Literature DB >> 16360510

Hydroxyapatite cement in craniofacial reconstruction.

D J Verret1, Yadranko Ducic, Lance Oxford, Jesse Smith.   

Abstract

OBJECTIVES: To evaluate the long-term efficacy of hydroxyapatite cement in craniofacial reconstruction, specifically examining the role (if any) of radiation, implant location, and cement type. STUDY
DESIGN: A retrospective chart review was conducted of all patients presenting to the senior surgeon (Y.D.) for craniofacial reconstruction from September 1997 to April 2004.
METHODS: Data were collected including type of cement used, size of defect, complications, need for removal of cement, reason for defect, and pathologic results of examination of removed cements.
RESULTS: One hundred two patients were identified who underwent craniofacial reconstruction with hydroxyapatite cements, 7 of whom required complete implant removal (6 Norian and 1 Mimix), and 4 (2 Norian and 2 Bone source) of whom required partial implant removal for foreign body reaction. Five of the removals were in patients who underwent postoperative radiation.
CONCLUSIONS: Hydroxyapatite cements are safe in craniofacial reconstruction. The highest risk of implant infection comes from reconstruction in the area of the frontal sinus, immediately beneath coronal incisions, and in patients who receive postoperative radiation treatment. Based on our results, there does appear to be a statistically significant difference in rates of infection and foreign body reaction between the different types of hydroxyapatite cement. We would not recommend implantation of this material in contact with the frontal sinus. Caution should be exercised when it is placed directly beneath an incision or in patients receiving postoperative radiation, particularly if a boost dose is given.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16360510     DOI: 10.1016/j.otohns.2005.09.001

Source DB:  PubMed          Journal:  Otolaryngol Head Neck Surg        ISSN: 0194-5998            Impact factor:   3.497


  24 in total

1.  Review of bone substitutes.

Authors:  Landon S Pryor; Earl Gage; Claude-Jean Langevin; Fernando Herrera; Andrew D Breithaupt; Chad R Gordon; Ahmed M Afifi; James E Zins; Hal Meltzer; Amanda Gosman; Steve R Cohen; Ralph Holmes
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2009-10

Review 2.  Bioactive-glass in Oral and Maxillofacial Surgery.

Authors:  Andrea Corrado Profeta; Christoph Huppa
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2015-05-21

Review 3.  A review of reconstructive materials for use in craniofacial surgery bone fixation materials, bone substitutes, and distractors.

Authors:  James Tait Goodrich; Adam L Sandler; Oren Tepper
Journal:  Childs Nerv Syst       Date:  2012-08-08       Impact factor: 1.475

4.  Evaluation of a fiber reinforced drillable bone cement for screw augmentation in a sheep model--mechanical testing.

Authors:  Benjamin J Ahern; Robert D Harten; Elliott A Gruskin; Thomas P Schaer
Journal:  Clin Transl Sci       Date:  2010-06       Impact factor: 4.689

Review 5.  Calvarial Reconstruction.

Authors:  Arvind Badhey; Sameep Kadakia; Moustafa Mourad; Jared Inman; Yadranko Ducic
Journal:  Semin Plast Surg       Date:  2017-10-25       Impact factor: 2.314

6.  A novel method of translabyrinthine cranioplasty using hydroxyapatite cement and titanium mesh: a technical report.

Authors:  Nicholas C Bambakidis; Charles Munyon; Alvin Ko; Warren R Selman; Cliff A Megerian
Journal:  Skull Base       Date:  2010-05

Review 7.  Frontal Sinus Fractures: Evolving Clinical Considerations and Surgical Approaches.

Authors:  Mark A Arnold; Sherard A Tatum
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2019-02-04

8.  Bone regeneration with glass ceramic implants and calcium phosphate cements in a rabbit cranial defect model.

Authors:  Gerlind Schneider; Karin Blechschmidt; Dirk Linde; Peter Litschko; Thomas Körbs; Eggert Beleites
Journal:  J Mater Sci Mater Med       Date:  2010-09-22       Impact factor: 3.896

Review 9.  Open Anterior Skull Base Reconstruction: A Contemporary Review.

Authors:  Daniel Kwon; Alfred Iloreta; Brett Miles; Jared Inman
Journal:  Semin Plast Surg       Date:  2017-10-25       Impact factor: 2.314

10.  Cranioplasty of Hemispherical Defects Using Calcium Phosphate Cements Along with Titanium Mesh: Our Experience.

Authors:  N Girish Kumar; S Sudeep; Rahul Balwan
Journal:  J Maxillofac Oral Surg       Date:  2015-03-21
View more