On the automated definition of mobile target volumes from 4D-CT images for stereotactic body radiotherapy.

Tiezhi Zhang1, Nigel P Orton, Wolfgang A Tomé.   

Abstract

Stereotactic body radiotherapy (SBRT) can be used to treat small lesions in the chest. A vacuum-based immobilization system is used in our clinic for SBRT, and a motion envelope is used in treatment planning. The purpose of this study is to automatically derive motion envelopes using deformable image registration of 4D-CT images, and to assess the effect of abdominal pressure on the motion envelopes. 4D-CT scans at ten phases were acquired prior to treatment for both free and restricted breathing using a vacuum-based immobilization system that includes an abdominal pressure pillow. To study the stability of the motion envelope over the course of treatment, a mid-treatment 4D-CT scan was obtained after delivery of the third fraction for two patients. The planning target volume excluding breathing motion (PTV(ex)) was defined on the image set at full exhalation phase and transformed into all other phases using displacement maps from deformable image registration. The motion envelope was obtained as the union of PTV(ex) masks of all phases. The ratios of the motion envelope to PTV(ex) volume ranged from 1.3 to 2.5. When pressure was applied, the ratios were reduced by as much as 29% compared to free breathing for some patients, but increased by up to 9% for others. The abdominal pressure pillow has more motion restriction effects on the anterior/inferior region of the lung. For one of the two patients for whom the 4D-CT scan was repeated at mid-treatment, the motion envelope was reproducible. However, for the other patient the tumor location and lung motion pattern significantly changed due to changes in the anatomy surrounding the tumor during the course of treatment, indicating that an image-guided approach to SBRT may increase the efficacy of this treatment.

Entities:  

Mesh:

Year:  2005        PMID: 16370433     DOI: 10.1118/1.2106448

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  13 in total

1.  Extraction of tumor motion trajectories using PICCS-4DCBCT: a validation study.

Authors:  Zhihua Qi; Guang-Hong Chen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  Direct measurement of lung motion using hyperpolarized helium-3 MR tagging.

Authors:  Jing Cai; G Wilson Miller; Talissa A Altes; Paul W Read; Stanley H Benedict; Eduard E de Lange; Gordon D Cates; James R Brookeman; John P Mugler; Ke Sheng
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-04-18       Impact factor: 7.038

3.  Comparison of intensity-modulated radiotherapy planning based on manual and automatically generated contours using deformable image registration in four-dimensional computed tomography of lung cancer patients.

Authors:  Elisabeth Weiss; Krishni Wijesooriya; Viswanathan Ramakrishnan; Paul J Keall
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-12-19       Impact factor: 7.038

4.  Improving image-guided radiation therapy of lung cancer by reconstructing 4D-CT from a single free-breathing 3D-CT on the treatment day.

Authors:  Guorong Wu; Jun Lian; Dinggang Shen
Journal:  Med Phys       Date:  2012-12       Impact factor: 4.071

5.  Estimating the 4D respiratory lung motion by spatiotemporal registration and super-resolution image reconstruction.

Authors:  Guorong Wu; Qian Wang; Jun Lian; Dinggang Shen
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

6.  Cumulative lung dose for several motion management strategies as a function of pretreatment patient parameters.

Authors:  Geoffrey D Hugo; Jonathon Campbell; Tiezhi Zhang; Di Yan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-03-26       Impact factor: 7.038

7.  On the impact of longitudinal breathing motion randomness for tomotherapy delivery.

Authors:  Michael W Kissick; Ryan T Flynn; David C Westerly; Peter W Hoban; Xiaohu Mo; Emilie T Soisson; Keisha C McCall; Thomas R Mackie; Robert Jeraj
Journal:  Phys Med Biol       Date:  2008-08-18       Impact factor: 3.609

8.  Performance evaluation of automatic anatomy segmentation algorithm on repeat or four-dimensional computed tomography images using deformable image registration method.

Authors:  He Wang; Adam S Garden; Lifei Zhang; Xiong Wei; Anesa Ahamad; Deborah A Kuban; Ritsuko Komaki; Jennifer O'Daniel; Yongbin Zhang; Radhe Mohan; Lei Dong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-09-01       Impact factor: 7.038

9.  Incidence of rib fractures after stereotactic body radiotherapy for peripheral lung lesions: clinical experience and dose response estimation.

Authors:  Wolfgang A Tomé; C Wesley Hodge; Minesh P Mehta; Søren M Bentzen
Journal:  J Radiosurg SBRT       Date:  2011

10.  Initial clinical experience with stereotactic lung radiotherapy, based on a biological model-driven prescription method.

Authors:  C Wesley Hodge; Wolfgang A Tomé; Tracy Weigel; Anne M Traynor; Minesh P Mehta
Journal:  J Radiosurg SBRT       Date:  2011
View more