes exposed to mixed beams of X-rays and alpha particles.

Authors:  Elina Staaf; Karl Brehwens; Siamak Haghdoost; Sander Nievaart; Katerina Pachnerova-Brabcova; Joanna Czub; Janusz Braziewicz; Andrzej Wojcik
Journal:  Radiat Environ Biophys       Date:  2012-04-24       Impact factor: 1.925

7.  The influence of shielding reinforcement in a vault with limited dimensions on the neutron dose equivalent in vicinity of medical electron linear accelerator.

Authors:  Ana Ivkovic; Dario Faj; Mladen Kasabasic; Marina Poje Sovilj; Ivana Krpan; Marina Grabar Branilovic; Hrvoje Brkic
Journal:  Radiol Oncol       Date:  2020-05-02       Impact factor: 2.991

  7 in total